1. Introduction
The WeAct Studio Type-C PD/QC/AFC Fast Charge Trigger Module is designed to convert power from compatible USB-C fast chargers (supporting PD2.0/PD3.0, QC2.0/QC3.0, and AFC protocols) into fixed DC voltages. This module allows users to select a specific output voltage (5V, 9V, 12V, 15V, 20V) for various applications, such as powering development boards, small electronics, or acting as a power supply for notebooks that require specific DC inputs.
2. Product Overview
This module features a USB-C input port for connection to a fast charger and dedicated VCC and GND output pads for integration into your projects. Voltage selection is managed via a set of dip switches on the board.
3. Specifications
| Feature | Description |
|---|---|
| Brand Name | WeAct Studio |
| Accessory Type | USB To DC Cable (Module) |
| Compatible Protocols | PD2.0/PD3.0, QC2.0/QC3.0, AFC |
| Supported Output Voltages | 5V, 9V, 12V, 15V, 20V (fixed voltage output, voltage step not supported) |
| Battery Included | No |
| Typical Application Fields | Education and Learning |
| High-concerned chemical | None |
| Product Weight | 0.01 kg |
| Package Dimensions (L x W x H) | 3 cm x 4 cm x 3 cm |
4. Setup
Follow these steps to set up your fast charge trigger module:
- Connect Power Source: Connect a compatible USB-C fast charger (supporting PD2.0/PD3.0, QC2.0/QC3.0, or AFC protocols) to the Type-C input port on the module.
- Select Output Voltage: Use the three dip switches (labeled S1, S2, S3) on the module to select your desired output voltage. Refer to the voltage selection table below. A '1' indicates the switch is in the ON (up) position, and a '0' indicates the switch is in the OFF (down) position.
- Verify Voltage (Crucial Step): Before connecting any device, always use a multimeter to measure the voltage across the VCC and GND output pads to ensure the correct voltage is being output. The module does not have a built-in voltage indicator.
- Connect to Application: Once the voltage is verified, connect the VCC and GND output pads to your application circuit or device.
4.1. Wiring Diagram
4.2. Voltage Selection Table
Important Note:
- Since there is no voltage indicator after adjusting the dip switch, use a multimeter to measure the voltage before connecting to the application circuit.
- If the dip switch is not adjusted according to the table, the module may output an unintended voltage from the supported range. Always configure switches correctly.
5. Operation
Once the module is set up with the desired voltage and connected to a compatible USB-C fast charger, it will automatically negotiate the power delivery protocol to output the selected fixed DC voltage. The module is designed for continuous operation within its specified voltage and current limits, which are ultimately determined by the connected USB-C power source.
Ensure that the current draw of your connected device does not exceed the capabilities of your USB-C charger at the selected voltage. Overloading the charger or the module can lead to instability or damage.
6. Troubleshooting
- No Output Voltage:
- Ensure the USB-C charger is properly connected and powered on.
- Verify that your USB-C charger supports one of the compatible fast charging protocols (PD2.0/PD3.0, QC2.0/QC3.0, AFC).
- Check the dip switch settings against the voltage selection table (Figure 6) to ensure a valid voltage is requested.
- Use a multimeter to confirm if the charger is providing power and if the module is attempting to output.
- Incorrect Output Voltage:
- Double-check the dip switch settings carefully against the voltage selection table (Figure 6). A single incorrect switch position can lead to an unexpected voltage.
- Confirm that your USB-C charger is capable of supplying the requested voltage. Some chargers may not support all voltages (e.g., a 9V charger won't output 20V).
- Always use a multimeter to verify the actual output voltage before connecting your device.
- Module Not Responding:
- Try a different compatible USB-C charger.
- Inspect the module for any visible damage or loose connections.
7. User Tips
- Always Verify Voltage: Due to the lack of a voltage indicator, it is highly recommended to always use a multimeter to confirm the output voltage after setting the dip switches and before connecting any sensitive equipment. This prevents potential damage to your devices.
- Understand Power Limits: While the module requests a specific voltage, the maximum current (and thus wattage) it can deliver is limited by the capabilities of your connected USB-C power adapter. Ensure your power source can provide sufficient current at the desired voltage for your application.
- Stable Connections: Ensure all connections, especially to the VCC and GND pads, are secure and properly soldered if applicable, to avoid intermittent power delivery.
8. Maintenance
To ensure the longevity and reliable operation of your module, please observe the following maintenance guidelines:
- Keep Clean and Dry: Protect the module from dust, dirt, and moisture. Avoid using it in environments with high humidity or where it might come into contact with liquids.
- Avoid Extreme Conditions: Do not expose the module to extreme temperatures (very hot or very cold) or rapid temperature changes.
- Handle with Care: The module contains sensitive electronic components. Handle it gently to prevent physical damage to the board, components, or solder joints.
- Power Down Before Adjustments: Always disconnect the power source before making any adjustments to the dip switches or connecting/disconnecting devices to the output pads.
9. Warranty and Support
For any technical assistance, questions, or support regarding your WeAct Studio Type-C PD/QC/AFC Fast Charge Trigger Module, please contact the seller or manufacturer directly. Please provide your purchase details and a clear description of the issue to facilitate a quick resolution.