Introduction
The BEVOTOP 18GHz SS402 RF Coaxial Cable is a high-quality, low-loss test cable designed for high-frequency applications. It is suitable for use with various test equipment and network analyzers, providing reliable signal transmission up to 18GHz. These cables are available with different connector configurations, including SMA Male to SMA Male, N Male to SMA Male, and N Male to N Male, and come in a range of lengths to suit diverse requirements. The connectors are made from durable stainless steel, ensuring longevity and stable performance.

Figure 1: BEVOTOP 18GHz SS402 Cable (Example)
Setup
- Identify Connector Types: Determine the required connector types (SMA Male, N Male) for your specific application and equipment. The SS402 cables are available with various combinations.

SMA Male to SMA Male

N Male to SMA Male

N Male to N Male
- Inspect Connectors: Before connecting, visually inspect both the cable connectors and the equipment ports for any dust, debris, or damage. Clean if necessary using appropriate methods for RF connectors.
- Connect Securely: Carefully align the male connector on the cable with the female port on your device. Gently push the connector in and then hand-tighten the coupling nut until snug. Avoid overtightening, as this can damage the connectors.
- Cable Routing: Route the cable to avoid sharp bends, kinks, or placing it under heavy objects, which can degrade performance or damage the cable.
Operating Instructions
The SS402 RF Coaxial Cable is a passive component designed to transmit high-frequency signals. Proper operation involves ensuring compatibility with your connected devices.
- Compatibility Check: Verify that the impedance (50 Ohm) and frequency range (0-18GHz) of the cable match the requirements of your RF equipment (e.g., test equipment, network analyzers, antennas).
- Signal Transmission: Once connected, the cable will transmit RF signals between the connected devices. Monitor your equipment for expected signal integrity and performance.
- Testing Applications: When used with test equipment like a Network Analyzer, ensure the analyzer is properly calibrated for the frequency range and cable characteristics to obtain accurate measurements.

Figure 2: Network Analyzer connected to an SS402 cable during testing.
Maintenance
To ensure the longevity and optimal performance of your BEVOTOP SS402 RF Coaxial Cable, follow these maintenance guidelines:
- Cleaning Connectors: Regularly inspect and clean the connectors. Use a lint-free cloth and a small amount of isopropyl alcohol to gently wipe away any dust, dirt, or residue. Ensure connectors are dry before re-connecting.
- Avoid Physical Stress: Do not bend the cable sharply, twist it excessively, or pull on the cable itself when disconnecting. Always grasp the connector housing.
- Proper Storage: When not in use, coil the cable loosely and store it in a clean, dry environment away from extreme temperatures, direct sunlight, and corrosive substances. Use cable ties to keep it neatly organized.
- Inspect for Damage: Periodically check the cable jacket and connectors for any signs of wear, cuts, cracks, or corrosion. Damaged cables should be replaced to prevent signal degradation or equipment damage.
Troubleshooting
If you experience issues with your SS402 RF Coaxial Cable, consider the following:
- No Signal or Weak Signal:
- Ensure all connectors are securely tightened.
- Check for compatibility: Verify that the cable's impedance (50 Ohm) and frequency range (0-18GHz) match your equipment.
- Inspect the cable for visible damage (kinks, cuts, crushed sections).
- Test with a known good cable if available to isolate the issue.
- Intermittent Connection:
- Clean the connector contacts on both the cable and the equipment.
- Ensure the connectors are not loose.
- Check for any movement in the cable that might cause the connection to break.
- High VSWR or Signal Reflection:
- Verify that the cable is rated for the operating frequency.
- Ensure proper termination (e.g., 50 Ohm load) if required by your setup.
- Inspect connectors for damage or improper mating.

Figure 3: Example Network Analyzer test results showing VSWR and signal loss.
Specifications
| Attribute | Value |
|---|---|
| Brand Name | BEVOTOP |
| Model Number | BT1008-SS402 |
| Product Name | SS402 RF Coaxial Cable |
| Type | RF Connector Coaxial Cable Assembly |
| Connector Type A | N Type Male Plug (Stainless Steel) / SMA Male Plug (Stainless Steel) |
| Connector Type B | SMA Male Plug (Stainless Steel) / N Type Male Plug (Stainless Steel) |
| Connector Material | Stainless steel |
| RF Cable Type | SS402 50-3 Cable |
| Impedance | 50 Ohm |
| VSWR | Less than 1.2 |
| Max Frequency | 18GHz |
| Feature | Low Loss High Frequency Test Cable |
| Length Options | 15Cm, 20CM, 25CM, 30CM, 40CM, 50CM, 60CM, 70CM, 80CM, 90CM, 1M, 1.2M, 1.5M, 2M, 2.5M, 3M, 4M, 5M (or customized) |
| Application | Test Equipment, Network Analyzer |
| Customization | Yes |
Cable Construction Details

Figure 4: Construction Specification and Structural Parameters of SS402 Cable.
| Item | Material & Process | Diameter (mm) |
|---|---|---|
| Inner conductor | Silver plated copper | 0.92 ± 0.01 |
| Dielectric | PTFE | 2.99 ± 0.05 |
| Outer conductor | Spiral wrapped silver plated copper braiding | 3.19 ± 0.10 |
| Outer shield | Silver-Plated Copper Wire Braiding | 3.55 ± 0.05 |
| Jacket | FEP (blue) | 4.15 ± 0.05 |
User Tips
- Customization Options: BEVOTOP offers extensive customization for these cables. If your application requires specific cable types (e.g., RG316, RG58, LMR series) or different connector types (e.g., MCX, Fakra, TS9, CRC9), contact BEVOTOP for tailored solutions.
- Length Requirements: Cables can be customized to any length. Always measure your required length accurately to avoid excess cable, which can introduce unnecessary signal loss, or insufficient length, which can cause strain on connectors.
Warranty and Support
BEVOTOP is committed to providing high-quality RF coaxial connectors and cable assemblies. Our products are designed for various applications including data storage, networking, communications, automotive, medical, and aerospace.
In the event of any issues, please contact BEVOTOP customer support. We will address concerns regarding lost or damaged parcels during shipment, offering refunds or reshipment as appropriate.
For further assistance or inquiries, please refer to the BEVOTOP RF Cable Store online.