1. Introduction
The BENETECH GM100 Ultrasonic Thickness Gauge is an intelligent handheld device designed for quick and precise measurement of material thickness using ultrasonic principles. Controlled by a microprocessor, it is suitable for a wide range of industrial materials that conduct and reflect constant sonic velocity. This unit is extensively used in manufacturing, metal processing, and commercial inspection, particularly for monitoring thickness reduction in various pressure containers and hardware parts.
For additional information and a downloadable version, please refer to the official user manual (PDF).
2. Product Overview
The GM100 features a clear LCD display and intuitive button controls for ease of use. Its robust design ensures reliability in various industrial environments.
2.1 Components and Controls

Description: This diagram illustrates the main components of the GM100. Key features include the Receive and Transmit sockets for the probe, the LCD display, Adjust keys (up/down arrows), Sound Velocity (VEL) key, Store key, Calibration (CAL) key, ON/OFF key, Probe, and Calibration block.
- LCD Display: Shows thickness measurements, sound velocity, and other operational information.
- VEL Key: Used to select or adjust sound velocity.
- STORE Key: For storing and recalling measurement data.
- CAL Key: Initiates calibration and also functions as a backlight activation key.
- ON/OFF Key: Powers the device on or off.
- Adjust Keys (Up/Down): Used to navigate menus and adjust values.
- Probe: The transducer that emits and receives ultrasonic waves.
- Calibration Block: A standard block (typically 4mm steel) used for calibration.
3. Specifications
| Feature | Specification |
|---|---|
| Measuring Range | 1.2 - 225mm (Steel) |
| Accuracy | ±(1%H + 0.1)mm |
| Resolution | 0.1mm |
| Sound Velocity Range | 1000 - 9999m/s |
| Working Frequency | 5MHz |
| Minimum Limit for Tube Measurement | Φ20 x 3mm (Steel) |
| Auto Calibration | Yes |
| Data Store/Recall/Delete Function | Yes (10 measurements) |
| Sound Velocity Measurement | Yes |
| Low Battery Indication | Yes |
| Auto Power Off | Yes |
| LCD Backlight Display | Yes |
| Unit Size | 80 x 38 x 150mm |
| Power Supply | 3 x 1.5V AAA Batteries (Not Included) |
| Certification | CE |
3.1 Sound Velocities of Common Materials
| Material | Velocity (m/s) | Material | Velocity (m/s) |
|---|---|---|---|
| Aluminum | 6320 | Acetate resin | 2670 |
| Zinc | 4170 | Phosphor bronze | 3530 |
| Silver | 3600 | Turpentine | 4430 |
| Gold | 3240 | Glass | 5440 |
| Tin | 3230 | Incoloy alloy | 5720 |
| Iron/Steel | 5900 | Magnesium | 6310 |
| Brass | 4640 | Monel alloy | 6020 |
| Copper | 4700 | Nickel | 5630 |
| SUS | 5790 | Steel 4330 (mild) | 5850 |
| Acrylic resin | 2730 | Steel 330 | 5660 |
| Water (20°C) | 1480 | Titanium | 6070 |
| Glycerin | 1920 | Zirconium | 4650 |
| Soluble glass | 2350 | Nylon | 2620 |
4. Setup
4.1 Battery Installation
- Locate the battery compartment on the back of the device.
- Open the battery cover.
- Insert three 1.5V AAA batteries, ensuring correct polarity.
- Close the battery cover securely.

Description: This image shows the rear of the GM100 with the battery cover removed, revealing the three AAA battery slots.
4.2 Probe Connection
- Connect the probe cables to the Receive and Transmit sockets located at the top of the GM100 unit. Ensure a firm connection.

Description: An angled view of the GM100, clearly showing the two probe cables connected to the top of the device.
4.3 Coupling Agent
A coupling agent (gel) is essential for accurate ultrasonic measurements as it ensures proper transmission of ultrasonic waves between the probe and the material being measured. The coupling agent is not included due to shipping restrictions on paste-like substances. Suitable alternatives include dishwashing liquid, shampoo, or shower gel.
5. Operation
Watch the operation demonstration video for a visual guide:
Description: This video demonstrates the boot display interface, steel block measurement, glass thickness measurement, resin material thickness measurement, calibration block test, self-calibration operation, speed of sound selection test, and sound velocity value measurement settings.
5.1 Power On/Off
Press the ON/OFF key to turn the device on or off. The device has an auto power-off feature to conserve battery life.
5.2 Basic Measurement
- Ensure the device is powered on and calibrated (see Section 5.3).
- Apply a small amount of coupling agent to the surface of the material where you intend to measure.
- Place the probe firmly and flatly onto the couplant-applied surface.
- The thickness measurement will be displayed on the LCD. Observe the coupling icon to ensure proper contact.
5.3 Calibration
Auto calibration ensures measurement accuracy. It is recommended to calibrate the device before use, especially when measuring different materials or if accuracy is critical.
- Place the probe onto the provided 4mm steel calibration block with coupling agent.
- Press the CAL key. The device will perform self-calibration.
- Once calibration is complete, the display will show the calibrated thickness (e.g., 4.0mm).
5.4 Sound Velocity Selection
The GM100 has 12 built-in common sound velocity values for different materials. To select a sound velocity:
- Press the VEL key.
- Use the Adjust (Up/Down) keys to cycle through the pre-set sound velocities.
- Once the desired sound velocity for your material is displayed, press VEL again to confirm.
5.5 Sound Velocity Measurement (for unknown materials)
If the sound velocity of a material is unknown, you can measure it if you have a sample of known thickness:
- Measure the thickness of your sample using a caliper or other precise method.
- Enter this known thickness into the GM100 using the appropriate function (refer to the full PDF manual for detailed steps).
- Apply coupling agent and place the probe on the sample. The device will then calculate and display the sound velocity for that material.
5.6 Data Storage and Recall
The device can store up to 10 thickness measurements.
- To Store: After a measurement, press the STORE key to save the reading.
- To Recall: Press the STORE key repeatedly to cycle through stored measurements.
- To Delete: Refer to the full PDF manual for specific instructions on deleting stored data.
6. Maintenance
- Cleaning: Wipe the device and probe with a soft, dry cloth after each use. Avoid using abrasive cleaners or solvents.
- Storage: Store the GM100 in its protective case in a dry, cool place when not in use. Remove batteries if storing for extended periods.
- Coupling Agent: Ensure no residue from the coupling agent remains on the probe or measurement surface after use.
- Battery Replacement: Replace batteries promptly when the low battery indicator appears on the display to ensure accurate readings and prevent device malfunction.
7. Troubleshooting
- No Reading / Erratic Readings:
- Check if sufficient coupling agent is applied.
- Ensure the probe is placed firmly and flatly on the surface.
- Verify the material's sound velocity setting is correct.
- Check for surface irregularities or coatings that might interfere with ultrasonic transmission.
- Low Battery Indicator: Replace the AAA batteries immediately.
- Device Not Powering On: Check battery installation and ensure batteries are fresh.
- Inaccurate Readings: Perform a calibration using the provided 4mm steel block.
8. User Tips
- Wood Thickness Measurement: This ultrasonic thickness gauge is designed for materials that conduct and reflect constant sonic velocity, such as metals, glass, and certain plastics. It is generally not suitable for measuring the thickness of wood due to wood's fibrous, non-homogeneous structure, which can cause inconsistent ultrasonic wave propagation and inaccurate readings.
- Coupling Agent Alternatives: As the specialized coupling agent is not included, common household items like dishwashing liquid, shampoo, or shower gel can serve as effective alternatives for ensuring good acoustic coupling between the probe and the test material.
- Surface Preparation: For best results, ensure the measurement surface is clean, smooth, and free of rust, paint, or other coatings that could interfere with the ultrasonic signal.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or refer to the official product documentation. Keep your purchase receipt as proof of purchase.