1. Introduction and Overview
The JUNCTEK KG-F series voltage and current meter is a versatile coulometer designed for precise monitoring of various electrical parameters. It accurately measures DC voltage, current, power, charge and discharge Ampere-hour (AH) values, watt-hours, time, and temperature. This device features a color LCD screen for real-time data display and battery capacity monitoring.
Key functionalities include multi-protection settings (over-voltage, under-voltage, over-current, over-power, over-temperature, and time limit protection), automatic current direction identification, and mobile APP control with real-time firmware updates. The mobile APP also provides voltage and current curve displays and data export capabilities.

Figure 1.1: JUNCTEK Battery Monitor with Display, Measuring Module, and Shunts
Video 1.1: JUNCTEK KG-F Series Product Overview
2. Safety Information
Please read and understand the following safety precautions before operating the meter to prevent personal injury or damage to the device.
General Safety Summary
- Observe All Terminal Ratings: To avoid fire or shock hazards, always adhere to the specified ratings and markers on the meter.
- Use Proper Over-voltage Protection: Ensure the product is protected from over-voltage events, such as lightning strikes, to prevent electric shock.
- Do Not Operate Without Covers: Never operate the meter with its covers or panels removed.
- Do Not Insert Anything Into the Air Outlet: Avoid inserting objects into the air outlet to prevent damage.
- Avoid Circuit or Wire Exposure: Do not touch exposed junctions or components when the unit is powered on.
- Do Not Operate With Suspected Failures: If any damage is suspected, have the meter inspected by JUNCTEK authorized personnel before further use. Repairs must be performed by authorized personnel only.
- Provide Adequate Ventilation: Ensure the meter is well-ventilated to prevent overheating. Regularly inspect the air outlet and fan.
- Do Not Operate in Wet Conditions: To prevent short circuits or electric shock, do not operate the meter in a humid environment.
- Do Not Operate in an Explosive Atmosphere: Never operate the meter in an explosive environment.
- Keep Meter Surfaces Clean and Dry: Maintain clean and dry surfaces to prevent dust or moisture from affecting performance.
- Prevent Electrostatic Impact: Operate the meter in an electrostatic discharge protective environment. Ground all internal and external conductors before making connections.
- Handle with Caution: Handle the device carefully during transportation to avoid damage to keys, knobs, interfaces, and other parts.
Important Notices
- Do not exceed the specified voltage and current range to prevent damage to the meter.
- Ensure correct polarity; positive and negative poles cannot be reversed.
- The meter's shell is fragile; avoid impacts and exposure to chemicals.
- Store the meter in a dry environment with a temperature range of -25°C to 50°C.
- Do not attempt to disassemble the meter, as this will void the warranty. There are no user-serviceable parts.
- The display screen is fragile; avoid touching or bumping it. Clean with a soft cloth if dirty.
- Do not move the meter violently to prevent internal circuit damage. Contact the supplier if the meter malfunctions.
3. Package Contents
Upon receiving your KG-F series coulometer, please inspect the packaging and contents carefully. If any items are damaged or missing, contact your JUNCTEK sales representative.

Figure 3.1: KG110F Shipping List Components

Figure 3.2: KG140F Shipping List Components

Figure 3.3: KG160F Shipping List Components
| Item | Description | Quantity |
|---|---|---|
| Host | KG-F series Display Module | 1 pc |
| Host | KG-F series Measuring Module | 1 pc |
| Host | KG-F series Sampler (Shunt) | 1 pc |
| Accessory | 3m Communication Cable | 1 pc |
| Accessory | Temperature Sensor | 1 pc |
| Accessory | 4P Connection Cable | 1 pc |
| Accessory | 3P Connection Cable (external relay cable) | 1 pc |
| Accessory | Terminal | 1 pc |
| Accessory | Quick Guide | 1 pc |
4. Product Dimensions

Figure 4.1: Display and Measuring Module Dimensions

Figure 4.2: KG110F Shunt Dimensions

Figure 4.3: KG140F Shunt Dimensions

Figure 4.4: KG160F Shunt Dimensions
5. Technical Specifications

| Parameter | KG110F | KG140F | KG160F |
|---|---|---|---|
| Sampling method | Shunt | ||
| Voltage measurement range (External power supply) | 0-120V | ||
| Voltage measurement range (Self-powered) | 10-120V | ||
| Voltage resolution | 0.01V | ||
| Current measurement range | 0-100A | 0-400A | 0-600A |
| Current resolution | 0.01A | 0.1A | 0.1A |
| Relay | Optional | ||
| Temperature measurement range | -20-120°C | ||
| Capacity display range | 0%-100% | ||
| Power measurement range | 0-72KW | ||
| Power resolution | 0.01W | ||
| AH measurement range | 0-9999.99AH | ||
| Capacity resolution | 0.001AH | ||
| Watt-hour measurement range | 0-9999.99kWH | ||
| Watt-hour accuracy | 0.001WH | ||
| Time measurement range | 0-999:59:59S | ||
| Time resolution | 1 second | ||
| Bluetooth communication distance | 10m | ||
| Voltage accuracy | ±1%+2 digits | ||
| Current accuracy | ±1%+5 characters | ||
| Sampling rate | 1 time / second | ||
| Measuring module power consumption | About 0.4W | ||
| Display module power consumption | About 0.5W | ||
| Over power protection | 0-99999.99W | ||
| Negative over current protection | 0-50A/100A/400A/600A | ||
| Forward over current protection | 0-50A/100A/400A/600A | ||
| Overvoltage protection | 0-120V/600V | ||
| Undervoltage protection | 0-120V/600V | ||
| External over temperature protection | 0-120°C | ||
| Protection recovery time | 0-99s | ||
| Enter standby time | 0-60s | ||
| Delay time setting | 0-99S | ||
| Mailing address | 99 P01-P99, P00 is the broadcast address | ||
Model Differences (KL, KG, KH Series)
| Feature | KL | KG | KH |
|---|---|---|---|
| 2.4 In Display Screen | No | Yes | Yes |
| Shunt Housing | No | No | Yes |
| Protection Sound Alarm | No | No | Yes |
| Temperature Display | Celsius | Celsius | Fahrenheit or Celsius |
| Display Time | No | No | Local Time |
| Bluetooth password | No | No | Support Modification |
| Voltage current curve | Yes | Yes | Yes |
| Data Record | Yes | Yes | Yes |
| Mobile APP | Yes | Yes | Yes |
| RJ9 Data Cable Length | No | 3 meters | 5 meters |
6. Installation and Wiring
This section details the wiring methods for the JUNCTEK KG-F series battery monitor. Ensure all connections are secure and correct to prevent damage.
Wiring Instructions Video
Video 6.1: Wiring Instructions
6.1 Self-Powered Wiring Method
This method is suitable if the tested battery's voltage is between 10-120V during normal operation.
- Set the power supply selection switch to "2W".
- Connect the positive terminal of the battery to the "Vsns" power supply interface. A 13-16AWG wire is sufficient.
- Connect the negative pole of the battery to the screw with "BATT-" on the sampler.
- Connect the negative poles of the charger and the load to the other screw of the sampler. Use a copper nose for a firm connection.
Note: Pay close attention to polarity; do not connect incorrectly or reverse connections. When charging, the current direction symbol is red, and remaining capacity increases. When discharging, the symbol is sky blue, and remaining capacity decreases.

Figure 6.1: Self-Powered Wiring Diagram
6.2 External Power Supply Wiring Method (Relay Control)
This method is used when the measuring voltage range of the external power supply is 0-120V and you wish to control charging or discharging via a relay.
- Set the power selection interface switch to "3W".
- Connect the positive pole of the external power supply to the "VEXT" power interface.
- Connect the negative pole of the external power supply to "GND".
- Connect the positive pole of the battery to the "Vsns" measurement interface.
- Connect the control ports of the relay to the "OUT" and "VEXT" of the measuring module's Output Control.
- Connect the positive pole of the external power supply to the "VEXT" of the Output Control, and the negative pole of the external power supply to the "GND".
Note: The external power supply voltage for the relay must match the relay's working voltage (e.g., 12V or 24V). Ensure correct polarity for all connections. When the relay is closed, the indicator light will be on; when disconnected, it will be off.

Figure 6.2: External Power Supply Wiring Diagram (Relay Control)
7. Display Interface Overview
The 2.4-inch TFT color LCD screen displays various parameters and settings. The following table and diagram explain the interface elements.

Figure 7.1: Accurate Measuring Parameters Display

Figure 7.2: Product Views of Display Module
| Item | Description |
|---|---|
| 1 | Key lock status |
| 2 | Output status and data record |
| 3 | Communication address |
| 4 | External temperature |
| 5 | Running time |
| 6 | Communication signal indication |
| 7 | Power |
| 8 | Elapsed electric energy |
| 9 | Current direction |
| 10 | Battery remaining capacity |
| 11 | Battery internal resistance |
| 12 | Battery life |
| 13 | Elapsed AH value |
| 14 | Remaining AH value |
| 15 | Measured current value |
| 16 | Measured voltage value |
8. System Settings
Access system settings by short pressing the [SET] button from the main interface. Use the [▲] and [▼] buttons to navigate and adjust values, and [OK] to confirm.
System Settings Video
Video 8.1: System Settings Tutorial
8.1 Language Selection
Navigate to "Language" in settings. Press [OK], then use [▲]/[▼] to select between Chinese and English. Confirm with [OK].
8.2 Set Current to Zero
Navigate to "Set current to zero". Press [OK]. A pop-up window will appear. Use [▲]/[▼] to select "OK" and confirm with [OK]. This calibrates the current to 0A.
Important: After first startup or factory reset, if the meter shows a small current deviation without load, it will automatically calibrate for about 30 seconds. Press and hold [OK] to confirm the zero state.
8.3 Clear Accumulated Data
Navigate to "Clear Data". Press [OK]. A pop-up window will appear. Use [▲]/[▼] to select "OK" and confirm with [OK]. This clears time, watt-hour, and elapsed AH values.
8.4 Preset Battery AH Value
Navigate to "AH. preset". Press [OK]. Use [▲]/[▼] to adjust the value. Press [OK] to switch digit positions. Confirm with [OK] to save.
For first-time battery use:
- Discharge the battery until empty (0% power).
- Set the preset battery capacity to a value slightly higher than estimated (e.g., 20Ah to 30Ah).
- Set the remaining capacity percentage to 0%.
- Fully charge the battery.
- After full charge, check the displayed remaining capacity and set this value as the new preset battery capacity.
8.5 Percentage of Remaining AH Value
Navigate to "AH. remaining". Press [OK]. Use [▲]/[▼] to adjust the percentage (0-100%). Press [OK] to switch digit positions. Confirm with [OK] to save.
The remaining AH value graph is red if ≤ 20% and green if > 20%. For accuracy, set to 100% for full charge and 0% for full discharge.
8.6 Screen Brightness
Navigate to "Brightness". Press [OK]. Use [▲]/[▼] to adjust brightness (1%-100%). Confirm with [OK].
8.7 Protection Functions
The meter offers comprehensive protection features. For these to function effectively, a relay must be purchased separately and installed in the circuit. If no relay is installed, set protection values to 0 to disable the function.

Figure 8.1: Comprehensive Protection Features
- Under-voltage Protection (LVP): Navigate to "LVP". Press [OK]. Adjust the voltage value. If the current voltage falls below this value, LVP will display, and the meter will stop calculating capacity.
- Over-voltage Protection (OVP): Navigate to "OVP". Press [OK]. Adjust the voltage value. If the current voltage exceeds this value, OVP will display, and the meter will stop calculating capacity.
- Positive Over-current Protection (OCP): Navigate to "OCP". Press [OK]. Adjust the current value. If the discharge current exceeds this value, OCP will display, and the meter will stop calculating capacity.
- Negative Over-current Protection (NCP): Navigate to "NCP". Press [OK]. Adjust the current value. If the charging current exceeds this value, NCP will display, and the meter will stop calculating capacity.
- Over Power Protection (OPP): Navigate to "OPP". Press [OK]. Adjust the power value. If the current power exceeds this value, OPP will display, and the meter will stop calculating capacity.
- Over Temperature Protection (OTP): Navigate to "OTP". Press [OK]. Adjust the temperature value. If the ambient temperature exceeds this value, OTP will display, and the meter will stop calculating capacity.
- Low Temperature Protection (LTP): This feature is crucial for LiFePO4 batteries. Navigate to "LTP". Press [OK]. Adjust the temperature value. If the temperature falls below this value, LTP will display.
8.8 Reverting Time Protection
Navigate to "Revert time". Press [OK]. Adjust the time value. If set to 00s, protection continues until [OK] is pressed. If set to >00s (e.g., 5s), protection automatically cancels after the set time once values return to normal.
8.9 Enter Standby Time
Navigate to "Standby Time". Press [OK]. Adjust the time value. 0 = normally on. 1-60s = screen off after inactivity. Automatic = screen off after 20s of 0 current.
8.10 Calibrations (Voltage, Current, Temperature)
Navigate to "Voltage Cal.", "Current Cal.", or "Temp. Cal." respectively. Press [OK]. Adjust the calibration value (e.g., ±10% for voltage, ±25% for current). Confirm with [OK]. These can be performed online.
8.11 Set Address
Navigate to "Address". Press [OK]. Adjust the communication address (P01-P99, P00 for broadcast). Confirm with [OK]. This is used for multi-machine communication.
8.12 Set Delay Time
Navigate to "Delay Time". Press [OK]. Adjust the delay time (0-99S). Confirm with [OK]. This sets how long the meter waits before entering protection state after a value exceeds the set limit.
8.13 Current Ratio (for Hall sensor version)
Navigate to "Current ratio". Press [OK]. Adjust the ratio (default X01). This is used when the Hall sensor wire is wound multiple times to measure small currents.
8.14 Monitor Function
Navigate to "Monitor function". Press [OK]. Use [▲]/[▼] to switch ON/OFF. Must be ON for computer software control. When ON, display module settings are limited.
8.15 Relay Mode
Navigate to "Relay Mode". Press [OK]. Use [▲]/[▼] to select "NO" (Normally Open) or "NC" (Normally Closed) based on your relay type. Confirm with [OK].
8.16 Restore Factory Settings
Navigate to "Restore factory settings". Press [OK]. A confirmation box will appear. Select "OK" and confirm with [OK].
9. Mobile APP Control
The mobile APP allows for wireless control and monitoring of the battery monitor via Bluetooth. It supports Android and iOS devices.
APP Installation and Operation Video
Video 9.1: Mobile APP Control Tutorial
9.1 APP Download
- Android: Download from Google Play Store by searching for "juntek.vat" or directly from the server link: http://68.168.132.244/app/KG.apk.
- iOS: Search for "KG Series" in the Apple App Store.
9.2 APP Connection
- Open the APP and click "Search" in the upper right corner.
- Select the corresponding Bluetooth device (e.g., BTG001).
- The interface will show "Connected", and the meter model will appear, indicating a successful connection.
9.3 Main Interface Operations

Figure 9.1: Mobile APP Main, Curve, and Settings Interfaces
- Output State Control: Click the switch to control the output state. Different states are displayed under various protection conditions.
- Voltage/Current Calibration: Click on the voltage or current value to open the calibration pop-up. Enter the corresponding value for fine-tuning and click OK.
- Voltage/Current Range: Click on the voltage/current dial to adjust the maximum scale value.
- Zero Current: When the load is 0, click the zero current button to memorize the current in this state.
- Clear Data: Click the clear data button to reset time, watt-hour, and cumulative capacity.
- Remaining Capacity Percentage: Click the battery icon to input and set the remaining capacity percentage.
- Preset Battery AH Value: Click the setting button next to the preset battery AH value to input and set the value.
- Ambient Temperature: Click the ambient temperature icon to input and set the external temperature calibration.
- Temperature Unit Switching: Click the ambient temperature value to switch between Celsius and Fahrenheit.
9.4 Curve Interface Operations
- Real-time Curve: Displays real-time voltage and current curves. Ensure output state and data recording are ON.
- History Curve: Click "History: OFF" to turn ON. View historical voltage and current curves, and slide to navigate through historical data.
- Export Curve: When viewing history curves, an "Export curve" button appears. Click to generate an Excel file with voltage and current values at specific times.
- Custom Viewing Curve: Select a time range to view specific sections of the history curve.
9.5 Firmware Upgrade
- In the after-sales service interface, click "Firmware Upgrade".
- Enter the firmware code "000" and click OK.
- The instrument will begin upgrading, indicated by rapid flashing of the measurement module's indicator light.
- Wait patiently for the upgrade to complete. The message "Upgrade Successful" will be displayed.
Note: Do not exit the APP or power off the device during the upgrade process. If your device was ordered before January 1, 2022, you may need to power off the product, short-circuit the temperature measurement interface, then power on and proceed with the upgrade.
9.6 Extended Service
In the after-sales service interface, click "Extended service". Enter the password "0000" and click OK to access advanced settings. Use with caution and only if you understand the full voltage, current, and power deficit settings.
9.7 Other APP Functions
- Restore Factory Settings: In the after-sales service interface, click "Restore Factory Settings" and confirm.
- Restart Machine: In the after-sales service interface, click "Restart machine" and confirm.
- Detection Time: Input a value (0-20min) for detection time.
- Full Voltage: Input the full voltage (0-120V).
- Power Loss Voltage: Input the power loss voltage (0-120V).
- Full Current: Input the full current (0-20%).
10. Troubleshooting
This section addresses common issues and provides solutions for the KG-F series. If problems persist, contact JUNCTEK support.
- Screen is black after power on:
- Check power wiring and connections between display and main board.
- Restart the meter after checking connections.
- If still not working, contact JUNCTEK.
- Screen display is too dark:
- Check brightness setting in system settings.
- Press [SET], navigate to "Brightness" using [▲]/[▼], press [OK], then adjust brightness with [▲]/[▼] and confirm with [OK].
- No WiFi connection: The device uses Bluetooth, not WiFi, for wireless communication.
- Cannot find iOS app: Search for "KG Series" in the Apple App Store.
- Bluetooth reception issues: Try to reduce the distance between the display module and the shunt for better Bluetooth reception.
11. User Tips
- Display Backlight: To turn off the display backlight, press the Up and Down buttons simultaneously.
- Battery Compatibility: The controller is compatible with various battery types, including LiFePO4, and accurately measures capacity based on Ampere-hours.
- Shunt Upgrades: If you purchase a 100A variant, you can later buy a higher amperage shunt (e.g., 400A) separately and use it with your existing display and measuring module.
- Low Temperature Protection (LTP): For LiFePO4 batteries, ensure the Low Temperature Protection feature is configured correctly to prevent damage in cold conditions.
- Data Transfer: The mobile app allows for viewing real-time and historical data curves, and supports exporting historical data to Excel files for records.
12. Warranty and Support
JUNCTEK products are covered by P.R.C. patents. This document replaces all previously published documentation.
Contact Information
- E-mail: junce@junteks.com
- Website: www.junteks.com
Additional Resources
- Full User Manual (PDF): https://manuals.plus/m/03ec4b39626e3e8f4a8042cef3686b48b8f9b35f5bf0a7cfbb64d2f6c6f0b3b2
- Firmware Upgrade Log (PDF): https://manuals.plus/m/edf3d491cea2a71a436e0abdbcf617b3d7a22cdf6838b8fc8f2ca866e89f1aca