1. Introduction
The ELECTESLA P300 series precision pressure transducer is designed for high-accuracy measurement in a wide range of industrial applications. Constructed from stainless steel and featuring high-quality pressure sensing elements, this transmitter offers reliable performance. Its special circuits allow for convenient adjustment of zero and full range. This pressure transmitter is suitable for various applications in process control, laboratory settings, and materials testing equipment.
2. Safety Information
- Always read and understand this manual before installation and operation.
- Ensure the power supply matches the device specifications (DC12V; DC24V).
- Do not exceed the maximum specified pressure range.
- Verify compatibility of the transmitter's materials (304 Stainless Steel) with the measured medium (liquid, gas, steam, oil, etc.) to prevent corrosion or damage.
- Installation and wiring should be performed by qualified personnel in accordance with local electrical codes and safety standards.
- Avoid exposing the device to temperatures outside its operating range (-40-85℃).
3. Product Overview and Features
The P300 Pressure Transmitter is a robust and versatile sensor with the following key features:
- CE Conformity: Meets European safety, health, and environmental protection requirements.
- Durable Construction: All stainless steel integrated structure (304 Stainless Steel housing material).
- Compact Design: Small size for convenient installation and operation in various setups.
- Versatile Output: Supports multiple output signals including 4-20mA, 1-5V, 0-5V, 0-10V, and RS485.
- Wide Application: Suitable for measuring pressure in air, water, oil, and other media.
- High Precision: Features 0.2%FS high precision with strong anti-interference capabilities.
- Instantaneous Response: Imported diffusion silicon chip provides 8ms instantaneous response.
- Long-term Stability: Linearity ≤0.01%FS and stability ≥10 years.
- Anti-damping Design: Resistant to 300% instantaneous impact.

Figure 1: P300 Pressure Transmitter with key specifications.

Figure 2: Internal components and features of the P300 Pressure Transmitter.
4. Specifications
| Attribute | Value |
|---|---|
| Model Number | ES-P300 |
| Brand Name | ELECTESLA |
| Max Measuring Range | 400 Bar & Above |
| Measuring Range | -1-0-1000bar |
| Output Signal | 4-20mA, 0-10V, 0.5-4.5V or 0-5V or 1-5V, RS485 |
| Power Supply | DC12V; DC24V |
| Accuracy | C |
| Operating Temperature | -40-85℃ |
| Housing Material | 304 Stainless Steel |
| Thread | G1/4, G1/2, M20-1.5 |
| Battery Included | No |
| High-concerned chemical | None |
| Certification | CE, FCC, RoHS |
| Item | Pressure transmitter 4 20ma |
5. Setup
5.1. Unpacking
Carefully remove the pressure transmitter from its packaging. Inspect the device for any visible damage that may have occurred during transit. Ensure all components, including the transmitter and any supplied connectors, are present.
5.2. Mounting
The P300 Pressure Transmitter features standard industrial threads for easy installation. Available thread types include M20x1.5, G1/2, G1/4, and NPT1/4. Select the appropriate thread for your application. Ensure a proper seal is achieved to prevent leaks, using thread sealant or tape as necessary. Mount the transmitter securely in the desired location, ensuring it is protected from excessive vibration or physical impact.
5.3. Wiring
The transmitter requires a DC power supply (DC12V or DC24V) and provides various output signals. The wiring configuration depends on the chosen output signal. A common 4-wire configuration is shown in the video below. Always refer to the specific product label on your transmitter for exact wiring details, as color codes can vary.
Video 1: Demonstration of the Herssman Pressure Transmitter, including physical features, thread types, and wiring connections. Note: The video shows a 4-wire setup (blue, red, yellow, green) for general reference.
General Wiring Guidelines (Consult product label for specifics):
- Power Supply: Connect the positive (+) terminal of your DC power supply to the transmitter's power input (e.g., Red wire). Connect the negative (-) terminal of your DC power supply to the transmitter's ground (e.g., Blue wire).
- Signal Output: Connect the signal output wires to your receiving device (e.g., PLC, display, data logger). For 4-20mA output, connect the signal positive (e.g., Yellow wire) and signal negative (e.g., Green wire) to the corresponding inputs on your device. For voltage outputs (0-5V, 0-10V), connect the signal wire (e.g., Yellow wire) and ground (e.g., Green wire). For RS485, connect the A and B data lines.
6. Operating Instructions
Once the transmitter is correctly installed and wired:
- Apply Power: Turn on the DC power supply.
- Monitor Output: Observe the output signal on your connected device. The output should correspond to the measured pressure within the specified range.
- Verify Readings: Compare the readings from the transmitter with a known reference pressure if possible, especially during initial setup, to ensure accuracy.
- Adjustments: If necessary, use the convenient zero and full-range adjustment features (if applicable to your specific model) to fine-tune the output.
7. Maintenance
- Regular Inspection: Periodically check the transmitter for any signs of physical damage, corrosion, or loose connections.
- Cleaning: Keep the exterior of the transmitter clean. Use a soft, damp cloth. Do not use abrasive cleaners or solvents that could damage the housing or seals.
- Connection Integrity: Ensure all electrical and pressure connections remain tight and free from leaks.
- Recalibration: While the device boasts long-term stability, periodic recalibration may be necessary depending on the application's accuracy requirements and environmental conditions. Consult a qualified technician for calibration services.
8. Troubleshooting
8.1. No Output or Incorrect Readings
- Check Power: Verify that the correct DC power (12V or 24V) is supplied to the transmitter and that connections are secure.
- Inspect Wiring: Ensure all wires are correctly connected according to the product label and that there are no breaks or shorts in the cable.
- Verify Pressure Range: Confirm that the measured pressure falls within the transmitter's specified operating range (-1 to 1000 bar).
- Media Compatibility: Ensure the measured medium is compatible with the 304 Stainless Steel housing. Incompatible chemicals can damage the sensor.
- Check Receiving Device: Ensure the device receiving the signal (e.g., PLC, multimeter) is correctly configured and functioning.
8.2. Unstable Readings
- Check for Vibration: Excessive vibration can affect readings. Ensure the transmitter is securely mounted.
- Pressure Fluctuations: Rapid changes in process pressure can cause unstable readings. Consider adding a dampener if necessary.
- Electrical Interference: Ensure the wiring is properly shielded and routed away from sources of strong electromagnetic interference.
9. User Tips
- Wide Range Capability: The P300 Pressure Transmitter supports a broad measuring range from -1 to 1000 bar, making it suitable for diverse applications from vacuum to high pressure.
- Chemical Compatibility: The transmitter's housing is made of 304 Stainless Steel. For specific chemical applications, such as anhydrous ammonia (NH3) at elevated temperatures (e.g., 80°C), it is crucial to verify the compatibility of 304 Stainless Steel with the chemical under the operating conditions. The product is listed as having 'None' for 'High-concerned chemical', suggesting it may not be universally compatible with aggressive substances.
- Temperature Limits: The operating temperature range is -40°C to 85°C. Using the transmitter outside this range, for example, at 150°C, is not recommended and may lead to inaccurate readings or device failure.
10. Warranty and Support
The ELECTESLA P300 Pressure Transmitter comes with a 24-month warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For warranty claims, technical support, or any inquiries, please contact your vendor or the ELECTESLA Official Store directly. Please have your purchase details and model number (ES-P300) ready when contacting support.
11. Application Examples
The P300 Pressure Transmitter is ideal for a variety of industrial and commercial uses, including:
- Intelligent IoT constant pressure water supply systems
- Engineering machinery and industrial process control and monitoring
- Energy and water treatment systems
- Applications in steel, light industry, and environmental protection
- Medical equipment, agricultural machinery, and testing equipment
- Flow measurement systems
- Hydraulic and pneumatic control systems
- Air-conditioning units and refrigeration equipment
- Water pump and air compressor pressure monitoring

Figure 3: Diverse applications of the P300 Pressure Transmitter.