1. Product Overview
The INVT GD10 series is a mini economical Variable Frequency Drive (VFD) designed for various industrial applications. It offers reliable motor control with a compact design and essential features for efficient operation.
Key Features:
- SVPWM control for precise motor operation.
- Compact design for space-saving installation.
- Built-in PID controller with 16-step speed control.
- Standard potentiometer and external LED keypad for user interface.
- Optional C3 and C2 filters for EMC compliance.
- Natural cooling for single-phase or three-phase 220V 0.2-0.75kW models.
- CE certified, ensuring compliance with European safety standards.
Applications:
This VFD is suitable for a wide range of applications including:
- Packing machinery
- Food processing equipment
- Textile machinery
- Centrifugal machinery
- Carving machinery
- Wire cutting machines
Product Demonstration:
Video: Overview and physical features of the INVT GD10 VFD.
2. Specifications
The INVT GD10 series VFD offers various models with different power ratings and input voltages. Below are the detailed specifications:

Image: Detailed technical specifications for the INVT GD10 VFD.
| Function | Specification |
|---|---|
| Power Input | |
| Input Voltage (V) | Single-phase 220V (-15% to +10%) Three-phase 380V (-15% to +10%) |
| Input Current (A) | Refer to 2.5 |
| Input Frequency (Hz) | 50Hz or 60Hz (Allowed range: 47-63Hz) |
| Power Output | |
| Output Voltage (V) | Equal to input voltage (error < 5%) |
| Output Current (A) | Refer to 2.5 |
| Output Power (kW) | Refer to 2.5 |
| Output Frequency (Hz) | 50Hz/60Hz, fluctuation: ±5% |
| Technical Control | |
| Control Mode | SVPWM |
| Maximum Output Frequency | 400Hz |
| Adjustable-Speed Ratio | 1:100 |
| Overload Capability | 150% of rated current: 1 minute 180% of rated current: 10 seconds 200% of rated current: 1 second |
| Key Functions | Stop mode and anti-overtemperature of the bus |
| Temperature Measurement Accuracy | Overtemperature point ±3°C |
| Peripheral Interface | |
| Terminal Switch Input Resolution | ≤ 2ms |
| Terminal Analog Input Resolution | ≤ 20mV |
| Analog Input | 1 input 0-10V/0-20mA |
| Analog Output | 1 output 0-10V/0-20mA |
| Digital Input | 5 common input |
| Digital Output | 1 Y output (commonly used with digital output) and 1 programmable relay output |
| Communication | 485 communication |
| Running Control | |
| Frequency Setting | Digital setting, analog setting, multi-step speed setting, PID setting, MODBUS communication setting, etc. Switch between different settings. |
| Automatic Voltage Adjustment | Keeps output voltage stable when the grid voltage changes. |
| Fault Protection | More than 10 fault protections |
| Other | |
| Mountable Method | Wall mountable |
| Running Environment Temperature | -10~50°C (If temperature is above 40°C, derate 1% for every additional 1°C) |
| Cooling | Single-phase 220V 0.2-0.75kW: Natural cooling Single/three-phase 220V 1.5-2.2kW, three-phase 380V 0.75-2.2kW: Fan cooling |
| Pollution Degree | 2 |
| Braking Unit | Embedded |
| Braking Resistor | Not optional |
| EMC Filter | Optional and external (Optional C3 or C2 filter) |
Physical Dimensions:

Image: Diagram showing the physical dimensions (W1, W2, H1, H2, D) of the INVT GD10 VFD models.
| Model | W1 | W2 | H1 | H2 | D |
|---|---|---|---|---|---|
| Single-phase 220V | |||||
| GD10-0R2G-S2-B | 85.0 | 74.0 | 145.5 | 131.5 | 134.2 |
| GD10-0R4G-S2-B | 85.0 | 74.0 | 145.5 | 131.5 | 134.2 |
| GD10-0R7G-S2-B | 85.0 | 74.0 | 145.5 | 131.5 | 153.2 |
| GD10-1R5G-S2-B | 100.0 | 89.0 | 170.5 | 154.0 | 153.2 |
| GD10-2R2G-S2-B | 100.0 | 89.0 | 170.5 | 154.0 | 153.2 |
| Three-phase 220V | |||||
| GD10-0R2G-2-B | 85.0 | 74.0 | 145.5 | 131.5 | 134.2 |
| GD10-0R4G-2-B | 85.0 | 74.0 | 145.5 | 131.5 | 134.2 |
| GD10-0R7G-2-B | 85.0 | 74.0 | 145.5 | 131.5 | 153.2 |
| GD10-1R5G-2-B | 100.0 | 89.0 | 170.5 | 154.0 | 153.2 |
| GD10-2R2G-2-B | 100.0 | 89.0 | 170.5 | 154.0 | 153.2 |
| Three-phase 380V | |||||
| GD10-0R7G-4-B | 100.0 | 89.0 | 170.5 | 154.0 | 153.2 |
| GD10-1R5G-4-B | 100.0 | 89.0 | 170.5 | 154.0 | 153.2 |
| GD10-2R2G-4-B | 100.0 | 89.0 | 170.5 | 154.0 | 153.2 |
Note: When selecting a C3 input filter, the height (H1) of the inverter will increase. Please consider this during installation planning.
3. Installation
Safety Precautions:
- Risk of Electric Shock: Always ensure the power supply is disconnected before installing or performing any maintenance. Wait at least 5 minutes after powering off before proceeding, as residual voltage may be present.
- Hot Surfaces: The radiator and base of the VFD can become hot during operation. Do not touch these surfaces.
- Read the full manual before installation.

Image: Front view of the VFD highlighting safety warnings.
Mounting:
The INVT GD10 VFD is designed for wall mounting. Ensure the mounting surface is stable and can support the weight of the unit (approximately 2.5 kg).
Mounting Dimensions and Keypad Cutout:

Image: Diagram illustrating the cutout dimensions for external keypad installation.
Refer to the dimension table in Section 2 for specific model dimensions. Ensure adequate clearance for cooling.
Cooling Requirements:
- For single-phase 220V models with power ratings of 0.2-0.75kW, natural cooling is sufficient.
- For single/three-phase 220V models (1.5-2.2kW) and three-phase 380V models (0.75-2.2kW), fan cooling is employed. Ensure proper airflow around the unit and do not obstruct the cooling fins.
- Maintain an ambient temperature between -10°C and 50°C. If the temperature exceeds 40°C, the VFD's output capacity must be derated by 1% for every additional 1°C.
4. Operation
Control Panel:
The VFD features a standard LED keypad with a potentiometer for easy operation. Key buttons include:
- PRG/ESC: Program/Escape button.
- DATA/ENT: Data entry/Enter button.
- Up/Down Arrows: For navigation and value adjustment.
- SHIFT: For shifting digits during parameter entry.
- QUICK JOG: For quick jogging operations.
- RUN: To start the motor.
- STOP/RST: To stop the motor or reset faults.

Image: Front view of the VFD showing the control panel and buttons.
Basic Operation:
- Power On: Connect the VFD to the appropriate power supply (220VAC single-phase or 380VAC three-phase, depending on model).
- Frequency Setting: Adjust the output frequency using the built-in potentiometer or through digital settings via the keypad. The VFD supports digital, analog, multi-step speed, PID, and MODBUS communication settings.
- Start Motor: Press the RUN button to start the motor.
- Stop Motor: Press the STOP/RST button to stop the motor.
- Parameter Adjustment: Use the PRG/ESC and DATA/ENT buttons along with the arrow keys to navigate and modify parameters as needed for specific applications.
5. Maintenance
General Maintenance:
- Keep the VFD clean and free from dust and debris.
- Regularly check all electrical connections for tightness and signs of wear.
- Ensure cooling fins are not obstructed to maintain optimal heat dissipation.
Safety During Maintenance:
WARNING: Risk of Electric Shock!
- Always disconnect the main power supply to the VFD before performing any maintenance or inspection.
- Wait at least 5 minutes after disconnecting power to allow internal capacitors to discharge. Failure to do so may result in severe electric shock.
- Do not touch hot surfaces, especially the radiator and base, as they can remain hot for some time after operation.
6. Troubleshooting
The INVT GD10 VFD is equipped with more than 10 fault protections to ensure safe and reliable operation. In case of a fault, the VFD display will typically show an error code. Refer to the comprehensive manual for a complete list of error codes and their corresponding troubleshooting steps.
Common Issues and Solutions:
- No Power/Display Off: Check the main power supply and all input wiring connections.
- Motor Not Running: Verify the RUN command is active, check frequency settings, and ensure motor connections are correct.
- Overload Fault: Check motor load, ensure VFD capacity matches motor requirements, and inspect for mechanical issues in the driven equipment.
- Overtemperature Fault: Ensure proper cooling, clear any obstructions from cooling fins, and verify ambient temperature is within limits.
For persistent issues or complex fault codes, it is recommended to consult the detailed product manual or contact technical support.
7. User Tips
- Parameter Backup: Before making significant changes to parameters, record the current settings. This allows for easy restoration if unintended behavior occurs.
- Motor Tuning: For optimal performance, consider performing an auto-tuning function (if available in your specific model's firmware) to match the VFD's output characteristics to your motor.
- Environmental Control: While the VFD is robust, operating it within recommended temperature and humidity ranges will extend its lifespan and reliability.
- External Keypad: If the VFD is installed in a hard-to-reach location, consider using an external LED keypad for easier monitoring and control.
8. Warranty and Support
Certification:
This INVT GD10 VFD is CE certified, indicating compliance with health, safety, and environmental protection standards for products sold within the European Economic Area (EEA).
Manufacturer:
JX Automation Industry Co., Ltd
Technical Support:
For technical assistance, detailed wiring diagrams, or specific programming instructions not covered in this brief manual, please refer to the complete INVT GD10 series user manual provided with your product or contact JX Automation Industry Co., Ltd directly.