ZEEWEII DSO2512G

Contents

ZEEWEII DSO2512G Digital Oscilloscope User Manual

Model: DSO2512G

1. Introduction

The ZEEWEII DSO2512G is a versatile 2.8-inch handheld digital oscilloscope featuring a 120M bandwidth and dual-channel capabilities. It integrates a signal generator and supports XY mode, making it a powerful tool for various electronic measurement and debugging tasks. Utilizing ARM and FPGA chip collocation, it ensures high-speed signal acquisition and efficient data processing.

ZEEWEII DSO2512G Oscilloscope with Dual Channel, Signal Generator, 120M BW, Anti Burn, XY Mode

Figure 1: ZEEWEII DSO2512G Oscilloscope highlighting key features.

2. Key Features

  • Bandwidth: 120M (single channel), 60M (dual channel)
  • Display: 2.8-inch color screen with 320*240 pixel resolution
  • Signal Generator: Outputs various waveforms (sine, square, triangle, half, singh) with adjustable frequency (0-10MHz for sine, 0-2MHz for others) and fixed 2.5V amplitude.
  • Dual Channel: Simultaneous measurement on two channels.
  • XY Mode: Supports Lissajous curve display for phase comparison.
  • Video Output: Project screen to a TV or larger display via AV signal cable.
  • Trigger Modes: Auto, Normal, Single with Rise/Fall trigger types and Manual/Auto trigger level.
  • Measurements: 14 types including Frequency, Peak-to-Peak, Duty Cycle, Amplitude, RMS, Average, Period, Pulse Width, Max, Min, Top, Base.
  • Waveform Storage: Save and view up to 250 waveforms.
  • FFT Spectrum Analysis: Supports logarithmic, linear, and music spectrum display modes.
  • High-Performance Processor: ARM and FPGA chip combination for fast acquisition and processing.
  • Portability: Compact design with a 4000mAh built-in lithium battery.

3. Package Contents

Upon unpacking your ZEEWEII DSO2512G, please ensure all items listed below are present:

  • 1 x DSO2512G Digital Oscilloscope Unit
  • 2 x Probes
  • 1 x USB Cable (Type-C)
  • 1 x Video Cable
  • 1 x Gen Cable (Signal Generator Output Cable)
  • 1 x Storage Bag
  • 1 x User's Manual (physical copy)
ZEEWEII DSO2512G Oscilloscope package contents including probes, cables, storage bag, and user manual.

Figure 2: Contents included with the DSO2512G oscilloscope.

4. Specifications

ParameterValueParameterValue
ModelDSO2512GCouplingAC/DC
Channels2Measurement14 types
Screen size2.8 inchPrecision of V±2%
Resolution320*240 PixelsXY modeSupport
Bandwidth120M (CH1), 60M (CH1+CH2)Sampling rate500M
ScreenshotSupportRise time<3ns
Frequency accuracy±0.01%Storage depth128K
Single triggerSupportImpedance1MΩ
FFTSupportTime base5ns~10s
Wave out voltage2.5VVertical sensitivity10mV/div~10V/div
Wave out frequency10MHz (sin), 2MHz (other)Max voltage±40V (x1), ±400V (x10)
Trigger typerise/fallTrigger modeAuto/Normal
Display modeYT/RollPersistenceNone/1s/∞
LanguageCN/ENChargingType-C 5V
Battery4000mAh (included)Shell size82 * 137 * 38mm
Weight~286gBattery DemountableNo
DIY SuppliesElectricalOriginMainland China

Table 1: Detailed technical specifications of the DSO2512G.

5. Setup

5.1 Charging the Device

The DSO2512G is equipped with a built-in 4000mAh lithium battery. To charge the device, connect a Type-C 5V charger to the charging port. A charger is not included in the package, so please use a compatible Type-C 5V power adapter.

5.2 Connecting Probes

Connect the provided probes to the BNC connectors on the top of the oscilloscope. Ensure a secure connection. For general measurements, use the probes in their default configuration. For higher voltage measurements, ensure the probe's attenuation setting (e.g., x10) matches the oscilloscope's setting to prevent damage and ensure accurate readings.

ZEEWEII DSO2512G oscilloscope connected with two probes.

Figure 3: Oscilloscope with probes connected.

5.3 Connecting the Signal Generator Cable

To use the integrated signal generator, connect the 'Gen cable' to the output ports located at the bottom of the oscilloscope. The red hole is for the signal output, and the black hole is for GND (ground).

Oscilloscope showing signal generator output with red (signal) and black (GND) holes, and various waveform types.

Figure 4: Signal generator output ports and example waveforms.

6. Operation

6.1 Power On/Off

Press and hold the 'Save/Power' button to turn the oscilloscope on or off.

6.2 Basic Oscilloscope Functions

  • One-Click AUTO: Press the 'Auto' button for automatic waveform adjustment, which optimizes the display for the input signal.
  • Time Base & Vertical Sensitivity: Adjust these parameters using the dedicated buttons to scale the waveform horizontally and vertically.
  • Trigger Settings: The oscilloscope supports Auto, Normal, and Single trigger modes. You can select between Rise and Fall trigger types. The trigger level can be set manually or automatically.
Oscilloscope demonstrating trigger modes (Auto/Normal/Single) and trigger types (Rise/Fall).

Figure 5: Trigger settings interface.

  • Display Modes: Switch between YT (Voltage vs. Time) and Roll modes. Roll mode allows continuous scrolling of the waveform.
  • Persistence: Adjust persistence settings (None, 1s, ∞) to observe signal changes over time.
  • Measurements: The device offers 14 types of automatic measurements, including Frequency, Peak-to-Peak, Duty Cycle, Amplitude, RMS, Average, Period, +Pulse width, -Pulse width, Max, Min, Top, Base, and -Duty cycle.
  • FFT Analysis: Perform Fast Fourier Transform (FFT) to convert time-domain waveforms into the frequency domain. Supports logarithmic, linear, and music spectrum display modes.
Oscilloscope displaying various waveforms and FFT function.

Figure 6: FFT analysis display.

  • Waveform Save/View: Save up to 250 screen waveforms. Access the waveform preview page to view saved waveforms and delete unwanted ones.
Oscilloscope showing waveform save/view function with multiple thumbnails.

Figure 7: Waveform save and view interface.

6.3 Signal Generator Operation

The built-in signal generator can output sine waves (0-10MHz) and other waveforms (square, triangle, half, singh, 0-2MHz) with a fixed amplitude of 2.5V. Use the 'Gen' cable connected to the bottom ports (red for signal, black for GND) to output these waveforms. The frequency accuracy is up to 0.1Hz.

Oscilloscope displaying signal generator output with frequency and amplitude settings.

Figure 8: Signal generator output display.

6.4 XY Mode

The XY mode is used to display the relationship between two signals, typically for phase comparison. Connect one signal to Channel 1 and the other to Channel 2, then select XY mode from the menu.

Digital Oscilloscope highlighting Rich Features and showing an XY mode Lissajous curve.

Figure 9: XY mode displaying a Lissajous curve.

6.5 Video Output

Connect the provided video cable to the oscilloscope's video output port and to a compatible display (e.g., TV) to project the oscilloscope screen onto a larger monitor.

Oscilloscope demonstrating video output to an external screen via AV signal cable.

Figure 10: Video output connection to an external display.

6.6 Demonstration Video

Video 1: A demonstration of the DSO2512G oscilloscope features including time base, vertical sensitivity, 120M signal test, 220Vrms mains measurement, roll mode, single trigger, dual channel, XY mode, persistence, signal generator, FFT, and save/view functions.

7. Maintenance

7.1 General Care

Keep the oscilloscope clean by wiping it with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the screen or casing. Store the device in its provided storage bag when not in use to protect it from dust and physical damage.

7.2 Battery Care

The DSO2512G contains a non-demountable 4000mAh lithium battery. To prolong battery life, avoid fully discharging the battery frequently and store the device with a partial charge if it will not be used for an extended period. Recharge using a Type-C 5V power source.

8. Troubleshooting

  • Signal Generator Menu Persists: If the signal generator menu remains on screen and prevents other measurements, press the generator button again. The menu will disappear, but the generator will continue to function in the background.
  • No Charger Included: The package does not include a charger. Please use a standard Type-C 5V power adapter for charging.

9. User Tips

  • High Voltage Measurement: When measuring high voltages, such as 220V mains, always ensure your probe is set to x10 attenuation to prevent damage to the oscilloscope and ensure accurate readings.
  • External Synchronization: For external synchronization, one of the oscilloscope channels can be utilized as a trigger source.
  • Signal Generator Output Voltage: The built-in signal generator's output voltage is fixed at 2.5V. It is not adjustable. Only the waveform shape and frequency can be modified.

10. Warranty and Support

For any issues, malfunctions, or technical support inquiries, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific warranty terms and contact information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.