Hantek 6074BE/BC/BD/6254BD/BE

Contents

Hantek 6074 Series USB Digital Storage Oscilloscope User Manual

Models: 6074BE, 6074BC, 6074BD, 6254BD, 6254BE

Brand: Hantek

1. Introduction

The Hantek 6074 Series USB Digital Storage Oscilloscopes are versatile and portable instruments designed for a wide range of electronic measurements, with a particular focus on automotive diagnostics. These devices offer 4 channels, a bandwidth of up to 70MHz, and a real-time sampling rate of 1GSa/s, making them suitable for detailed waveform analysis. Their compact design and USB 2.0 interface ensure ease of use and portability, compatible with Windows 7, 8, and 10 operating systems.

Hantek 6074 Series Oscilloscope with various probes and cables
Figure 1: Hantek 6074 Series Oscilloscope and included accessories.

2. Key Features

  • Multi-Channel: 4 isolated channels for simultaneous signal analysis.
  • High Performance: Up to 70MHz bandwidth and 1GSa/s real-time sampling rate.
  • Memory Depth: 64K memory depth for capturing longer waveforms.
  • Automotive Diagnostics: Standard equipped with over 80 types of automotive measurement functions (e.g., Ignition Action, Sensor, Bus Diagnosis, Performer, Startup & Charge).
  • PC Compatibility: Supports Windows 7, Windows 8, and Windows 10 operating systems.
  • Plug & Play: USB 2.0 interface for easy connection without external power.
  • Advanced Measurement: Over 20 automatic measurement functions, PASS/FAIL check, resourceful trigger functions, dynamic cursor tracking, waveform record and replay.
  • Waveform Analysis: Supports waveform averaging, afterglow, lightness control, reverse, add, subtract, multiply, divide, X-Y display, and FFT spectrum analysis.
  • Data Export: Waveform data can be output to EXCEL, BMP, and JPG formats.
  • Expandability: Multiple oscilloscopes can be connected to one computer to easily expand the number of channels.
  • Development Support: Provides secondary development library DLL and development examples for Labview, VB, VC, and QT.

3. Models and Specifications

The Hantek 6074 Series offers several models with varying bandwidths and features. All models feature 4 channels, 1GSa/s real-time sampling, and 64K storage depth.

Hantek 6000 Series Selection Table showing models, channels, bandwidth, sampling rate, storage depth, signal generator, and car measurements
Figure 2: Hantek 6000 Series Selection Table. Note: Hantek products have no paper manual; all are electronic manuals.

3.1. Hantek 6074BE Specifications

Parameter Specification
ModelHantek6074BE
Bandwidth70MHz
Automotive Measurement FunctionIntake manifold vacuum & ignition; Petrol fumes adjusting valve vacuum & ignition; Idle exhaust ignition; Starting exhaust ignition; Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position; CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus; Performer: Petrol/Diesel; Starter and charging circuits
Channel4 CH
Real-time Sampling Rate1GSa/s
Memory Depth64K
Time Base Precision±50ppm
Time Base Range2ns/div-1000s/div (1-2-4 sequences)
Input Impedance1MΩ 25pF
Input Sensitivity2mV/div~10V/div
Vertical Resolution8Bit
Vertical Displacement Range2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe; 200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe
DC Gain Accuracy±3%
Bandwidth20MHz
Trigger ModeEdge, Pulse, Video, Alternative
Trigger SourceCH1, CH2, CH3,CH4
Waveform Signal Process+,-,x,÷,FFT, Invert
Cursors MeasurementCross, Trace, Horizontal, Vertical
Auto MeasurementVpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Volume175mm * 105mm * 25mm
Weight0.9KG

3.2. Hantek 6074BC Specifications

Parameter Specification
ModelHantek6074BC
Bandwidth70MHz
Channel4 CH
Real-time Sampling Rate1GSa/s
Memory Depth64K
Time Base Precision±50ppm
Time Base Range2ns/div-1000s/div (1-2-4 sequences)
Input Impedance1MΩ 25pF
Input Sensitivity2mV/div~10V/div
Vertical Resolution8Bit
Vertical Displacement Range2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe; 200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe
DC Gain Accuracy±3%
Bandwidth limit20MHz
Trigger ModeEdge, Pulse, Video, Alternative
Trigger SourceCH1, CH2, CH3,CH4
Waveform Signal Process+,-,x,÷,FFT, Invert
Cursors MeasurementCross, Trace, Horizontal, Vertical
Auto MeasurementVpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Volume175mm * 105mm * 25mm
Weight0.9KG

3.3. Hantek 6074BD Specifications

Parameter Specification
ModelHantek6074BD
Bandwidth70MHz
Channel4 CH
Real-time Sampling Rate1GSa/s
Memory Depth64K
Time Base Precision±50ppm
Time Base Range2ns/div-1000s/div (1-2-4 sequences)
Input Impedance1MΩ 25pF
Input Sensitivity2mV/div~10V/div
Vertical Resolution8Bit
Vertical Displacement Range2mV ~ 10V/div @ x1 probe; 20mV ~ 100V/div @ x10 probe; 200mV ~ 1000V/div @ x100 probe; 2V ~ 10000V/div @ x1000 probe
DC Gain Accuracy±3%
Bandwidth20MHz
Trigger ModeEdge, Pulse, Video, Alternative
Trigger SourceCH1, CH2, CH3,CH4
Waveform Signal Process+,-,x,÷,FFT, Invert
Cursors MeasurementCross, Trace, Horizontal, Vertical
Auto MeasurementVpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase, Vavg, Vrms, Vcrms, Preshoot, Overshoot, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle
Volume175mm * 105mm * 25mm
Weight0.9KG
Accessory2 passive probes, 2 gator clip lines

4. Package Contents

The standard package for the Hantek 6074BE model includes:

  • 1 x Hantek 6074BE USB Oscilloscope
  • 1 x HT307 Probe
  • 1 x HT19 Probe
  • 1 x HT18A Probe
  • 1 x HT30A Probe
  • 3 x Gator Clip Lines
  • 1 x HT25 Cable
  • 1 x USB Cable
  • 1 x CD (containing driver and manual)
  • 1 x User Manual (electronic)

For the Hantek 6074BC model, the package typically includes:

  • 1 x Hantek 6074BC USB Oscilloscope
  • 2 x Oscilloscope Probes (Note: Only 2 probes are included in the package. Additional probes may need to be purchased separately.)
  • 2 x BNC - Clip Cables
  • 1 x USB Cable
  • 1 x CD (containing driver and manual)
Hantek Oscilloscope and various accessories including probes, cables, and software CD
Figure 3: Typical package contents for Hantek 6074 Series.

5. Setup

  1. 5.1. Software Installation

    Insert the provided CD into your computer's CD-ROM drive. Follow the on-screen instructions to install the Hantek 6000 Series software. Ensure your operating system (Windows 7, 8, or 10) is supported. The software interface allows for language selection, including English, Dutch, German, French, Polish, Russian, and Spanish.

    Hantek 6000 software interface showing language selection menu
    Figure 4: Software language selection in Hantek 6000 Series application.
  2. 5.2. Hardware Connection

    Connect the Hantek oscilloscope to your computer using the supplied USB cable. The device is plug-and-play and does not require an external power supply.

    Side view of Hantek Oscilloscope showing USB and BNC input ports
    Figure 5: Side view of the Hantek Oscilloscope with USB and BNC ports.
  3. 5.3. Connecting Probes for Automotive Testing

    For automotive diagnostics, connect the appropriate probes (e.g., ignition probes, gator clip lines) to the BNC input channels (CH1, CH2, CH3, CH4) on the oscilloscope. Ensure secure connections. The device supports various automotive tests, including ignition, sensor, and bus diagnosis.

    Video 1: Demonstration of connecting probes for automotive ignition testing using the Hantek 6074BE.

6. Operating Instructions

  1. 6.1. Launching the Software

    After installing the software and connecting the oscilloscope, launch the Hantek 6000 Series application from your desktop or Start menu. The software will automatically detect the connected device.

  2. 6.2. Basic Waveform Display

    The main interface will display the waveforms from the connected channels. You can adjust vertical and horizontal scales, trigger settings, and other parameters using the controls within the software.

    Hantek 6000 software showing multiple waveforms on screen
    Figure 6: Multiple waveforms displayed on the Hantek 6000 software interface.
  3. 6.3. Automotive Diagnostic Functions

    Navigate to the 'Vehicle Diagnosis' menu within the software to access specialized automotive tests. This menu provides options for various diagnostic categories such as Ignition, Sensors, Bus Diagnosis, and more.

    Hantek 6000 software showing vehicle diagnosis menu with options like Ignition, Sensors, Bus Diagnosis
    Figure 7: Vehicle Diagnosis menu in the Hantek 6000 software.

    For example, to perform an ignition test, select 'Ignition' and then choose the specific type of ignition test (e.g., Primary, Secondary). The software will guide you through the connection and display the relevant waveforms.

    Hantek 6000 software displaying a secondary ignition waveform
    Figure 8: Example of a secondary ignition waveform display.
  4. 6.4. Measurement and Analysis

    The software offers various measurement tools:

    • Automatic Measurements: Access over 20 automatic measurements like Vpp, Vmax, Frequency, Period, etc., from the 'Measure' menu.
    • Cursors: Use horizontal and vertical cursors for precise manual measurements.
    • Waveform Processing: Perform mathematical operations (+,-,x,÷), FFT analysis, and invert waveforms.
    Hantek 6000 software showing the measurement menu with options for source, vertical, horizontal, and clear measure
    Figure 9: Measurement menu for detailed waveform analysis.

7. Maintenance

To ensure the longevity and optimal performance of your Hantek oscilloscope, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. Avoid using abrasive cleaners or solvents that could damage the casing or screen.
  • Storage: Store the oscilloscope in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity.
  • Cable Care: Handle USB and probe cables carefully. Avoid bending or crimping them excessively to prevent internal damage.
  • Software Updates: Regularly check the Hantek website for software updates to ensure you have the latest features and bug fixes.

8. Troubleshooting

If you encounter issues with your Hantek oscilloscope, consider the following common troubleshooting steps:

  • Device Not Recognized: Ensure the USB cable is securely connected to both the oscilloscope and the computer. Verify that the software drivers are correctly installed. Try connecting to a different USB port or computer.
  • No Waveform Display: Check that probes are properly connected to the input channels and the circuit under test. Verify trigger settings are appropriate for the signal being measured.
  • Software Issues: Restart the Hantek 6000 Series software and/or your computer. Reinstall the software if problems persist.
  • Incorrect Readings: Ensure probes are correctly calibrated and set to the appropriate attenuation (e.g., x1, x10). Check for proper grounding.

9. User Tips

  • Language Settings: The software supports multiple languages. If you need to change the display language, navigate to the software settings (refer to Figure 4 for an example of the language selection menu).
  • DC and AC Readings: The oscilloscope is capable of both DC and AC measurements. Ensure the correct coupling (DC or AC) is selected in the software for accurate readings.
  • Attenuator Use: For high voltage signals, an attenuator (if included or purchased separately) is crucial to protect the oscilloscope and ensure accurate measurements.
  • Software Updates: Hantek provides free software upgrades. Regularly check their official website for the latest versions to enhance functionality and performance.

10. Warranty and Support

Hantek provides continuous free software upgrading for their products, ensuring long-term value and improved functionality. For technical support, driver downloads, and the latest electronic manuals, please refer to the official Hantek website. The product is designed for durability with an anodized aluminum casing, offering good heat resistance and abrasive resistance.

© 2023 Hantek. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.