1. Introduction
The SMART SENSOR ST1393 EMF Meter is a handheld digital device designed to accurately detect and measure both electric field radiation and magnetic field emission simultaneously. It also features the capability to measure ambient environmental temperature in Celsius or Fahrenheit. This meter is equipped with an audible and visual dual alarm system that activates if tested values exceed preset safety thresholds, providing immediate alerts.
With a wide detecting frequency range for both magnetic (20Hz~300Hz) and electric (20Hz~3500MHz) fields, and precise measurement ranges (0.01~199.9μT for magnetic fields, 0~1999V/m for electric fields), the ST1393 offers high precision and sensitivity. Its user-friendly design includes soft operating buttons for mode selection, alarm value setting, MAX/AVG value switching, and unit conversion. Powered by three AAA batteries, its compact size ensures convenience for both use and portability. It is a reliable tool for measuring radiation from common electronic devices such as mobile phones, hair dryers, computers, TVs, printers, and refrigerators.
2. Safety Information
- Read this manual thoroughly before operating the device.
- Do not attempt to disassemble or modify the device. This may cause damage and void the warranty.
- Keep the device away from water and extreme temperatures.
- Ensure batteries are inserted correctly according to polarity markings. Remove batteries if the device will not be used for an extended period.
- This device is for measurement purposes only and should not be used as a substitute for professional safety assessments.
3. Product Overview
The ST1393 EMF Meter features a clear LCD display and intuitive controls for easy operation.
3.1 Components
- Sensor Position: Located at the top of the device, this is where the electromagnetic field sensors are housed.
- LCD Display: Digital screen showing magnetic field, electric field, and temperature readings, along with status indicators.
- Power Button (Red): Used to turn the device ON/OFF.
- MODE Button: Cycles through measurement modes (e.g., magnetic field, electric field, temperature).
- SET Button: Used for setting alarm values or confirming selections.
- UNIT Button: Toggles between measurement units (e.g., μT/mG, V/m, ℃/℉).
- Up/Down Buttons (▲/▼): Used for adjusting settings or navigating options.
- Battery Compartment: Located on the back, holds 3x AAA batteries.


4. Specifications
| Parameter | Value |
|---|---|
| Material | ABS |
| Magnetic Field Strength Range | 0.01~199.9μT (0.1~1999mG) |
| Electric Field Strength Range | 0~1999V/m |
| Magnetic Field Strength Resolution | 0.01μT/0.01mG |
| Electric Field Strength Resolution | 1V/m |
| Magnetic Field Strength Frequency Range | 20Hz~300Hz |
| Electric Field Strength Frequency Range | 20Hz~3500MHz |
| Temperature Measurement Range | -10~50℃ |
| Temperature Resolution | 0.1℃ |
| Power Supply | 3 * 1.5V AAA battery (NOT included) |
| Item Size | 130 * 50 * 27mm / 5.12 * 1.97 * 1.06in |
| Item Weight | 85g / 2.99oz |
| Package Weight | 127g / 4.48oz |
| Package Size | 19.3 * 7.5 * 3.5cm / 7.60 * 2.95 * 1.38in |
5. Setup
5.1 Battery Installation
- Locate the battery compartment cover on the back of the device.
- Slide or unclip the cover to open the compartment.
- Insert three (3) 1.5V AAA batteries, ensuring correct polarity (+ and -) as indicated inside the compartment.
- Replace the battery compartment cover, ensuring it is securely closed.

6. Operating Instructions
6.1 Power On/Off
- Press the red Power button to turn the device ON.
- Press and hold the red Power button for a few seconds to turn the device OFF.
6.2 Mode Selection
- After powering on, press the MODE button to cycle through the measurement modes: Magnetic Field, Electric Field, and Temperature. The active mode will be displayed on the LCD.
6.3 Unit Conversion
- In Magnetic Field mode, press the UNIT button to switch between microtesla (μT) and milligauss (mG).
- In Temperature mode, press the UNIT button to switch between Celsius (℃) and Fahrenheit (℉).
6.4 Alarm Setting
- To set the alarm threshold, press the SET button.
- Use the Up/Down buttons (▲/▼) to adjust the desired alarm value for magnetic or electric fields.
- Press SET again to confirm and exit the alarm setting mode.
- When the measured value exceeds the preset alarm, the device will emit an audible sound and a visual light signal.

6.5 MAX/AVG Value Switching
- While measuring, press the MODE button briefly to toggle between current, maximum (MAX), and average (AVG) readings.
6.6 Measurement Guidance
- For accurate readings, position the top part of the meter (Sensor Position) towards the object or area you wish to measure.
- Move the meter slowly around the area to detect variations in field strength.

7. Maintenance
- Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods to prevent leakage.
- Battery Replacement: Replace batteries when the low battery indicator appears on the display to ensure accurate readings.
8. Troubleshooting
8.1 Device Does Not Power On
- Check if the batteries are inserted correctly according to polarity.
- Replace with new AAA batteries.
- Ensure the power button is pressed firmly.
8.2 Inaccurate Readings
- Ensure the sensor position is correctly oriented towards the source of measurement.
- Avoid measuring in areas with strong interference from other electronic devices unless they are the target of measurement.
- Check battery level; low batteries can affect accuracy.
8.3 Alarm Not Functioning
- Verify that the alarm threshold is set correctly and is lower than the measured value you expect to trigger it.
- Ensure the device is not in a silent mode (if applicable, though not explicitly mentioned for this model).
9. User Tips
- Optimal Placement: For best results, hold the meter steadily and move it slowly around the area or device you are testing. Different angles and distances can yield varying readings.
- Baseline Readings: Take baseline readings in areas with known low EMF (e.g., outdoors, far from electronics) to understand typical background levels.
- Interpreting Alarms: The audible and visual alarms are designed to alert you to elevated levels. Familiarize yourself with the alarm thresholds and what they signify for your specific concerns.
- Battery Life: Always carry spare AAA batteries, especially for prolonged use, as the device relies on them for continuous operation.
10. Warranty and Support
KKMOON is committed to providing quality products. We strictly control quality problems before shipping to prevent outflow. If you encounter any product quality problems, you may return the item in its original condition for repair or exchange.
If the product is damaged during transit, please contact us immediately before opening any dispute or leaving negative feedback. We are dedicated to resolving any issues to your satisfaction.
10.1 Contact Information
For support or warranty claims, please contact your retailer or the KKMOON customer service channel through which you purchased the product.