1. Product Overview
The Meterk T80 Intelligent Pressure Controller is a sophisticated instrument designed for precise measurement and control of liquid levels. It utilizes a diffusion silicon chip encapsulated in a stainless steel housing, ensuring durability and accurate readings in various environments. The device features a clear 4-bit digital LED display and a light column display for intuitive monitoring.

Key Features:
- Advanced Sensor Technology: Employs a diffusion silicon chip with an oil-filled core in a stainless steel housing for reliable and accurate pressure detection.
- Protective Design: The front-end protective diaphragm allows smooth liquid contact while safeguarding the sensor.
- Condensation Prevention: Internal structure designed to prevent condensation, enhancing longevity and performance.
- Signal Processing: Built-in micro signal processing circuit for stable and reliable remote transmission.
- Clear Display: Features a 4-bit digital LED display and a light column display for easy data visualization.
- Wide Application: Suitable for water plants, sewage treatment, urban water supply, high-rise pools, wells, mines, industrial pools, water tanks, oil pools, hydrogeology, reservoirs, rivers, and oceans.
2. Specifications
| Parameter | Value |
|---|---|
| Model Number | T80 |
| Brand Name | Meterk |
| Origin | Mainland China |
| Detect Range | 0-200 meters |
| Accuracy | 0.5%FS |
| Resolution | 1/20000, 14 bits A/D converter |
| Display Type | LED display, Light Column Display |
| Output Signal | 4-20mA |
| Waterproof Rating | IP68 |
| Medium Temperature | -20℃ to 40°C |
| Item Dimensions (L x W x H) | 160mm x 95mm x 81mm (6.30in x 3.94in x 3.19in) |
| Package Dimensions (L x W x H) | 180mm x 120mm x 100mm (7.09in x 4.72in x 3.94in) |
| Package Weight | 0.6 kg (1.32 lb) |
| Certification | None |

3. Installation and Setup
Before installation, ensure all components are present and undamaged. The package includes one T80 Controller and typically a compatible liquid level sensor (may be sold separately).

3.1 Wiring Instructions
Refer to the wiring diagram below for proper electrical connections. Ensure power is disconnected before performing any wiring. The wire and housing are connected, and the vent pipe is connected to the outside in the cable to prevent condensation.

3.2 Sensor Placement
The liquid level sensor should be placed in the medium to be measured. The front-end protective diaphragm of the sensor is designed to allow smooth contact with the liquid while protecting the internal components.
4. Operating Instructions
The T80 controller features a user-friendly front panel with a light column display, a 4-bit digital LED display (PV), and control buttons for configuration and monitoring.

4.1 Front Panel Controls and Indicators
- Light Column Display: Shows the current measurement value visually, ranging from 0 to 100.
- PV (Process Value) Display: A 4-bit digital LED display showing the precise measurement value.
- Alarm Indicators:
- AHH: Upper-upper limit alarm.
- AH: Upper limit alarm.
- AL: Lower limit alarm.
- ALL: Lower-lower limit alarm.
- SET Button: Used to enter setup mode and confirm settings.
- Increase Button (Up Arrow): Used to increase values during setting or navigate menus.
- Reduce Button (Down Arrow): Used to decrease values during setting or navigate menus.
- Shift Button (Right Arrow): Used to shift cursor position or change digits during setting.
4.2 Basic Operation
- Power On: After proper wiring, apply power to the controller. The display will light up, showing the current liquid level or pressure value.
- Monitoring: Observe the light column display for a quick visual reference of the level and the PV digital display for the exact numerical value.
- Alarm Status: The AHH, AH, AL, ALL indicators will illuminate if the measured value exceeds or falls below the configured alarm thresholds.
4.3 Setting Parameters (e.g., Alarm Limits)
To configure parameters such as alarm limits:
- Press the SET button to enter the parameter setting mode.
- Use the Increase and Reduce buttons to navigate through different parameters.
- When the desired parameter (e.g., AH, AL) is displayed, press the SET button again to select it for editing.
- Use the Increase, Reduce, and Shift buttons to adjust the value.
- Press SET to confirm the new value and move to the next parameter or exit setting mode.
- Refer to the full product manual (if available) for detailed parameter descriptions and advanced settings.
5. Maintenance
Regular maintenance ensures the longevity and accuracy of your T80 Intelligent Pressure Controller.
- Cleaning: Periodically clean the exterior of the controller and the sensor with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Sensor Inspection: Inspect the liquid level sensor for any buildup, corrosion, or damage. Clean the sensor diaphragm if necessary, ensuring not to damage the protective layer.
- Connection Check: Verify that all electrical connections are secure and free from corrosion.
- Environmental Conditions: Ensure the controller is operated within the specified medium temperature range (-20℃ to 40°C) and protected from extreme conditions.
6. Troubleshooting
If you encounter issues with your T80 controller, consider the following basic troubleshooting steps:
- No Display/Power:
- Check power supply connections.
- Ensure the power source is active and providing the correct voltage (AC220V as per wiring diagram).
- Incorrect Readings:
- Verify the sensor is correctly installed and submerged in the medium.
- Inspect the sensor for any blockages or damage.
- Check wiring connections between the sensor and the controller.
- Ensure the controller's parameters are correctly calibrated for your application.
- Alarms Not Functioning:
- Check the alarm limit settings (AHH, AH, AL, ALL) to ensure they are configured appropriately.
- Verify that the output connections for alarms are correctly wired.
- Communication Issues (RS-485):
- Check RS-485 wiring for correct polarity and secure connections.
- Ensure communication parameters (baud rate, parity, etc.) are correctly set on both the controller and the connected device.
For persistent issues, contact customer support with details of the problem and any troubleshooting steps already taken.
7. Warranty and Support
The Meterk T80 Intelligent Pressure Controller comes with a 1-year guarantee from the date of purchase.
7.1 Warranty Claims
If your purchase does not meet merchantable quality, fitness for purpose, or match the description, please contact the seller within the warranty period. For defective or faulty products, provide photos or videos of the issue. The seller will arrange for a resend or refund after confirmation.
7.2 Customer Support
For any questions, technical assistance, or warranty claims, please contact the seller directly. Provide your product model (T80) and a detailed description of your inquiry to facilitate a quicker resolution.
8. User Tips
Based on common user inquiries and product characteristics:
- Brand Confirmation: This product is manufactured under the 'Meterk' brand.
- Condensation Prevention: The internal design helps prevent condensation, but ensuring the vent pipe is clear and properly connected is crucial for long-term reliability in humid environments.
- Clear Display: The combination of the light column and digital LED display provides both quick visual assessment and precise numerical data, making it easy to monitor liquid levels at a glance.