JUNCTEK KG110F

Contents

JUNCTEK KG110F High-Precision Coulomb Counter User Manual

Model: KG110F | Brand: JUNCTEK

1. Introduction

The JUNCTEK KG series voltage and current meter is a new type of coulomb meter designed for high-precision measurement and monitoring of various battery types. It can accurately measure and display physical parameters such as voltage, current, power, charge and discharge AH value, watt-hours, time, and temperature. This device also offers multiple programmable protection functions, including over-voltage, under-voltage, over-current, over-power, over-temperature, and time-limit protection. Its ability to automatically identify current direction and real-time battery capacity monitoring, coupled with a clear color LCD screen and mobile app control, makes it a versatile tool for battery management.

JUNCTEK KG110F Coulomb Counter with display, measuring module, shunt, and cables

Figure 1: KG110F Coulomb Counter and its components.

2. Package Contents

Please check the package contents upon receipt to ensure all items are present and undamaged:

Diagram showing all components included in the KG110F package, numbered 1 through 8.

Figure 2: Illustrated list of package components.

  • 1x Display Module
  • 1x Measuring Module
  • 1x Sampler (Shunt)
  • 1x Temperature Sensor
  • 1x 3P Terminal
  • 1x 3m Communication Cable
  • 1x 3P Connection Cable
  • 1x 4P Connection Cable

3. Key Features

  • High-Definition Color LCD: The display module features a 2.4-inch high-definition color LCD screen for clear and intuitive data presentation. Silicone buttons ensure smooth operation and fast response.
  • Bidirectional Current Detection: The product automatically recognizes and detects current flow in both charging and discharging directions. Charging current is displayed in green, while discharging current is displayed in blue.
  • Wide Battery Compatibility: Suitable for various battery types, including ternary lithium, lead-acid, and lithium iron phosphate batteries, provided they are within the specified voltage measurement range.
  • Pure Copper Shunt: The shunt and screws are constructed from pure copper, ensuring excellent electrical conductivity, low heat generation, and minimal power consumption, preserving battery life in standby mode.
  • Open Communication Protocol: Utilizes 485 communication with an open-source protocol, allowing for secondary development using tools like serial port assistants. Up to 99 meters can be controlled separately by switching communication addresses.
  • Mobile APP Control: Supports mobile application control via Bluetooth. The APP provides real-time data viewing, curve displays (real-time and historical voltage/current), and allows for full function configuration. Historical data can also be exported.
  • Comprehensive Protection Functions: Configurable protection settings for over-voltage (OVP), under-voltage (LVP), over-current (OCP/NCP), over-power (OPP), and external over-temperature (OTP). When a value exceeds the set protection range, the instrument's output state is turned off (requires a relay) to prevent damage to electrical equipment. Protection recovery time and delay time are adjustable.
  • Self-Calibration: Includes a self-calibration function to maintain accuracy of current and capacity values over extended periods of operation.
  • Data Management: Amp-hour, watt-hour, and time data can be cleared during measurement without affecting subsequent readings. Voltage and current values can be fine-tuned for precise capacity measurement.
Image showing various battery types and applications, indicating the meter's universal compatibility.

Figure 3: Universal compatibility with various battery types.

Shield graphic illustrating comprehensive protection features: OVP, OTP, LVP, OPP, OCP/NCP.

Figure 4: Comprehensive protection features.

Table listing protection types and their abbreviations: OVP, OTP, LVP, OPP, OCP, NCP.

Figure 5: Protection type definitions.

4. Technical Specifications

The following table details the technical parameters for the KG110F model, alongside other models in the series for comparison:

Table of technical specifications for KG105F, KG110F, KG140F, KG160F, and KG610F models, including sampling method, voltage/current measurement ranges, resolution, relay options, temperature range, capacity display, power range, accuracy, time range, Bluetooth distance, and various protection settings.

Figure 6: Technical Parameters Table.

Dimensions

Dimension diagrams for the display module, measuring module, and shunt, showing measurements in millimeters. Note: Embedded hole size for display module is 85.1 * 58.1mm.

Figure 7: Product Dimensions.

5. Installation and Wiring

The KG110F supports two main wiring configurations: self-powered and external power supply. Ensure all connections are secure and correctly polarized before powering on the device.

5.1. Self-Powered Wiring Diagram

In this configuration, the display module draws power directly from the battery being monitored. This is suitable for systems where the battery voltage is within the self-powered operating range of the device (typically 10-120V for KG110F).

Wiring diagram for self-powered mode, showing the battery connected to the shunt and the measuring module, which then connects to the display module. The load and charger are also connected to the shunt.

Figure 8: Self-Powered Wiring Diagram.

5.2. External Power Supply Wiring Diagram (with Relay Control)

For applications requiring a separate power source for the display module or when using the relay control function, an external power supply can be used. The external power supply voltage should match the working voltage of the relay (e.g., 12V or 24V).

Wiring diagram for external power supply with relay control. An external DC source powers the display module. The measuring module connects to the shunt, battery, and load. A relay is shown connected to the output control of the measuring module and the load circuit.

Figure 9: External Power Supply Wiring Diagram (Relay Control).

Important Note:

  • The external power supply voltage must be compatible with the relay's working voltage.
  • Ensure correct polarity for all connections to prevent damage to the device and connected equipment.
  • The shunt is crucial for current measurement; connect it correctly in series with the battery and load/charger.

6. Operation

6.1. Basic Display and Controls

The display module shows real-time voltage, current, power, AH value, watt-hours, time, and temperature. Use the physical buttons (SET, UP, DOWN, OK) on the display module to navigate menus and adjust settings.

Close-up view of the KG110F display module showing its screen and control buttons (SET, Up, Down, OK).

Figure 10: Display Module Interface.

6.2. Mobile APP Control

For advanced monitoring and control, download and install the official JUNCTEK APP on your smartphone. Connect to the device via Bluetooth.

Video 1: Demonstration of discharge and charging current detection, and various application scenarios.

Screenshots of the mobile app interface showing settings, main display with battery status, and curve display for voltage and current over time.

Figure 11: Mobile App Interface for control and monitoring.

The APP allows you to:

  • View all measured data in real-time.
  • Access real-time and historical voltage/current curves.
  • Configure all device settings, including protection parameters.
  • Export historical data for analysis.

6.3. Setting Battery Capacity

To ensure accurate capacity readings, set the actual capacity value of your battery in the device settings. This can be done via the display module or the mobile APP.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the display and housing. Do not use abrasive cleaners or solvents.
  • Connection Check: Periodically inspect all wiring connections for tightness and corrosion.
  • Self-Calibration: The device features a self-calibration function to maintain accuracy. Refer to the device settings or APP for initiating calibration if needed.
  • Firmware Updates: Check the manufacturer's website or APP for available firmware updates to ensure optimal performance and access to new features.

8. Troubleshooting

  • No Display/Power: Check power connections and ensure the battery voltage is within the operating range. If using external power, verify the power supply is functional.
  • Inaccurate Readings: Ensure the shunt is correctly installed and all connections are secure. Perform a self-calibration if readings seem consistently off. Verify the set battery capacity matches the actual battery.
  • Bluetooth Connection Issues: Ensure Bluetooth is enabled on your smartphone and the device. Restart both the device and the APP. Check for any obstructions that might interfere with the signal.
  • Protection Triggered: If a protection function (OVP, LVP, OCP, OPP, OTP) is triggered, identify the cause (e.g., over-voltage, excessive current) and rectify it. The device will typically indicate the triggered protection.
  • Relay Not Activating: Verify the relay is correctly wired and its working voltage matches the external power supply. Check the protection settings in the device or APP to ensure they are configured as desired.

9. User Tips

  • Initial Battery Value: If the battery value doesn't show 100% after installation, ensure you have correctly set the total capacity of your battery in the device settings or through the mobile app. A full charge cycle after setting the capacity can help the device learn the battery's state more accurately.
  • Historical Data Retention: The device's internal memory for historical curves is limited. For long-term data analysis, regularly export historical data via the mobile app to your phone or other storage.
  • Optimal Shunt Placement: For the most accurate current measurements, ensure the shunt is installed as close as possible to the battery's negative terminal, and all high-current connections are robust.

10. Certifications

The JUNCTEK KG110F Coulomb Counter is certified with:

  • CE
  • FCC
  • pse