1. Introduction
Thank you for choosing the VEVOR Sauna Spa Steam Generator. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your steam generator. Please read this manual thoroughly before installation and use, and keep it for future reference.
Product Overview
The VEVOR Steam Generator is designed to provide a relaxing and therapeutic steam experience in your home sauna or steam shower. Featuring quick heating, a digital controller for precise temperature and time management, and durable 304 stainless steel construction, this unit ensures a reliable and enjoyable experience. It is equipped with multiple safety protections, including overheating protection and a manual drain system.
2. Safety Information
- Read all instructions before using this appliance.
- This appliance must be grounded. Connect only to a properly grounded outlet.
- Do not operate the steam generator if the power cord or plug is damaged, or if the unit has been dropped or damaged in any way.
- Ensure proper ventilation in the steam room to prevent excessive heat buildup.
- Do not allow children to operate the steam generator without supervision.
- Always ensure the water tank is filled before operation to prevent dry burning.
- Warning: Hold fittings securely with a pipe wrench while making plumbing connections to the water inlet to prevent internal damage to the water solenoid valve.
- This unit is not to be used for space heating purposes.
3. Product Components
The VEVOR Steam Generator system typically includes the following components:
- Steam Generator Unit
- Digital Controller (TC-135 for 4/6/7KW, KS-100 for 9KW)
- Probe Coil
- Control Line
- Steam Nozzle
- Set of Steam Outlet Fixed Accessories

Figure 1: Steam Generator with labeled connections (Water Inlet, Steam Outlet, Draining Pipe)

Figure 2: Digital Controllers (TC-135 and KS-100)
4. Specifications
| Feature | 4KW Model | 6KW Model | 7KW Model | 9KW Model |
|---|---|---|---|---|
| Model Number | ST-60 Series | |||
| Voltage | 220V/240V | |||
| Power | 4 kW | 6 kW | 7 kW | 9 kW |
| Temperature Range | 95 °F - 131 °F / 35-55℃ | |||
| Water Tank Capacity | Not specified | 1.1 Gallon / 4.3L | 1.6 Gallon / 6L | 1.6 Gallon / 6L |
| Recommended Room Volume | Not specified | 212 ft³ / 6 m³ | 247 ft³ / 7 m³ | 318 ft³ / 9 m³ |
| Heater Size (L x W x H) | Not specified | 15.6" x 6" x 12.3" / 39.5 x 15.3 x 31.3 cm | 17.5" x 7.2" x 12.3" / 44.5 x 18.2 x 31.3 cm | 17.5" x 7.2" x 12.3" / 44.5 x 18.2 x 31.3 cm |
| Weight | 22 lbs / 10 kg | |||
| Material | 304 Stainless Steel | |||
| Certification | CE, ISO9001:2000 SGS Certification Report | |||
Note: Specific dimensions and water tank capacity for the 4KW model were not provided in the source data.
5. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your steam generator. It is recommended that installation be performed by a qualified electrician and plumber.
5.1 Mounting the Steam Generator
- Choose a dry, well-ventilated location for mounting the steam generator, preferably near the steam room but outside of it.
- Ensure the unit is mounted securely to a wall using appropriate fasteners. The unit has pre-drilled mounting holes.
- Allow sufficient space around the unit for ventilation and maintenance access.
5.2 Plumbing Connections

Figure 3: Operational Safety Warning for Water Inlet Connection
- Water Inlet: Connect a cold water supply line to the water inlet port on the steam generator. Use a pipe wrench to securely hold the fitting while making the connection to prevent damage to the internal solenoid valve.
- Steam Outlet: Connect a steam-rated pipe from the steam outlet port to the steam nozzle inside the steam room. Ensure the pipe slopes slightly towards the steam room to prevent condensation buildup.
- Draining Pipe: Connect a draining pipe to the manual drain valve. This pipe should lead to a suitable drain.
- Ensure all plumbing connections are watertight and sealed properly.
5.3 Electrical Connections
- The steam generator requires a 220V/240V electrical supply. Consult a qualified electrician to ensure proper wiring and circuit breaker sizing for your specific model (4KW, 6KW, 7KW, or 9KW).
- Connect the power supply to the designated electrical terminal block on the steam generator.
- Ensure the unit is properly grounded according to local electrical codes.
- Connect the control line from the digital controller to the steam generator unit.
5.4 Temperature Sensor Installation
The temperature sensor (probe coil) should be installed inside the steam room, typically on a wall about 6-12 inches (15-30 cm) below the ceiling, away from the direct path of the steam outlet. Ensure it is not exposed to direct water spray or drafts, which could affect temperature readings.
6. Operating Instructions
Once installed, operating your VEVOR Steam Generator is straightforward using the digital controller.
6.1 Initial Start-up
- Ensure all plumbing and electrical connections are secure and the water supply is turned on.
- Turn on the main power switch for the steam generator.
- The unit will begin to fill with water. Once filled, it will start heating.
6.2 Using the Digital Controller

Figure 4: Temperature & Time Monitor
- Power On/Off: Use the 'ON/OFF' button or switch on the controller to activate or deactivate the unit.
- Set Temperature: Press the 'SET TEMP' button (or equivalent on KS-100) and use the Up/Down arrows to adjust the desired temperature between 95 °F - 131 °F (35-55℃).
- Set Time: Use the time setting buttons (or equivalent) to set the desired operating duration for your steam session.
- Start/Stop: Press 'START/STOP' to begin or end a steam session.
- The controller will display the current temperature and remaining time.
6.3 Steam Generation
The generator will typically produce steam within 3-5 minutes of starting, depending on the model and initial water temperature. The unit will maintain the set temperature throughout your session.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your steam generator.
7.1 Draining the Water Tank

Figure 5: Manual Drain Valve Location
- After each use, or at least weekly, open the manual drain valve to empty the water tank. This helps prevent mineral buildup and keeps the steam clean.
- Allow the unit to cool down before draining.
7.2 Descaling
- Depending on water hardness, periodic descaling may be necessary (e.g., every 3-6 months).
- Consult a professional or refer to specific descaling instructions provided with your unit if available.
7.3 Cleaning the Steam Nozzle
- Periodically check the steam nozzle for any blockages or mineral deposits.
- Clean the nozzle as needed to ensure an unobstructed steam flow.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No steam production | No power; Water supply off; Low water level; Overheat protection activated; Heating element failure. | Check power connection and circuit breaker; Ensure water supply is open; Check water level and refill; Allow unit to cool down; Contact support for heating element replacement. |
| Insufficient steam | Mineral buildup; Steam nozzle clogged; Room volume too large for generator power. | Descale the unit; Clean the steam nozzle; Ensure generator power matches room volume (refer to specifications). |
| Water leakage | Loose plumbing connections; Damaged seals. | Tighten all plumbing connections; Inspect and replace damaged seals. |
| Controller not responding | Loose control line connection; Controller malfunction. | Check control line connection; Contact support for controller replacement. |
| Temperature sensor inaccurate | Sensor improperly placed; Faulty sensor. | Relocate sensor away from direct steam/water; Contact support for sensor replacement. |
9. User Tips
- Power Cable Sizing: For optimal performance and safety, ensure the electricity cable used for installation is appropriately sized for your generator's power (e.g., a 6KW generator requires a specific gauge cable as per electrical codes). Consult an electrician.
- Temperature Sensor Placement: To get accurate temperature readings, install the temperature sensor away from the direct steam flow and any water spray. A common placement is high on the wall, opposite the steam outlet.
- Room Volume Matching: When selecting a steam generator, match its power (KW) to your steam room's volume (m³ or ft³). For example, for a small space of 2x1.5 meters (approx. 3 m³), a 4KW or 6KW unit might be suitable, while a 9KW unit is recommended for rooms up to 9 m³ (318 ft³).
- Online Resources: If you encounter installation or operation issues, check for online video tutorials or additional resources provided by VEVOR.
10. Warranty and Support
VEVOR products are built to last and come with a commitment to quality. For specific warranty details and to access customer support, please refer to the official VEVOR website or contact their customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.