Jesudom GTN-1200W/GTN-1000W

WIFI Version 1000W 1200W Solar Grid Tie Inverter Instruction Manual

Model: GTN-1200W/GTN-1000W | Brand: Jesudom

1. Introduction

This advanced solar grid tie inverter is designed to efficiently convert DC power from solar panels or battery banks into AC power for your home or grid. Featuring a built-in limiter function, it prevents excess power export to the grid, ensuring optimal self-consumption. The WIFI version allows for convenient monitoring via a mobile application.

2. Safety Information

Important Safety Warning:

If the inverter is damaged due to human connection errors or lightning strikes, no free warranty service will be provided. Please carefully read this manual and all product information before installation and operation. If you have any questions, please contact customer support first.

Warning: No free warranty for human error or lightning damage

Image: Warning regarding warranty exclusions for human error or lightning strikes.

3. Product Overview

The Jesudom Solar Grid Tie Inverter is a robust device designed for solar power systems. Key features include:

  • WIFI monitoring capability (via mobile app for Android devices).
  • Integrated Limiter function for zero export to the grid.
  • Supports DC 24V and 48V battery banks.
  • Outputs AC 110V or 220V at 50Hz or 60Hz.

The package typically includes the inverter unit, a WIFI module, an AC Power Meter, and a CT Sensor for limiter functionality.

Jesudom Grid Tie Power Inverter with accessories

Image: Overview of the Jesudom Grid Tie Power Inverter and its accompanying components.

Jesudom Grid Tie Power Inverter with Limiter and WIFI module

Image: Close-up view of the inverter with the limiter and WIFI module.

4. Specifications

Refer to the table below for detailed technical specifications of the GTN-1000W and GTN-1200W models:

ParameterGTN-1000W (With limiter)GTN-1200W (With limiter)
Rated AC output power(W)1000W1200W
PV Max input power(W)1100W1300W
Recommended PV power range(W)200W-1100W200W-1300W
PV Input voltage range Voc(V)26V-45V, 39V-62V, 55V-90V, 85V-130V, 120V-180V26V-45V, 39V-62V, 55V-90V, 85V-130V, 120V-180V
DC Input branch number11
MPPT Tracking range(V)21-31V, 32-45V, 44-70V, 65-100V, 90-135V21-31V, 32-45V, 44-70V, 65-100V, 90-135V
Battery Voltage24V, 36V, 48V/60V, 72V, 96V24V, 36V, 48V/60V, 72V, 96V
Battery Start voltage range21-30V, 35-45V, 47-71V, 70-100V, 94-120V21-30V, 35-45V, 47-71V, 70-100V, 94-120V
Battery Low voltage shutdown range21-30V, 33-44V, 43-70V, 66-99V, 88-119V21-30V, 33-44V, 43-70V, 66-99V, 88-119V
Max input protection current40A, 30A, 25A, 15A, 15A40A, 30A, 25A, 15A, 15A
AC Output Parameters
Max inverter efficiency88%89%
AC output range220VAC(190-260VAC) or 120VAC(90-135VAC)220VAC(190-260VAC) or 120VAC(90-135VAC)
Frequency range50Hz(48-52) or 60Hz(58-62)50Hz(48-52) or 60Hz(58-62)
Other Electrical Parameters
MPPT Tracking Efficiency>99%>99%
Power Factor>98%>98%
Stand-by Power<2W<2W
Island effect protectionVAC, FACVAC, FAC
Protection FunctionDC overvoltage / overcurrent; AC overvoltage / overcurrent / overfrequency; over temperature protectionDC overvoltage / overcurrent; AC overvoltage / overcurrent / overfrequency; over temperature protection
Work Status IndicationColor LCD Display(Chinese/English Display Can be Self-adjusted) or WIFI monitor via APPColor LCD Display(Chinese/English Display Can be Self-adjusted) or WIFI monitor via APP
Work Temperature-20°C - 65°C-20°C - 65°C
Communication methodRS485+limiter sensor=grid tie inverter with limiterRS485+limiter sensor=grid tie inverter with limiter
Size(L*W*H)MM305*190*110mm305*190*110mm
Package Size(MM)420*260*170mm420*260*170mm

Image: Detailed specifications table for GTN-1000W and GTN-1200W models.

5. Setup and Installation

5.1. System Connection Diagram

The inverter can be directly connected to solar panels or battery banks. Below are common connection methods:

Diagram showing various connection methods for the inverter with solar panels, battery, grid, and load.

Image: Comprehensive system connection diagram for the inverter, including solar panels, battery pack, MPPT controller, grid meter, breaker, and load. Four matching methods are available: 1.A+C+D, 2.C+D+B, 3.A+B+C+D+E, 4.C+D+(A+E+B)x10.

5.2. Limiter Connection

The limiter function helps prevent excess power export to the grid. Follow these steps to connect the limiter:

  1. Connect the RS485 cable of the AC power acquisition meter to the 485 port of the inverter.
  2. Plug the connection terminal of the transmitted current sensor into the port of the collector "CT-IN" (no +/-).
  3. Connect the AC power supply port "AC-IN" of the collector to the same AC power supply for the load. After the connection, it will light up.
  4. In the inverter LCD, enter the "battery grid connection" menu, through the SET (Bat AutoLimit Grid).
  5. Connect the inverter to AC power first, then connect the battery. The inverter will automatically output the same power as the power detected by the collector. Therefore, the inverter will not have excess electricity to be sent to the grid (i.e., automatic limiter function).
  6. One acquisition meter can connect 5 unit grid tie inverters.
Diagram illustrating how to connect the Limiter to the inverter system.

Image: Diagram detailing the connection of the Limiter, including the AC Power Meter, CT Sensor, Breaker, and Load.

6. Operating Instructions

6.1. WIFI Module User Manual (for Android phones only)

The WIFI module allows you to connect your mobile phone to the inverter for monitoring. There are two ways to connect:

6.1.1. NET Mode (Wireless Router Connection)

In NET Mode, the blue LED on the WIFI module is connected to the wireless network. You can use the mobile phone at any place, time, to view or control the status of the inverter.

  1. Click the list icon in the upper right corner of the login interface.
  2. Select Device Configure and then select Configure.
  3. Click OK. Follow the prompts to enter the SSID name and password for the wireless router to which your phone is currently connected.
  4. Plug the WIFI module into the TTL-WIFI port of the inverter, and the inverter is connected to the AC power supply.
  5. Press and hold the SET key on the WIFI module for 4 seconds. Release it. The NET blue LED flashes, and then click the Start Configure button on the configure interface of the APP. If opened, after the prompt is successful, click OK, and then press the SET key on the WIFI module again. The WIFI module will restart.
  6. Log in to the mobile APP and enter the interface of device list, then click the icon in the upper right corner and click Add Device to input S/N code to add device. The newly added WIFI device will then appear in the device list.

6.1.2. AP Mode (Mobile Phone Direct Connection)

In AP Mode, the red LED on the mobile phone wireless WIFI point-to-point direct connection WIFI module is active. The red and blue LED will flash at the same time. Just press the SET key on the WIFI module 3 times. The red and blue LED will flash at the same time. Just press the SET key again, the blue LED single flash is in NET mode. Press SET again, the red LED single flash is AP mode. After selecting the mode and waiting for flashing for 5 seconds, the selected mode will take effect. The mode LED is always on.

  1. Follow the steps above to switch between NET mode and AP mode. Select AP mode (Red LED is always on).
  2. Open the wireless WIFI of mobile phone, find the WIFI named Soyo_XXXXXX and click Connect, enter the password 88888888 (eight 8's) to connect.
  3. After the connection, open the APP software on the mobile phone. In the login interface, click the list icon in the upper right corner. Click AP Mode, click connection. You can directly enter the data display interface to view and set parameters.

Note: The WIFI app can only be used on Android phones and cannot be used on Apple phones.

WIFI Module User Manual for Android phones

Image: Detailed instructions for connecting the WIFI module to a mobile phone via NET mode and AP mode.

Video: Demonstration of connecting the WIFI module to a mobile phone.

6.2. Inverter Working Mode Setting

The inverter supports various working modes. You can configure these settings via the inverter's display panel or the mobile app.

6.2.1. Normal PV Mode

Press the Set button on the inverter display panel, enter the [Battery Grid Tie Set] item, set [Battery CP Grid] to N, and [Bat AuotLimit Grid] to N. Press the Set key to save, then press Esc key to exit and return.

6.2.2. PV Limiter Mode

In the normal PV mode, connect the RS485 line of the power meter and power on, and the inverter will automatically switch to the PV Limit function. (If you need to restore the normal PV mode, just unplug the 485 line, and then Restart the inverter)

6.2.3. Battery CP Mode

Enter the [Battery Grid Tie Set] item, set [Battery CP Grid] to Y, press the Set key to save, and then press the Esc key to exit and return.

6.2.4. Battery Limiter Mode

Enter the [Battery Grid Tie Set] item, set [Battery CP Grid] to N, [Bat AuotLimit Grid] to Y, press the Set key to save, and then press the Esc key to exit and return.

Inverter Working Mode Settings on display panel

Image: Screenshot showing the inverter display panel with options for Battery Grid Tie Set and AutoLimit Grid.

Mobile app interface for inverter mode settings

Image: Mobile app interface displaying various working modes like PV Mode, PV Limit Mode, Battery Constant Power Mode, and Battery Limit Mode, along with settings for delay start time, battery output power, and battery start/shutdown voltages.

7. Maintenance

To ensure optimal performance and longevity of your Jesudom Solar Grid Tie Inverter, regular maintenance is recommended:

  • Cleaning: Keep the inverter's exterior clean and free from dust and debris. Use a soft, dry cloth. Do not use liquid cleaners.
  • Ventilation: Ensure that the inverter's ventilation openings are not blocked to prevent overheating.
  • Connections: Periodically check all electrical connections (DC input, AC output, RS485, WIFI module) to ensure they are secure and free from corrosion.
  • Environmental Conditions: Ensure the inverter is operating within its specified temperature range (-20°C to 65°C) and is protected from direct sunlight, rain, and excessive humidity.
  • Firmware Updates: Check the manufacturer's website or app for any available firmware updates to improve performance and add new features.

8. Troubleshooting

This section addresses common issues you might encounter with your inverter. For more complex problems, please contact customer support.

8.1. Common Questions & Answers

Q1: What's the type of the inverter?
A1: This series of inverters are grid-tie, they will feed power to the local grid. If you don't want to feed power to the grid, please choose the limiter version.
Q2: What's the advantage of 500W and 600W, 1KW and 1.2KW grid tie inverter?
A2: They can both work with solar panels and batteries. 500W and 600W grid tie inverters can adjust the AC output power. 1KW and 1.2KW can work with a limiter which can be a zero export function.
Q3: What's the difference between LCD version and WIFI version for 1000W 1200W Model?
A3: The LCD version just monitors the generating data on the LCD display. The WIFI version just monitors the data on the APP.
FAQ about inverter types, advantages, and LCD vs WIFI versions.

Image: Frequently Asked Questions regarding inverter types, advantages, and differences between LCD and WIFI models.

8.2. WIFI Connection Issues

  • If the blue LED on the WIFI module is not on in NET Mode, ensure it's properly connected to a wireless network.
  • If the red LED is not on in AP Mode, ensure the mobile phone is directly connected to the inverter's WIFI hotspot.
  • Ensure you have selected the correct 4G network and entered the correct password during setup.
  • The WIFI app is only compatible with Android phones. Apple phones are not supported for direct app monitoring.

9. User Tips

  • WIFI Connectivity: For optimal monitoring, ensure your Android phone is connected to a stable 4G network when using the inverter's WIFI features. Remember to input the correct 4G network password during setup.
  • Limiter Function: Utilize the limiter function to prevent feeding excess power back to the grid, especially if local regulations require zero export. Ensure the CT sensor is correctly installed and configured.
  • Battery Compatibility: This inverter is designed to work with battery banks. Properly configure battery voltage settings (start and shutdown voltages) to protect your batteries and ensure efficient operation.

10. Warranty and Support

This product comes with a 1-year warranty. Please retain your proof of purchase for any warranty claims.

For technical support, troubleshooting assistance, or warranty inquiries, please contact Jesudom Official Store customer service. Ensure you have your product model number and purchase details ready.

Note: Warranty service may be voided if the product is damaged due to improper installation, human error, or natural disasters like lightning strikes. Always follow the instructions provided in this manual.

Jesudom logo and PL warehouse information

Image: Jesudom branding and mention of PL warehouse for after-sales service.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.