1. Introduction
The COMPTYCO AUA-330A/AUA-330U is a high-performance handheld fiber optical PON power meter designed for efficient and accurate testing in FTTX (Fiber to the X), ONT (Optical Network Terminal), and OLT (Optical Line Terminal) networks. This device is capable of simultaneously testing three wavelengths: 1310nm, 1490nm, and 1550nm, making it an essential tool for fiber optic network installation, maintenance, and troubleshooting. Its robust design and user-friendly interface ensure reliable performance in various field conditions.
2. Product Overview
2.1 Key Features
- Three Wavelengths Wide Range: Tests 1310nm, 1490nm, and 1550nm simultaneously with an accuracy control error within ±0.5dB.
- Two-Port Straight-Through Design: Guarantees entire communication from OLT to ONT during testing. Features a 1310nm detection interface for ONT uplink signals and 1490/1550nm detection interface for OLT downlink signals.
- LED Lamp: Integrated LED lamp for working in low-light conditions.
- SC/FC Interface: Supports interchangeable SC/FC connector types for versatile use on site.
- Data Storage: Capable of storing up to 10 sets of measurement data.
- Self-Calibration Mode: Allows for user calibration to maintain accuracy.
- Soft Silicone Design: Protective silicone sleeve reduces damage from collisions and falls.
- Power Source: Operates on a 9V dry battery.



2.2 Package Contents
The product package typically includes the following items:
- Host (PON Power Meter)
- FC adapter *2 (installed on the host)
- SC adapter *2
- Ceramic core *2
- Instruction Manual
- Fall-proof bag
- Packing box

2.3 Function Keys

- Power Button (①): Used to switch the device ON/OFF. Also controls the Auto Power Off feature.
- A/UNIT Button: Switches display units and can be used for Burst mode settings.
- THR Button: Activates threshold design and allows for threshold setting.
- REF/LED Button: Used for reference settings, as a reference power key, and to activate the LED lamp.
- V/LOAD Button: Facilitates user calibration settings and allows saving or viewing saved results.
- SEL Button: Primarily used for data storage functions.
- Display Screen: Shows measurement readings, selected wavelengths (1310nm ONT, 1490nm OLT, 1550nm VIDEO), battery status, and other operational information.
3. Specifications

| Parameter | 1310nm | 1490nm | 1550nm |
|---|---|---|---|
| Test Wavelength | 1310 ± 50nm | 1490 ± 15nm | 1550 ± 10nm |
| Isolation (1310nm) | -- | >40dB | >40dB |
| Isolation (1490nm) | >40dB | -- | >40dB |
| Isolation (1550nm) | >40dB | >40dB | -- |
| Measuring Range | -35 ~ +10dBm | -40 ~ +12dBm | -40 ~ +25dBm |
| Measurement Uncertainty | ≤0.5dB | ||
| Insertion Loss | ≤0.5dB | ||
| Probe Type | InGaAs | ||
| Display Resolution | 0.1dB | ||
| Fiber Type | SM 9/125μm | ||
| Threshold Setting | Group 10 | ||
| Optical Connector | FC/APC (Interchangeable SC/ST) | ||
| Parameter | Value |
|---|---|
| Display | Color LCD screen |
| Data Storage | 10 sets |
| Power Supply Mode | 9V dry battery |
| Operating Temperature | -10℃ ~ +50℃ |
| Storage Temperature | -40℃ ~ +70℃ |
| Relative Humidity | 0-90% dew-free |
| Volume | 180mm × 89mm × 42mm |
| Machine Weight | ≤254g |
4. Setup
4.1 Battery Installation
- Locate the battery compartment on the back of the device.
- Open the battery compartment cover.
- Insert one 9V dry battery, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.

4.2 Adapter Installation
The device comes with FC adapters pre-installed and includes additional SC adapters. To change adapters:
- Gently unscrew the currently installed adapter from the PON Power Meter's input port.
- Select the desired adapter (FC or SC).
- Carefully screw the new adapter onto the input port until it is snug. Do not overtighten.
- Ensure the ceramic core is properly seated within the adapter.
5. Operating Instructions
5.1 Power On/Off
Press and hold the Power Button (①) for a few seconds to turn the device ON or OFF.
5.2 Performing a PON Test
- Ensure the correct fiber optic adapter (FC or SC) is installed for your connection type.
- Connect the fiber optic cable from the network to the appropriate input port on the PON Power Meter. For OLT downlink signals (1490/1550nm), use the designated port. For ONT uplink signals (1310nm), use the other port.
- Power on the device. The display screen will show the current readings for 1310nm, 1490nm, and 1550nm wavelengths.
- The device will automatically detect and display the power levels (Lo dBm) for each wavelength.
- To switch display units, press the A/UNIT Button.
5.3 Using the LED Lamp
Press the REF/LED Button briefly to turn the integrated LED lamp ON or OFF, providing illumination for working in dark environments.
5.4 Data Storage and Retrieval
The device can store up to 10 sets of measurement data.
- After a measurement, press the SEL Button to save the current readings.
- To view saved results, press the V/LOAD Button. Use the arrow buttons (if available, or repeated presses of V/LOAD/SEL) to navigate through stored data.
5.5 Threshold Setting
The device supports threshold settings (Group 10 by default) to quickly identify acceptable signal levels.
- Press the THR Button to enter threshold setting mode.
- Follow the on-screen prompts or use the navigation buttons to adjust the threshold values as needed.
- Press THR again to confirm and exit the setting mode.
5.6 Self-Calibration
To ensure measurement accuracy, the device features a self-calibration mode.
- Refer to the detailed instructions in the included instruction manual for the specific steps to perform self-calibration using the V/LOAD Button.
- It is recommended to perform self-calibration periodically or if you suspect measurement inaccuracies.
6. Maintenance
6.1 Cleaning Optical Connectors
Regularly clean the optical connectors and adapters to ensure accurate measurements. Use only approved fiber optic cleaning tools and methods. Dust and debris can significantly impact measurement accuracy.
6.2 Battery Replacement
When the battery indicator on the display shows low power, replace the 9V dry battery as described in Section 4.1. Remove the battery if the device will not be used for an extended period to prevent leakage.
6.3 Storage
Store the device in a clean, dry environment within the specified storage temperature range of -40℃ to +70℃ and relative humidity of 0-90% (dew-free). Use the provided fall-proof bag for protection during transport and storage.
6.4 Device Protection
The soft silicone design provides protection against minor impacts. However, avoid dropping the device from significant heights or exposing it to harsh physical shocks.

7. Troubleshooting
7.1 Common Issues
- No Power: Check if the 9V battery is correctly installed and has sufficient charge. Replace if necessary.
- Inaccurate Readings: Ensure optical connectors are clean and free of dust. Perform a self-calibration as per the instructions in the full manual. Verify that the correct adapter type is used for the fiber connection.
- No Signal Detected: Confirm that the fiber optic cable is properly connected to the correct input port (OLT or ONT) and that the light source is active.
7.2 Self-Calibration
If you suspect the device is providing inaccurate readings, utilize the self-calibration feature. Refer to the detailed instructions in the comprehensive manual for the exact procedure.
8. User Tips
- Portability: This device is designed for handheld use, making it convenient for field work.
- Accuracy: For best accuracy, ensure all fiber connections are clean and free of dust before testing.
- Battery Life: Always carry a spare 9V battery, especially for extended field operations, to avoid interruptions.
- Adapter Use: Always use the appropriate FC or SC adapter for your fiber connection to ensure a secure and accurate measurement.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.