YIDI STC-3028

Rate this product if you’ve used it
Contents

STC-3028 LED Digital Thermostat Temperature Humidity Controller

User Manual

1. Introduction

The YIDI STC-3028 is a versatile digital thermostat and hygrometer designed to control both temperature and humidity simultaneously. It features dual display windows for measured and set values, and can be configured for various applications including refrigeration/heating and humidification/dehumidification. This manual provides detailed instructions for its installation, operation, and maintenance.

YIDI STC-3028 Digital Thermostat and Hygrometer

Figure 1: YIDI STC-3028 Digital Thermostat and Hygrometer

2. Features

  • Controls temperature and humidity simultaneously.
  • Connects with humidifier and dehumidifier equipment.
  • Connects with refrigeration/heating and humidifier/dehumidifier equipment.
  • Separate heating/cooling functions to prevent violent changes.
  • Supports temperature and humidity calibration.
  • Dual display windows show measured and set temperature/humidity.

3. Specifications

ParameterValue
ModelSTC-3028
Input VoltageAC110~220V±10%, DC24V, DC12V
Measuring Temperature Range-20℃ to +80℃
Measuring Humidity Range00%RH to +100%RH
Accuracy±1℃, 0.1%RH
Relay Output Contact Capacity10A/240VAC
Sensor Length1m
Housing MaterialGray ABS flame retardant plastic shell
Mounting Hole Size71x29mm
Dimension (LxWxH)75x34.5x85mm
Display Size1.9 Inches & Under
CertificationCE
OriginMainland China
Battery IncludedNo
Is Smart DeviceNo
Dimensions of the STC-3028 controller

Figure 2: STC-3028 Controller Dimensions (75x34.5x85mm)

4. Setup

4.1 Unpacking

Carefully unpack the STC-3028 controller. Ensure all components are present:

  • 1x STC-3028 Temperature Humidity Controller
  • 1x Sensor (1m length)
  • 1x User Manual (this document)

4.2 Mounting

The controller is designed for panel mounting. The mounting hole size required is 71x29mm. Ensure adequate space for wiring and ventilation around the unit.

4.3 Wiring

Refer to the wiring diagrams below for proper connection. It is crucial to distinguish between the sensor down-lead, power wire, and output relay interfaces. Incorrect connections or overloading the relay can cause damage or safety hazards. Always ensure electricity is cut off before making any wire connections.

Back panel of STC-3028 showing wiring terminals

Figure 3: STC-3028 Wiring Terminal Layout

  • Terminals 1 & 2: Power supply (110-220VAC, 12V, or 24V)
  • Terminals 3 & 4: Humidity sensor connection
  • Terminals 5 & 6: 10A/220VAC output for humidity control (OUT %RH)
  • Terminals 7 & 8: 10A/220VAC output for temperature control (OUT °C)

Wiring Diagram 1: Independent Power Supply for Load

In this configuration, the load (heater/cooler) has its own separate power supply. The controller's relay acts as a switch for the load's power circuit.

Wiring diagram for STC-3028 with independent power supply for load

Figure 4: Wiring Diagram - Independent Load Power Supply

Wiring Diagram 2: Same Power Supply for Load

In this configuration, the controller and the load (heater/cooler) share the same power supply. The controller's relay directly switches the power to the load.

Wiring diagram for STC-3028 with same power supply for load

Figure 5: Wiring Diagram - Shared Load Power Supply

Note: Strictly distinguish the interface of relay, sensor, and power. Strictly distinguish the connection of sensor and power. The sensor down-lead and power wire should be kept a proper distance to avoid interference.

5. Operation

5.1 Panel Illustration

The front panel of the STC-3028 features two digital displays and four control buttons. The left display shows temperature, and the right display shows humidity.

Front panel illustration of STC-3028 with labeled indicators and buttons

Figure 6: STC-3028 Panel Layout

  • ① Temperature indicator
  • ② Humidity indicator
  • ③ Start temperature button (Up arrow for temperature)
  • ④ Stop temperature button (Down arrow for temperature)
  • ⑤ Temperature value display
  • ⑥ Humidity value display
  • ⑦ Start humidity button (Up arrow for humidity)
  • ⑧ Stop humidity button (Down arrow for humidity)

5.2 Key Operation Instructions

Checking Parameters

Under normal working status:

  • Press the "Up 1" button (top left arrow) to display the temperature setting value.
  • Press the "Down 1" button (bottom left arrow) to display the temperature difference value.
  • Press the "Up 2" button (top right arrow) to display the humidity setting value.
  • Press the "Down 2" button (bottom right arrow) to display the humidity difference value.

Setting Start/Stop Temperature (Humidity)

To set the start temperature (or humidity):

  1. Press the corresponding "Up" button once to display the current start temperature (or humidity).
  2. Long press the "Up" button for approximately 3 seconds until the display flashes.
  3. Use the "Up" and "Down" buttons to adjust the desired start value.

To set the stop temperature (or humidity):

  1. Press the corresponding "Down" button once to display the current stop temperature (or humidity).
  2. Long press the "Down" button for approximately 3 seconds until the display flashes.
  3. Use the "Up" and "Down" buttons to adjust the desired stop value.

Temperature/Humidity Correction

If the measured temperature/humidity differs from a known accurate reading, you can calibrate the sensor:

  1. Press the "Up" and "Down" buttons (either pair, e.g., both temperature buttons) simultaneously for about 3 seconds. The display will show "0.0".
  2. Use the "Up" and "Down" buttons to adjust the correction value. The final displayed value will be the tested value plus this correction value.
  3. Wait for 5 seconds after adjusting; the device will return to displaying real-time temperature/humidity with the correction applied.

Restoring System Data (Factory Reset)

To restore the controller to its factory default settings:

  • Under normal working status, press the "Down 1" and "Down 2" buttons (bottom left and bottom right arrows) together for 3 seconds.
  • The LED digital display will show "888", then return to test temperature, indicating that the system has been restored.

6. Safety Regulations

Danger

  • Strictly distinguish the sensor down-lead, power wire, and output relay interface from one another. Prohibit wrong connections or overloading the relay.
  • Prohibit connecting the wire terminals without electricity cut-off. Always disconnect power before wiring.

Warning

  • Do not use the machine in environments with excessive dampness, high temperatures, strong electromagnetic interference, or strong corrosion.

Notice

  • The power supply voltage must conform to the value indicated in the instruction (AC110~220V±10%, DC24V, or DC12V).
  • To avoid interference, the sensor down-lead and power wire should be kept at a proper distance from each other.

7. Maintenance

To ensure optimal performance and longevity of your STC-3028 controller, follow these maintenance guidelines:

  • Cleaning: Regularly wipe the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
  • Sensor Care: Keep the sensor clean and free from dust or debris. Avoid physical damage to the sensor. Ensure the sensor is placed in an area representative of the temperature and humidity you wish to measure and control.
  • Environmental Conditions: Operate the device within its specified environmental limits (temperature and humidity) to prevent damage.
  • Wiring Inspection: Periodically check all wiring connections for tightness and signs of wear or corrosion.

8. Troubleshooting

If you encounter issues with your STC-3028 controller, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Device not powering onNo power supply; incorrect voltage; loose wiring.Check power source; verify input voltage matches device requirements; inspect wiring connections.
Incorrect temperature/humidity readingsSensor dirty or damaged; sensor not properly connected; need for calibration.Clean sensor; check sensor wiring; perform temperature/humidity correction (see Section 5.2).
Load (heater/cooler/humidifier/dehumidifier) not activatingIncorrect set points; relay overloaded; faulty wiring to load; load itself is faulty.Verify start/stop temperature/humidity settings; ensure load current does not exceed 10A; check wiring to load; test load independently.
Display shows "888" or erratic behaviorSystem error; corrupted settings.Perform a system data restore (factory reset) as described in Section 5.2.

9. User Tips

Here are some tips for getting the most out of your STC-3028 controller:

  • Sensor Placement: For accurate readings, place the sensor in a location that best represents the average temperature and humidity of the area you wish to control, away from direct heat sources, cold drafts, or excessive moisture.
  • Differential Settings: Utilize the temperature and humidity difference settings to prevent rapid cycling of connected equipment, which can extend their lifespan.
  • Power Compatibility: Always double-check the input voltage requirement of your specific STC-3028 model (DC12V, DC24V, or AC110-220V) before connecting power.
  • Application Versatility: This controller is suitable for a wide range of applications, including cold storage, freezers, planting environments, aquaculture, hatcheries, and industrial machinery.
Examples of STC-3028 applications including cold storage, freezers, planting, aquaculture, hatcheries, and machinery

Figure 7: Typical Applications of the STC-3028 Controller

10. Warranty and Support

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

11. Product Video

Play video
Watch video online

Video 1: Overview of the STC-3028 Digital Thermostat and Hygrometer.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.