VEVOR Air Cooled Spindle Motor & VFD Inverter

Rate this product if you’ve used it
Contents

VEVOR Air Cooled Spindle Motor and Variable Frequency Drive (VFD) Inverter Instruction Manual

Models: 0.8KW, 1.5KW, 2.2KW, 4KW Spindle Motors & 1.5KW, 2.2KW, 3KW, 4KW VFD Inverters

1. Product Overview

This manual provides essential information for the safe and efficient operation of your VEVOR Air Cooled Spindle Motor and Variable Frequency Drive (VFD) Inverter. These units are designed for precision applications such as CNC engraving, milling, and grinding across various materials including wood, stone, acrylic, and metal.

VEVOR Air Cooled Spindle Motor and VFD Inverter

Figure 1: VEVOR Air Cooled Spindle Motor and VFD Inverter

Key Features

  • Dynamic Balance Technology: Reduces noise and extends service life.
  • Superior Performance Bearings: Imported bearings offer enhanced durability, anti-rust properties, high concentricity, and precision.
  • Anti-rust Material: Stainless steel casing and oxygen-free copper wire ensure durability and efficient heat dissipation.
  • High Concentricity & Precision: One-time molding design for excellent precision.
  • Premium Heat Dissipation: Scientifically designed fan for low noise and effective cooling.
  • Standard Collet Nuts: ER11, ER20, ER25 collet nuts made from manganese steel for high hardness, precision, and elasticity.
Wide Application of Spindle Motor

Figure 2: Wide Application for Jade Carving, Wood Carving, Acrylic Engraving, Wood Relief Carving, Poster Board Engraving, and Metal Mold Engraving.

2. Safety Instructions

  • Always wear appropriate personal protective equipment (PPE), including eye protection, when operating machinery.
  • Ensure the power supply is disconnected before performing any installation, maintenance, or troubleshooting.
  • Verify all wiring connections are secure and correct according to the wiring diagrams. Incorrect wiring can cause damage to the equipment or pose a safety hazard.
  • Do not operate the spindle motor without proper cooling.
  • Keep hands and loose clothing away from rotating parts.
  • Ensure the work area is clean, well-lit, and free from obstructions.
  • Only qualified personnel should perform installation and maintenance.

3. Setup and Installation

3.1 Spindle Motor Installation

  1. Mount the spindle motor securely to your CNC machine using appropriate brackets and fasteners. Ensure it is level and stable.
  2. Connect the spindle motor to the VFD Inverter using the provided aviation plug.
Spindle Motor Aviation Plug Connection Points

Figure 3: Spindle Motor Aviation Plug Connection Points. No. 1: Connect to U, No. 2: Connect to V, No. 3: Connect to W, No. 4: Connect to Ground or not.

3.2 VFD Inverter Wiring

Refer to the VFD's specific wiring diagram and the English manual included with your VFD for detailed connection instructions. Ensure the input voltage matches the VFD's requirements (AC 200-260V for 220V models). Connect the spindle motor's U, V, W terminals to the corresponding output terminals on the VFD.

3.3 VFD Parameter Configuration

The VFD must be configured to match the specifications of your spindle motor. This typically involves setting parameters such as:

  • Motor Power (KW): Match your spindle motor's power.
  • Max Output Frequency (Hz): Match your spindle motor's frequency (e.g., 400 Hz).
  • Rated Voltage (V): 220V.
  • Rated Current (A): Match your spindle motor's current.
  • Acceleration/Deceleration Time: Adjust for smooth startup and shutdown.
  • Control Mode: Vector control or V/F control, depending on your application and VFD capabilities.

Consult the VFD's English manual for a complete list of parameters and their recommended settings for spindle motor operation. Incorrect parameter settings can lead to poor performance or damage.

4. Operating Instructions

  1. Power On: Ensure all connections are secure. Turn on the main power supply to the VFD.
  2. VFD Display: The VFD display should show the current operating frequency or a standby indicator.
  3. Start Spindle: Use the VFD's control panel (RUN button) or your CNC controller to start the spindle. Gradually increase the frequency/speed to the desired RPM.
  4. Monitor Operation: Observe the spindle motor for unusual noises, vibrations, or excessive heat. Ensure the air cooling system is functioning correctly.
  5. Adjust Speed: Adjust the spindle speed as needed for your machining operation via the VFD or CNC controller.
  6. Stop Spindle: Use the VFD's control panel (STOP button) or your CNC controller to stop the spindle. Allow the spindle to come to a complete stop before touching it or changing tools.

4.1 Collet and Tool Changing

  1. Ensure the spindle is completely stopped and power is off.
  2. Use the appropriate wrenches to loosen the collet nut.
  3. Remove the old tool and insert the new tool into the collet.
  4. Tighten the collet nut firmly with the wrenches. Do not overtighten.
Standard ER11 Collet Nut

Figure 4: Standard ER11 Collet Nut, highlighting high hardness, precision, and elasticity.

5. Maintenance

  • Regular Cleaning: Keep the spindle motor and VFD free from dust and debris. Regularly clean the cooling fins and fan vents to ensure optimal airflow.
  • Bearing Inspection: Listen for any unusual noises from the spindle bearings. While designed for longevity, bearings may eventually require replacement.
  • Collet Maintenance: Keep collets clean and free of chips. Replace worn or damaged collets to maintain tool concentricity and prevent tool slippage.
  • Wiring Check: Periodically inspect all wiring for signs of wear, damage, or loose connections.
  • Environmental Conditions: Ensure the operating environment for the VFD is within specified temperature and humidity ranges (14~104℉/-10 ~ 40 ℃, 10-95% RH without dew).

6. Troubleshooting

Common Issues and Solutions

ProblemPossible CauseSolution
Spindle not rotating / No powerNo power to VFD, incorrect VFD parameters, loose wiring.Check power supply, verify VFD input/output wiring, review VFD parameters.
Excessive noise or vibrationUnbalanced tool, worn bearings, loose mounting, incorrect VFD settings.Check tool balance, inspect bearings, tighten mounting bolts, verify VFD parameters.
Spindle overheatingBlocked cooling vents, fan malfunction, prolonged heavy load, incorrect VFD settings.Clean vents, check fan operation, reduce load, verify VFD parameters.
VFD displays error codeVarious internal faults, overcurrent, overvoltage, undervoltage.Consult the VFD manual for specific error code meanings and troubleshooting steps.
Difficulty with Mach3/GRBL controlIncompatible control board, incorrect wiring, software configuration issues.Ensure your control board is compatible with the VFD. Verify wiring between control board and VFD. Check Mach3/GRBL software settings for spindle control.

7. Specifications

7.1 Spindle Motor Specifications

Parameter0.8KW Spindle1.5KW Spindle2.2KW Spindle (ER11)2.2KW Spindle (ER20)4KW Spindle (ER25)
Power0.8 KW1.5 KW2.2 KW2.2 KW4 KW
Voltage220V~250V220V220V220V220V
Frequency400 Hz200-400 Hz200-400 Hz400 Hz300 Hz
Speed0-24000 R/min12000-24000 R/min12000-24000 R/min24000 R/min18000 R/min
Runout off< 0.005 mm< 0.002 mm< 0.002 mm< 0.002 mm< 0.002 mm
Max Torque0.6NM1.1NM1.7NM1.2NM2.1NM
Collet SizeER11 (3.175, 4, 6 mm)ER11ER11ER20 (3.175-12.7 mm)ER25
BearingsN/AN/AN/A7005 x 2, 7002 x 27003 x 2, 7007 x 2
Dimensions (L x Dia.)180 x 65 mm (7.1 x 2.6 in)239 x 65 mm (9.4 x 2.6 in)299 x 80 mm (11.8 x 3.1 in)261 x 62 mm (10.3 x 2.4 in)339 x 75 mm (13 x 3 in)
Weight2.7 KG (5.95 lbs)3.5 kg (7.7 lbs)6 kg (13.2 lbs)6 kg (13.2 lbs)8.5 kg (18.7 lbs)
0.8KW Spindle Motor Dimensions and Specifications

Figure 5: 0.8KW Spindle Motor Dimensions and Specifications.

7.2 VFD Inverter Specifications

Parameter1.5KW VFD (A2-8015)2.2KW VFD (A2-8022)3KW VFD (A2-8030)4KW VFD (A2-8040)
Power1.5 kW2.2 kW3 kW4 kW
Input VoltageAC 200-260VAC 200-260VAC 200-260VAC 200-260V
Output VoltageAC 220VAC 220VAC 220VAC 220V
Input Current7.5A10A20A18A
Output Current10A15A20A26.7A
Input Phase1 or 3 Phase1 or 3 Phase1 or 3 Phase1 or 3 Phase
Output Phase3 Phase3 Phase3 Phase3 Phase
Input Frequency45-65 Hz45-65 Hz45-65 Hz45-65 Hz
Output Frequency0.1-400 Hz0.1-400 Hz0.1-400 Hz0.1-400 Hz
Horsepower2 HP3 HP4 HP5 HP
Working Temperature14~104℉/-10 ~ 40 ℃14~104℉/-10 ~ 40 ℃14~104℉/-10 ~ 40 ℃14~104℉/-10 ~ 40 ℃
Humidity10-95% RH (without dew)10-95% RH (without dew)10-95% RH (without dew)10-95% RH (without dew)
Vibration0.4 G0.4 G0.4 G0.4 G
Net Weight0.88 kg (1.94 lbs)0.95 kg (2.1 lbs)1.58 kg (3.48 lbs)2.22 kg (4.9 lbs)
Dimensions (L x W x H)140 x 82 x 114 mm (5.5 x 3.2 x 4.5 in)140 x 82 x 114 mm (5.5 x 3.2 x 4.5 in)170 x 125 x 163 mm (6.7 x 4.9 x 6.4 in)220 x 150 x 180 mm (8.7 x 5.9 x 7.1 in)

8. User Tips

  • VFD Configuration: It is highly recommended to verify that the VFD is correctly configured for your specific spindle motor before first use. This includes matching power, frequency, and voltage settings. Refer to the VFD's manual for detailed parameter setup.
  • Compatibility: If integrating with CNC control software like Mach3 or GRBL, ensure your control board is compatible with the VFD and that all wiring and software settings for spindle control are correctly configured.
  • Aviation Plug: Pay close attention to the aviation plug connections on the spindle motor. Ensure pins U, V, W are correctly wired to the VFD output and that the ground connection is properly handled.
  • Initial Run: For the first few hours of operation, run the spindle at lower speeds to allow the bearings to break in.

9. Warranty and Support

VEVOR products are designed for durability and performance. For warranty information, technical support, or service inquiries, please refer to the official VEVOR website or contact their customer service directly. Keep your purchase receipt as proof of purchase.

© 2023 VEVOR. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.