1. Introduction
The Yieryi EC-3185 3-in-1 EC/TDS/CF Soil Tester is a high-quality instrument designed for measuring the electrical conductivity (EC), total dissolved solids (TDS), and conductivity factor (CF) in soil. This device is ideal for various applications including gardening, greenhouse planting, orchard cultivation, farmland management, laboratory use, and breeding farms. Maintaining optimal soil EC, TDS, and CF levels is crucial for healthy plant growth, as these parameters directly influence nutrient availability and overall soil health. The EC-3185 helps users monitor these vital soil characteristics to ensure appropriate nutrient solutions and growing conditions.

2. Product Overview
The EC-3185 Soil Meter features a user-friendly design with a clear digital display and intuitive controls. It comes with a high-quality, rust-proof, and corrosion-resistant probe suitable for various soil types.
2.1. Components and Controls

- Display Screen: Shows measurement readings.
- MODE Key: Toggles between EC, CF, and TDS measurement modes.
- HOLD Key: Freezes the current reading on the display.
- ON/OFF Button: Powers the device on or off.
- High Quality Probe: The sensing element for soil measurements.

3. Specifications
| Parameter | Value |
|---|---|
| Measuring Range (EC) | 0.00~4.00 mS/cm |
| Measuring Range (CF) | 0.0~4.00 CF |
| Measuring Range (TDS) | 10~4000 ppm |
| Resolution (EC) | 0.01 mS/cm |
| Resolution (CF) | 0.01 CF |
| Resolution (TDS) | 10 ppm |
| Accuracy (EC) | ±2% F.S |
| Automatic Temperature Compensation (ATC) | 0~50℃ |
| Power Supply | 4 x 1.5V (AG13) batteries (not included) |
| Operating Temperature | 0~50℃ |
| Calibration | Manual, one-point via trimmer |
| Dimensions | 170mm x 35mm x 35mm |
| Weight | 100g |
| Display Type | DIGITAL |
| Is Smart Device | No |
| With Backlight Or Not | No |
| Certification | CE |
4. Setup
4.1. Battery Installation
The EC-3185 Soil Meter requires 4 x 1.5V (AG13) batteries, which are not included in the package. To install or replace batteries:
- Unscrew the battery compartment cap located at the top of the meter.
- Insert four new 1.5V (AG13) batteries, ensuring correct polarity (+/-).
- Securely screw the battery compartment cap back on.
If the meter cannot be switched on or the display fades, check the battery voltage. Replace the batteries if the voltage is lower than 4.5V.
5. Operating Instructions
Follow these steps to take measurements with your EC-3185 Soil Meter:
- Remove the protective cap from the probe.
- Turn the meter on by pressing the ON key.
- Insert the probe into the soil to the desired depth. If the soil is dry, saturate it with deionized water to ensure proper contact. Alternatively, immerse the electrode in the solution to be tested.
- Wait for the reading on the display to stabilize.
- Press the MODE key to cycle through the measurement types: EC, CF, and ppm (TDS). The selected mode will be shown on the display.
- To hold the current reading, press the HOLD key. To release the hold and resume live measurement, press the HOLD key again.
- After use, turn the meter off by pressing the OFF key.
- Rinse the electrode with distilled water to minimize contamination and ensure accurate future readings.
- Always replace the protective cap on the probe after use to protect it.

5.1. Understanding Measurements
- EC (Electrical Conductivity): Measures the total concentration of soluble salts in the soil. High EC can indicate excessive fertilizer or salinity.
- CF (Conductivity Factor): Another unit for measuring conductivity, often used in hydroponics.
- TDS (Total Dissolved Solids): Represents the total amount of mobile charged ions, including minerals, salts, or metals dissolved in a given volume of water. Lower TDS values generally indicate less heavy metal ion solubility.



6. Calibration
Regular calibration ensures the accuracy of your EC-3185 Soil Meter. The device requires a one-point manual calibration using a trimmer.
- Turn on the meter.
- Immerse the meter's probe in a 12880 µS/cm (12.88 mS/cm) EC calibration solution.
- Unscrew the battery compartment cap on the top of the meter to access the calibration trimmer.
- Allow the reading to stabilize. Using a small screwdriver, carefully turn the calibration trimmer until the display shows "12.88 EC".
- Rinse the electrode with distilled water and gently blot it dry with tissue paper.
- To verify, immerse the electrode in a 1413 µS/cm (1.41 mS/cm) calibration solution. Gently shake it and wait for a stable display. The displayed value should be within the acceptable error range of the buffer solution's value.
- The calibration is now complete. Securely screw the battery compartment cap back on.

7. Maintenance
7.1. Cleaning and Storage
- Always rinse the probe with distilled water after each use to prevent contamination and residue buildup.
- Gently blot the probe dry with a clean, soft cloth or tissue. Do not rub vigorously.
- Ensure the protective cap is securely placed back on the probe when not in use.
- Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
7.2. Battery Replacement
Refer to Section 4.1 for detailed instructions on battery replacement. Always use four new 1.5V (AG13) batteries and ensure correct polarity.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not turn on | Dead or incorrectly installed batteries | Check battery polarity; replace all four 1.5V (AG13) batteries. |
| Display fades or is dim | Low battery power | Replace all four 1.5V (AG13) batteries. |
| Inaccurate or unstable readings |
|
|
| Meter does not read fluids (e.g., calibration solution) |
|
|
9. User Tips
- Calibration Solution: Calibration solutions (e.g., 12880 µS/cm and 1413 µS/cm EC solutions) are essential for accurate calibration and are typically sold separately. Ensure you acquire the correct solutions for your meter.
- Soil Moisture: For accurate soil measurements, ensure the soil is moist enough for the probe to make good contact. If the soil is too dry, readings may be inconsistent or inaccurate.
- Language Support: While this manual is in English, some users may require instructions in other languages. Check the manufacturer's website or contact customer support for additional language options if available.
- Probe Care: The probe is a critical component. Handle it with care, avoid bending or damaging it, and always keep it clean and capped when not in use.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase or visit the official Yieryi website. Keep your purchase receipt as proof of purchase for any warranty claims.