1. Product Overview
The FC-7668Pro is a sophisticated 4G GSM Wired Alarm System designed for industrial and comprehensive security applications. It supports multiple zone types, including wired, wireless, and bus expansion zones, offering extensive coverage and control capabilities. The system integrates network, GSM, and PSTN communication for reliable alarm reporting and remote management via Web IE and mobile applications.
2. Setup and Installation
2.1 Unboxing and Initial Inspection
Carefully unpack all components and verify against the package contents list:
- Control Panel main board with Cabinet (x1)
- Wired Touch LCD Control Keypad (x1)
- AC/AC Transformer (x1)
- Accessories: Antenna (x1), EOL Resistors (x1 bag)
Note: Backup battery is not included and must be purchased separately.
2.2 SIM Card Installation
Warning: Insert the SIM card before powering on the device.
The system supports one SIM card. For 4G versions, use SIM Card 2 slot. The 2G version does not support 4G SIM cards.
2.3 Wiring Connections
Refer to the detailed wiring diagram for connecting power, zones, and peripherals. Ensure all connections are secure before applying power.
The following images provide visual guidance for internal wiring:
Video demonstrating the wiring process for the alarm system.
2.4 Power Connection
Connect the DC15V/2.5A switching power supply to the control panel. If using a backup battery (12VDC, 7Ah sealed lead-acid), ensure it is connected. If no siren is used, connect a 2.2K resistor to clear any siren fault indications.
2.5 App Download and Installation
Download the 'Smart Security' app to manage your alarm system remotely. Scan the QR codes below or search for 'Smart Security' in your app store.
3. Operating Instructions
3.1 Web IE Introduction and Login
To access the system's Web IE interface, open your internet browser and input the IP address of the alarm control panel. The default administrator username is 'admin' and the password is '012345'.
After logging in, you will see the main menu:
3.2 System Arm/Disarm
You can arm or disarm the system via the Web IE interface or the mobile app. Select the desired area and click the corresponding Arm/Disarm icon.
3.3 Zone Settings
Configure individual zones through the Web IE interface or the mobile app. This includes setting zone type, name, area assignment, and siren behavior.
3.4 Alert Settings
When an alarm is triggered, the system can upload to the alarm platform, make voice calls, send SMS, and send emails. Select the desired actions and save the settings.
Notice: Email function is not supported at present.
3.5 Timing Arm/Disarm
Set fixed times to arm or disarm partitions. The system supports four groups of timing arm/disarm schedules, which can be assigned to specific areas.
3.6 Remote Phone Control (GSM)
You can control the alarm system by calling its GSM number. Follow the voice prompts and input the password (default factory password: 1234) to perform actions like arming, disarming, checking system status, or controlling appliances.
3.7 Alarm Receiving Phone Operation
When an alarm occurs, the panel will dial pre-set voice phone numbers. Upon answering, you will hear a recorded voice message. Press '1' to cancel the alarm or '4' to disarm the system. The panel will continue to call other pre-set numbers if the call is not answered or the alarm is not canceled.
3.8 Camera Binding
Camera binding is performed after cameras have been added to the mobile application. The system supports up to 32 Meian cameras. Once bound, the associated zone will automatically display video when triggered.
4. Maintenance
4.1 Battery Maintenance
If using a 12VDC, 7Ah sealed lead-acid backup battery, it should be replaced every 3-5 years to ensure optimal performance during power outages. The maximum charging current for the battery is 350mA.
4.2 General Care
Keep the control panel and all components clean and free from dust. Avoid exposing the system to extreme temperatures, humidity, or direct sunlight. Ensure proper ventilation around the control panel.
5. Troubleshooting
5.1 Siren Fault
If you are not using a siren, connect a 2.2K resistor to the siren terminals to prevent a siren fault indication on the system.
5.2 Device Status Monitoring
The Web IE interface provides a 'Device Status' section to monitor the connection status of various components like AC power, alarm platform, backup battery, Internet, GSM, PSTN, and wired siren. A green circle indicates connected, a red circle indicates a fault, and 'X' means the item is unsupported.
5.3 Connectivity Issues
Check the 'Network and Internet' section in the Web IE to verify current network IP address and gateway information. Ensure your internet connection is stable for remote access and platform communication.
6. Specifications
| Feature | Specification |
|---|---|
| Model Number | FC-7668Pro ABS plastic shell |
| Brand Name | FOCUS |
| Zone Number | 8 wired zone + 32 wireless zone + 88 wired bus zone (expandable to 512 channels) |
| Kit Configuration | Door/Window Sensor (typical) |
| Size | 25X19X3CM |
| Communication Interface | Wireless |
| Arming Type | APP |
| Video Interface | No |
| Display | Yes |
| Password Keyboard | Yes |
| Alarm Type | SMS, PSTN, Apps Control, The Alarm |
| Power (W) | 15V 2A |
| Output Number | 12V |
| Certification | CE, FCC, RoHS |
| Color | Grey |
| Network Support | TCP/IP GSM And PSTN 3 network in 1, TCP IP RJ45 + 4G Network SIM Card |
| Frequency | 433Mhz (also 868Mhz variant available) |
| Protocol | SIA2013 and CID Protocol |
| Network | TCP/IP RJ 45 Ethernet Port |
| Max current of battery | 350Am |
| App name | Smart Security |
7. User Tips
- App Selection: The system primarily uses the 'Smart Security' app. Ensure you download the correct version for your device.
- Roller Shutter Contacts: The system is capable of recognizing fast contacts, such as those used for roller shutters, for effective security monitoring.
- SIM Card Compatibility: Double-check that your SIM card is compatible with the system's 4G capabilities, especially if you have the 4G version.
- Default Passwords: Remember to change default passwords (e.g., Web IE admin password '012345') immediately after initial setup for enhanced security.
8. Warranty and Support
For detailed warranty information, please refer to the product's official documentation or contact your retailer. For technical support and video tutorials, you can visit the official YouTube channel by searching for 'FC7668'.
A comprehensive user manual in PDF format is also available online: FC-7668 User Manual PDF