FOCUS FC-7668Pro

Contents

FC-7668Pro 4G GSM Wired Alarm System User Manual

Model: FC-7668Pro

1. Product Overview

The FC-7668Pro is a sophisticated 4G GSM Wired Alarm System designed for industrial and comprehensive security applications. It supports multiple zone types, including wired, wireless, and bus expansion zones, offering extensive coverage and control capabilities. The system integrates network, GSM, and PSTN communication for reliable alarm reporting and remote management via Web IE and mobile applications.

FC-7668Pro 4G GSM Wired Alarm System with Keypad and Remote Controls
FC-7668Pro 4G GSM Wired Alarm System with Keypad and Remote Controls.
System architecture diagram showing connections for wired/wireless zones, motion detectors, door sensors, cameras, and communication pathways (PSTN, 2G/4G, LAN, APP).
System architecture diagram illustrating the comprehensive connectivity of the FC-7668Pro alarm panel.

2. Setup and Installation

2.1 Unboxing and Initial Inspection

Carefully unpack all components and verify against the package contents list:

  • Control Panel main board with Cabinet (x1)
  • Wired Touch LCD Control Keypad (x1)
  • AC/AC Transformer (x1)
  • Accessories: Antenna (x1), EOL Resistors (x1 bag)

Note: Backup battery is not included and must be purchased separately.

Contents of the FC-7668Pro package, including the control panel, keypad, transformer, and accessories.
Package contents of the FC-7668Pro system.

2.2 SIM Card Installation

Warning: Insert the SIM card before powering on the device.

The system supports one SIM card. For 4G versions, use SIM Card 2 slot. The 2G version does not support 4G SIM cards.

Close-up of the SIM card slot on the FC-7668Pro circuit board, indicating 4G support.
Close-up view of the SIM card slot on the main board.

2.3 Wiring Connections

Refer to the detailed wiring diagram for connecting power, zones, and peripherals. Ensure all connections are secure before applying power.

Detailed wiring diagram for the FC-7668Pro alarm panel, showing connections for SIM cards, power, zones, and peripherals.
Detailed wiring diagram for the FC-7668Pro control panel.

The following images provide visual guidance for internal wiring:

Close-up view of the FC-7668Pro main circuit board, showing components and connection points.
Main circuit board layout.
Angled view of the FC-7668Pro circuit board with wires connected to terminal blocks.
Angled view of the circuit board with example wiring.
Hand demonstrating connection of wires to the FC-7668Pro circuit board.
Demonstration of wire connection to the terminal blocks.

Video demonstrating the wiring process for the alarm system.

2.4 Power Connection

Connect the DC15V/2.5A switching power supply to the control panel. If using a backup battery (12VDC, 7Ah sealed lead-acid), ensure it is connected. If no siren is used, connect a 2.2K resistor to clear any siren fault indications.

2.5 App Download and Installation

Download the 'Smart Security' app to manage your alarm system remotely. Scan the QR codes below or search for 'Smart Security' in your app store.

QR codes for downloading the 'Smart Security' app on Android and iPhone, along with the app icon.
QR codes for Android and iPhone app download, and the app icon.

3. Operating Instructions

3.1 Web IE Introduction and Login

To access the system's Web IE interface, open your internet browser and input the IP address of the alarm control panel. The default administrator username is 'admin' and the password is '012345'.

Screenshot of the Web IE login interface, showing fields for username and password.
Web IE login interface.

After logging in, you will see the main menu:

Screenshot of the Web IE main menu with icons for various settings like remote control, password, CMS, network, system options, wireless device, zone settings, event log, remote upgrade, and alert settings.
Web IE main menu.

3.2 System Arm/Disarm

You can arm or disarm the system via the Web IE interface or the mobile app. Select the desired area and click the corresponding Arm/Disarm icon.

Screenshot of the Web IE interface for system arming, disarming, and stay arming across different areas.
System Arm/Disarm options in Web IE.

3.3 Zone Settings

Configure individual zones through the Web IE interface or the mobile app. This includes setting zone type, name, area assignment, and siren behavior.

Screenshot of the Web IE interface showing a table for detailed zone settings, including zone code, name, type, area, siren, chime, and operation.
Detailed zone settings table in Web IE.
Screenshots of the mobile app interface for configuring zone settings and binding devices like cameras.
Mobile app interface for zone settings.

3.4 Alert Settings

When an alarm is triggered, the system can upload to the alarm platform, make voice calls, send SMS, and send emails. Select the desired actions and save the settings.

Screenshot of the Web IE interface for configuring alert settings, including alert type, associated actions (upload to platform, voice call, SMS, email).
Alert settings configuration in Web IE.

Notice: Email function is not supported at present.

3.5 Timing Arm/Disarm

Set fixed times to arm or disarm partitions. The system supports four groups of timing arm/disarm schedules, which can be assigned to specific areas.

Screenshot of the Web IE interface for configuring timed arm/disarm schedules across different areas.
Timed Arm/Disarm settings in Web IE.

3.6 Remote Phone Control (GSM)

You can control the alarm system by calling its GSM number. Follow the voice prompts and input the password (default factory password: 1234) to perform actions like arming, disarming, checking system status, or controlling appliances.

Diagram illustrating remote phone control via GSM, including dialing the alarm panel's GSM number and voice prompts for system control.
Remote phone control via GSM.

3.7 Alarm Receiving Phone Operation

When an alarm occurs, the panel will dial pre-set voice phone numbers. Upon answering, you will hear a recorded voice message. Press '1' to cancel the alarm or '4' to disarm the system. The panel will continue to call other pre-set numbers if the call is not answered or the alarm is not canceled.

Diagram showing the process of receiving an alarm call and interacting with the system via phone keypad inputs.
Alarm receiving phone operation.

3.8 Camera Binding

Camera binding is performed after cameras have been added to the mobile application. The system supports up to 32 Meian cameras. Once bound, the associated zone will automatically display video when triggered.

Screenshots of the mobile app showing the process of binding cameras to the alarm system.
Mobile app interface for camera binding.

4. Maintenance

4.1 Battery Maintenance

If using a 12VDC, 7Ah sealed lead-acid backup battery, it should be replaced every 3-5 years to ensure optimal performance during power outages. The maximum charging current for the battery is 350mA.

4.2 General Care

Keep the control panel and all components clean and free from dust. Avoid exposing the system to extreme temperatures, humidity, or direct sunlight. Ensure proper ventilation around the control panel.

5. Troubleshooting

5.1 Siren Fault

If you are not using a siren, connect a 2.2K resistor to the siren terminals to prevent a siren fault indication on the system.

5.2 Device Status Monitoring

The Web IE interface provides a 'Device Status' section to monitor the connection status of various components like AC power, alarm platform, backup battery, Internet, GSM, PSTN, and wired siren. A green circle indicates connected, a red circle indicates a fault, and 'X' means the item is unsupported.

Screenshot showing the 'Data Kanban' for real-time alarm data and 'Device Status' indicating connection status of AC, platform, battery, internet, GSM, PSTN, and wired siren.
Device Status display in Web IE.

5.3 Connectivity Issues

Check the 'Network and Internet' section in the Web IE to verify current network IP address and gateway information. Ensure your internet connection is stable for remote access and platform communication.

Screenshot of the Web IE interface displaying network IP address and gateway information.
Network and Internet information in Web IE.

6. Specifications

Feature Specification
Model Number FC-7668Pro ABS plastic shell
Brand Name FOCUS
Zone Number 8 wired zone + 32 wireless zone + 88 wired bus zone (expandable to 512 channels)
Kit Configuration Door/Window Sensor (typical)
Size 25X19X3CM
Communication Interface Wireless
Arming Type APP
Video Interface No
Display Yes
Password Keyboard Yes
Alarm Type SMS, PSTN, Apps Control, The Alarm
Power (W) 15V 2A
Output Number 12V
Certification CE, FCC, RoHS
Color Grey
Network Support TCP/IP GSM And PSTN 3 network in 1, TCP IP RJ45 + 4G Network SIM Card
Frequency 433Mhz (also 868Mhz variant available)
Protocol SIA2013 and CID Protocol
Network TCP/IP RJ 45 Ethernet Port
Max current of battery 350Am
App name Smart Security

7. User Tips

  • App Selection: The system primarily uses the 'Smart Security' app. Ensure you download the correct version for your device.
  • Roller Shutter Contacts: The system is capable of recognizing fast contacts, such as those used for roller shutters, for effective security monitoring.
  • SIM Card Compatibility: Double-check that your SIM card is compatible with the system's 4G capabilities, especially if you have the 4G version.
  • Default Passwords: Remember to change default passwords (e.g., Web IE admin password '012345') immediately after initial setup for enhanced security.

8. Warranty and Support

For detailed warranty information, please refer to the product's official documentation or contact your retailer. For technical support and video tutorials, you can visit the official YouTube channel by searching for 'FC7668'.

A comprehensive user manual in PDF format is also available online: FC-7668 User Manual PDF

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.