RuoShui Victor 02S

Contents

VICTOR 02S RTD Calibrator User Manual

Model: Victor 02S | Brand: RuoShui

1. Introduction

The VICTOR 02S is a standard precision multifunction loop process signal and thermal resistance meter, designed for accurate measurement and simulation of various electrical and temperature signals. This calibrator is a versatile tool for professionals in electrical and measurement fields, offering high precision and ease of use.

VICTOR 02S Digital Temperature Calibrator

Figure 1: VICTOR 02S Digital Temperature Calibrator

2. Product Features

  • High Precision Output: Achieves an output accuracy of 0.05%, with a 5-digit display.
  • Versatile Measurement: Capable of measuring thermal resistance and standard resistance.
  • Signal Output: Provides output for thermal resistance and standard resistance.
  • RTD Compatibility: Supports 2-wire, 3-wire, and 4-wire systems for 7 types of thermal resistance (Pt10, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50) and resistance (400Ω, 4000Ω).
  • RTD Simulation: Simulates 7 types of thermal resistance (Pt10, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50) output.
  • Thermocouple Simulation: Can measure/output 11 kinds of thermocouple signals (R, S, K, E, J, T, N, B, A, C, D).
  • Fast Response: Current excitation source response time is less than 5ms, suitable for pulsed current excitation from DCS, PLC, and temperature logging devices.
  • Temperature Units: Display can be switched between Celsius (℃) and Fahrenheit (℉).
  • User-Friendly Operation: Output set values can be adjusted bit by bit for simple and quick operation.
  • Convenient Power: Powered by 3 AAA alkaline batteries for easy replacement.
  • Additional Functions: Includes flashlight lighting, low battery indicator, backlight function, automatic shut-down, and data retention (HOLD).
High-precision digital measurement and CE certification

Figure 2: High-Precision Digital Measurement and Certification

3. Package Contents

The standard package for the VICTOR 02S RTD Calibrator includes the following items:

  • Packing Box
  • VICTOR 02S Temperature Calibrator (Main Unit)
  • Alligator Clips
  • Industrial Test Leads
  • Latch Key / Cloth Bag
  • Thermocouple Conversion Plug / Product Manual
  • User Manual
  • Test Report
Packaging accessories for VICTOR 02S

Figure 3: Typical Packaging Accessories

4. Panel Introduction

Familiarize yourself with the various components and controls on the calibrator's panel:

Detailed Panel Introduction of VICTOR 02S

Figure 4: Front Panel Layout and Controls

  1. LCD display screen
  2. Configuration button
  3. Power on/off button
  4. Input/output state switching button
  5. Input/output function switching button
  6. Output setting button
  7. Input terminal for all measurement (+)
  8. 4-wire resistance measurement high-end SENSE terminal
  9. 4-wire resistance measurement low-end SENSE terminal / 3-wire resistance measurement SENSE terminal
  10. Common (-) (return) terminal for all inputs
  11. Temperature compensation on/off button
  12. Backlight/flashlight button
  13. ZERO button
  14. Select input/output range button
  15. Output terminal for all outputs (+)
  16. Common (-) (return) terminal for all outputs

5. Setup

5.1 Battery Installation

The VICTOR 02S calibrator requires three 1.5V AAA batteries for operation. To install or replace batteries:

  1. Ensure the device is powered off.
  2. Locate the battery compartment on the back of the calibrator.
  3. Open the battery compartment cover.
  4. Insert three 1.5V AAA batteries, ensuring correct polarity (+/-).
  5. Close the battery compartment cover securely.
Battery compartment and flashlight details

Figure 5: Battery Compartment and Flashlight

6. Operating Instructions

6.1 General Operation

  • Power On/Off: Press the power button (3) to turn the device on or off.
  • Backlight/Flashlight: Press the backlight/flashlight button (12) to activate the display backlight or the integrated flashlight.
  • ZERO Function: Use the ZERO button (13) to clear or reset readings as needed.
  • Data Hold: The device features a data retention (HOLD) function to freeze the current reading on the display.
  • Automatic Shut-down: The calibrator is equipped with an automatic shut-down feature to conserve battery life.
  • Low Battery Indicator: A 'low pressure tips' icon will appear when batteries need replacement.

6.2 Measurement Functions

The VICTOR 02S can measure various electrical and temperature parameters. Refer to the panel diagram (Figure 4) for terminal connections.

Schematic Diagram of Wire Connection for Measurements

Figure 6: Schematic Diagram of Wire Connection for Measurements

  • DC Voltage, Thermocouple, Thermal Resistance, and Resistance (2-wire): Connect the test leads as shown in the diagram (top right of Figure 6).
  • Resistance, RTD Measurement (3-wire): Connect the test leads to the 3W and COM terminals as shown (bottom left of Figure 6).
  • Resistance, RTD Measurement (4-wire): Connect the test leads to the 4W and COM terminals, utilizing the high-end and low-end SENSE terminals as shown (bottom right of Figure 6).

6.3 Signal Sourcing/Output Functions

The calibrator can simulate various signals for testing and calibration purposes.

6.3.1 Thermal Resistance (RTD) Simulation

The device can simulate 5 types of thermal resistance signals:

Simulate 5 Kinds of Thermal Resistance

Figure 7: Thermal Resistance Simulation Types and Ranges

  • Pt100: -200.0°C to 800.0°C
  • Cu50: -50.0°C to 150.0°C
  • Pt200: -200.0°C to 630.0°C
  • Pt500: -200.0°C to 630.0°C
  • Pt1000: -200.0°C to 630.0°C

6.3.2 Thermocouple (TC) Simulation

The device can simulate 11 types of thermocouple signals:

Simulate 11 Thermocouples

Figure 8: Thermocouple Simulation Types and Ranges

  • R: 0°C to 1767°C
  • S: 0°C to 1767°C
  • K: -200°C to 1372°C
  • E: -200°C to 1000°C
  • J: -200°C to 1200°C
  • T: -250°C to 400°C
  • N: -200°C to 1300°C
  • B: 600°C to 1820°C
  • A: 0°C to 2500°C
  • C: 0°C to 2310°C
  • D: 0°C to 2310°C

7. Specifications

7.1 Input Measurement Function

Used within one year after calibration, 23°C±5°C, 20-70% RH. Accuracy = ± (% set value + reading).

  • Uncertainty: Includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
  • Display Refresh Rate: 2-3 times / second.
  • Maximum Applied Voltage at Input Terminal: 60 Vpk.
  • Input Common-Mode Rejection: 50Hz / 60 Hz > 80 dB.
  • Input Serial-Mode Rejection: 50Hz / 60 Hz > 40 dB.
  • Temperature Coefficient: 0.1 × basic accuracy / °C (temperature range < 18°C or > 28°C).
Table 1: Input Measurement Specifications
MeasurementRangeMeasuring rangeResolutionAccuracy
DCV100mV-110.000mV~110.000mV0.01mV0.05%+0.03mV
1V-1.1000V~1.1000V0.0001V0.05%+0.3mV
30V-30.000V~30.000V0.001V0.02%+2mV
OMH500Ω0~550.00Ω0.01Ω0.05%+0.2Ω
5.500KΩ0~5.5000KΩ0.0001KΩ0.05%+2Ω
TCR0°C~1767°C1°C0°C~500°C : 2.5°C
500°C~1767°C : 2°C
S0°C~1767°C1°C0°C~1000°C : 1.2°C
1000°C~1767°C : 1.2°C
K-100.0°C~1372°C0.1°C-200.0°C~0°C : 0.5°C
0°C~1372°C : 0.4°C
E-50.0°C~1000°C0.1°C-200.0°C~0°C : 0.6°C
0°C~1000°C : 0.4°C
J-60.0°C~1200°C0.1°C-200.0°C~0°C : 0.7°C
0°C~1200°C : 0.7°C
T-100.0°C~400.0°C0.1°C-250.0°C~0°C : 0.9°C
0°C~400.0°C : 0.8°C
N-200.0°C~1300.0°C0.1°C-200.0°C~0°C : 0.9°C
0°C~1300.0°C : 0.9°C
B600°C~1820°C1°C600°C~800°C : 1.4°C
800°C~1820°C : 1.2°C
A0°C~2500°C1°C0°C~1600°C : 2.0°C
1600°C~2500°C : 2.0°C
C0°C~2310°C1°C0°C~270°C : 2.4°C
270°C~2310°C : 2.2°C
D0°C~2310°C1°C0°C~270°C : 2.4°C
270°C~2310°C : 2.2°C
RTD (3W)Pt100(385)-200°C~800°C0.1°C-200°C~0°C : 0.8°C
0°C~800°C : 0.7°C
Pt200(385)-200°C~630°C0.1°C-200°C~0°C : 0.7°C
0°C~630°C : 0.7°C
Pt500(385)-200°C~630°C0.1°C-200°C~0°C : 0.7°C
0°C~630°C : 0.7°C
Pt1000(385)-200°C~630°C0.1°C-200°C~0°C : 0.7°C
0°C~630°C : 0.7°C
Cu50-50°C~150°C0.1°C-50.0°C~150.0°C : 0.6°C
On/off detection500Ω≤500Ω sounding0.01Ω

7.2 Analog Output Function

Used within one year after calibration, 23°C±5°C, 20-70% RH. Accuracy = ± (% set value + reading).

  • Uncertainty: Includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
  • Maximum Applied Voltage at Output Terminal: Approximately 30Vpk.
  • Maximum Output Current at Output Terminal: Approximately 25mA.
  • Output Terminal Protection: 100mA fuse.
  • Temperature Coefficient: 0.1 × basic accuracy / °C (temperature range < 18°C or > 28°C).
Table 2: Analog Output Specifications
OutputRangeOutput rangeResolutionAccuracy
DCV100mV0~110.000mV0.01mV0.05%+0.03mV
1V0~1.1000V0.0001V0.05%+0.3mV
30V0~30.000V0.001V0.02%+2mV
OMH400Ω0Ω~400.0Ω0.1Ω0.05%+0.2Ω
4KΩ0~4.000KΩ1Ω0.05%+2Ω
TCR0°C~1767°C1°C0°C~100°C : 1.5°C
100°C~1767°C : 1.2°C
S0°C~1767°C1°C0°C~100°C : 1.2°C
100°C~1767°C : 1.2°C
K-200.0°C~1372.0°C0.1°C-200.0°C~0°C : 0.5°C
0°C~1372.0°C : 0.4°C
E-200.0°C~1000.0°C0.1°C-200.0°C~0°C : 0.6°C
0°C~1000.0°C : 0.4°C
J-200.0°C~1200.0°C0.1°C-200.0°C~0°C : 0.7°C
0°C~1200.0°C : 0.7°C
T-250.0°C~400.0°C0.1°C-250.0°C~0°C : 0.9°C
0°C~400.0°C : 0.8°C
N-200.0°C~1300.0°C0.1°C-200.0°C~0°C : 0.9°C
0°C~1300.0°C : 0.9°C
B600°C~1820°C1°C600°C~800°C : 1.4°C
800°C~1820°C : 1.2°C
A0°C~2500°C1°C0°C~1600°C : 2.0°C
1600°C~2500°C : 2.0°C
C0°C~2310°C1°C0°C~270°C : 2.4°C
270°C~2310°C : 2.2°C
D0°C~2310°C1°C0°C~270°C : 2.4°C
270°C~2310°C : 2.2°C
RTDPt100(385)-200.0°C~800.0°C0.1°C-200.0°C~0°C : 0.8°C
0°C~800.0°C : 0.7°C
Pt200(385)-200.0°C~630.0°C0.1°C-200.0°C~0°C : 0.7°C
0°C~630.0°C : 0.7°C
Pt500(385)-200.0°C~630.0°C0.1°C-200.0°C~0°C : 0.7°C
0°C~630.0°C : 0.7°C
Pt1000(385)-200.0°C~630.0°C0.1°C-200.0°C~0°C : 0.7°C
0°C~630.0°C : 0.7°C
Cu50-50.0°C~150.0°C0.1°C-50.0°C~150.0°C : 0.6°C

8. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the calibrator in a dry, dust-free environment away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods.
  • Calibration: For optimal accuracy, periodic calibration by qualified personnel is recommended.

9. Troubleshooting

If you encounter issues with your VICTOR 02S calibrator, consider the following general troubleshooting steps:

  • No Power: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • Inaccurate Readings: Verify correct wiring connections for the specific measurement or output. Ensure the device is within its specified operating temperature and humidity ranges. Consider if recalibration is needed.
  • Display Issues: If the display is dim, activate the backlight. If the display is blank or erratic, try replacing the batteries.
  • No Output: Check the output settings and ensure the correct function is selected. Verify connections to the device being calibrated.

For persistent issues, contact customer support or refer to the full product manual if available.

10. User Tips

  • Always ensure proper terminal connections for accurate and safe operation.
  • Utilize the backlight function in low-light conditions for better readability.
  • Take advantage of the data hold feature to record stable readings.
  • Keep spare AAA batteries on hand for uninterrupted use.

11. Warranty & Support

RuoShui (Victor) instruments are guaranteed to be 100% genuine and original.

  • Product Warranty: A 1-year warranty is provided for all products, excluding items damaged and/or misused after receipt.
  • Accessories Warranty: Accessories come with a 3-month warranty.
  • Defective Items: Defective items must be reported and returned within the warranty period and in their original packaging.
  • Battery Policy: Batteries are not included with the product due to safety regulations during shipping.

For any issues or support inquiries, please contact the seller directly.

Warranty and Guarantee Information

Figure 9: Warranty and Guarantee Details

12. Production Overview

The VICTOR 02S calibrator is manufactured with attention to detail in a clean and professional working environment. Assembly workers operate with precision and care to ensure product quality.

Video 1: Production process of the VICTOR 02S calibrator.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.