LAUNCH O2-2 Scope Box

Contents

LAUNCH X431 O2-2 Scope Box Automotive Oscilloscope Tool

Model: O2-2 Scope Box | Brand: LAUNCH

1. Introduction

1.1 Product Overview

The LAUNCH X431 O2-2 Scope Box is an advanced add-on module designed for automotive diagnostics. It functions as an oscilloscope and automotive ignition waveform analyzer, enabling auto repair technicians to quickly identify faults in electronic equipment and wiring. The device integrates with LAUNCH X-431 series scan tools via the O2-2 application, providing accurate and conclusive diagnostic data.

The oscilloscope measures and analyzes five key parameters: amplitude (maximum voltage), frequency (cycle time), waveform shape, pulse width (duty cycle or time range), and array (repetition characteristic). This allows for the detection of circuit faults in sensors, actuators, circuits, and electronic control units.

1.2 Important Safety and Operation Information

To prevent personal injury, property loss, or damage to the product, adhere to the following safety guidelines:

  • Handle Device Carefully: Do not drop, bend, puncture, insert foreign objects, or place heavy objects on the device. Internal fragile components may be damaged.
  • Connect and Disconnect Properly: Do not connect or disconnect probes or test leads while they are connected to a voltage source.
  • Observe All Terminal Ratings: To avoid fire or shock hazards, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections.
  • Use Proper Probe: To avoid shock hazards, use a properly rated probe for your measurement.
  • Avoid Circuit or Wire Exposure: Do not touch exposed connections and components when power is on.
  • Do Not Operate With Suspected Failures: If suspected damage occurs, have the device inspected by qualified service personnel.
  • Environmental Conditions: Do not operate in wet/damp conditions or an explosive atmosphere.
  • Maintenance: Keep product surfaces clean and dry. Do not disassemble or refit the device; all internal repairs must be carried out by authorized personnel. Do not attempt to replace the internal battery.

Precautions for Vehicle ECU Operation

When performing diagnostic operations on a vehicle equipped with an ECU, observe the following:

  • Do not disconnect vehicle internal electrical units when the ignition switch is on, as this can generate high instantaneous voltage and damage sensors/ECU.
  • Avoid placing magnetic objects (e.g., radio speakers) near the computer, as magnets can damage ECU circuits.
  • Disconnect the ECU system power supply when welding on the vehicle.
  • When working near a computer or sensor, take care to avoid damage to the ECU and sensor.
  • Ground yourself when disassembling programmable ROM to prevent static electricity damage to ECU circuits.
  • Test ECU and sensors with a high-impedance digital meter, not a pointer ohmmeter, unless otherwise specified.
  • Do not use test lamps for ECU-related electrical units to prevent damage, unless otherwise noted.
  • Wear a grounded metal strap when performing maintenance on or near the digital meter controlled by the ECU to prevent electrostatic discharge.
  • Ensure the ECU harness connector is reliably connected to avoid damage to electronic components.

2. Components & Controls

2.1 Accessory Checklist

The following accessories are typically included with your O2-2 Scope Box. Note that accessories may vary by region.

Complete kit contents for LAUNCH X431 O2-2 Scope Box, including cables, probes, and attenuators.
Figure 2.1: Complete LAUNCH O2-2 Scope Box Kit Contents
No.NameDescription
1BNC to 4mm Test LeadsTest lead with a male BNC connector to two 4mm connectors (black for earth wire, red for positive pole). Used for testing various signal types and compatible with the 20:1 Attenuator.
220:1 AttenuatorAllows the Scopebox to measure fuel injector and primary ignition waveforms. Not for high voltage measurements other than these specific applications.
3Battery Clamps CableSupplies power to the Scopebox by connecting to the vehicle's battery.
4Secondary Ignition Pick-upUsed for secondary-distributor, secondary-simultaneous, and secondary-direct ignition analysis. Features a BNC connector, crocodile clip (grounding), and high-voltage clip with an attenuator.
5Multimeter ProbesDesigned to connect to bare terminals or leads.
6Crocodile ClipsUsed for connecting to terminals or leads.
7Back Probe Pins SuiteUsed for piercing the insulation of wires for automotive electrical measurements without causing damage. Can also be used as pin-tip probes for small circuit boards.
8USB CableConnects the Scopebox to the diagnostic tool for signal display.
9User ManualProvides detailed instructions for operation.
106-way Breakout Leads (Optional)Each lead has 6 blades wired to 6 sockets, allowing insertion between a plug and socket pair. Used for testing most sensors and actuators.
11COP (Coil-on-Plug) Extension Cord (Optional)Allows accurate secondary ignition measurements on secondary-direct (Coil-on-Plug) ignition systems.
12CC-650 AC/DC Current Clamp (Optional)Measures current waveforms (AC/DC) up to 650A. Frequency range: Up to 400Hz.
13CC-65 AC/DC Current Clamp (Optional)Measures current waveforms (AC/DC) up to 65A. Frequency range: Up to 20 kHz.

2.2 Device Components and Controls

Diagram showing USB interface and DC IN charging port on the LAUNCH O2-2 Scope Box.
Figure 2.2: LAUNCH O2-2 Scope Box Front and Rear Panels
No.NameDescription
1CH2Channel 2 input
2CH1Channel 1 input
3CH4Channel 4 input
4CH3Channel 3 input
5Fixed Signal GeneratorGenerates a square signal with fixed 1K frequency for probe compensation.
6Working LEDIlluminates solid green when powered up. Flashes when communicating with the diagnostic tool. Flashes faster if an error occurs.
7B-shaped USB PortConnects to the diagnostic tool via USB cable.
8DC IN PortProvides power via the battery clamps cable.

3. Setup

3.1 Getting Started

To begin, tap the O2-2 application icon on your diagnostic tool. The main application screen will appear, providing access to various functions and settings.

3.2 Probe Compensation

This function matches the characteristics of the probe and the channel input, ensuring measurement accuracy. Uncompensated probes can lead to measurement tolerance or error.

  1. Power the Scopebox: Plug one end of the battery clamps cable into the DC-IN port of the Scopebox. Clamp the other two terminals to the vehicle's battery (Red to +, Black to -). Note: This step is only necessary if the diagnostic tool cannot provide sufficient power via USB.
  2. Connect to Diagnostic Tool: Connect the B-shaped plug of the USB cable to the Scopebox's USB port, and the other end to the diagnostic tool's USB port.
  3. Launch Application: Run the Scopebox App on your diagnostic tool.
  4. Set Probe Attenuation: From the "Vertical Setting" panel, select the corresponding channel and set the Probe attenuation to 10X.
  5. Connect Probe: Set the switch on the probe to "X10" (default is X1) and connect it to CH1 of the Scopebox. Attach the probe tip to the Probe Compensator and the ground clip to the ground connector.
  6. Auto-Set: Tap the "Auto" button on the screen. A square wave (approx. 1KHz 2V peak-to-peak) should be displayed.
  7. Check Waveform: Verify the shape of the displayed waveform. If necessary, use a non-metallic tool to adjust the trimmer capacitor of the probe for the fattest square wave.
  8. Repeat for CH2, CH3, and CH4.

3.3 Self-Calibration

The self-calibration routine optimizes the oscilloscope signal path for maximum measurement accuracy. Run this routine if the ambient temperature changes by 10°C or more. For accurate calibration, power on the Scopebox and wait twenty minutes for it to warm up.

  1. Disconnect Probes: Disconnect any probes or cables from the input connectors.
  2. Access Self Adjust: Go to Menu -> UserSetting, then tap "Self Adjust".
  3. Start Calibration: Tap "OK" on the message box. The Scopebox LED will flash, and a "Self Adjust is running" message will appear. A lock icon will indicate that no operations are allowed during calibration.
  4. Completion: The routine takes several minutes. Upon completion, "Self Adjust is successful" will pop up, and the lock icon will disappear.

3.4 Connection Methods

Connection methods vary depending on the application. The following steps are common to all scenarios:

Connection diagram for powering the Scope Box via battery clamps and connecting to diagnostic tool via USB.
Figure 3.1: Basic Power and USB Connection
  1. Power the Scopebox: Plug one end of the battery clamps cable into the DC-IN port of the Scopebox. Clamp the other two terminals to the vehicle's battery (Red to +, Black to -). Note: This connection is only required if the diagnostic tool cannot provide enough power via USB. PADVII series tablets support USB power supply.
  2. Connect USB Cable: Connect the B-shaped plug of the USB cable to the USB port of the Scopebox, and the other end to the USB port of the diagnostic tool.

A. While testing sensors or actuators:

  1. Connect the BNC connector of the BNC to 4mm test lead to CH1/CH2/CH3/CH4.
  2. Plug the red (SIGNAL) 4mm connector into one of the back probe pins.
  3. Pierce the back probe pin through the signal wire of the vehicle sensor.

Alternatively, using 6-way breakout leads (optional):

  • Connect the BNC connector of the BNC to 4mm test lead to CH1/CH2/CH3/CH4.
  • Plug the black (GND) and red (SIGNAL) 4mm connectors into the Black (GND) and other color (SIGNAL) banana sockets of the 6-way breakout leads.
  • Connect the black terminal and signal wire of the 6-way breakout lead to the GND and signal terminal of the vehicle sensor.

B. While testing Secondary-distributor ignition analysis / Secondary-simultaneous ignition analysis:

Diagram showing secondary ignition pick-up connection to high-voltage line and ground.
Figure 3.2: Secondary Ignition Pick-up Connection
  1. Connect the BNC connector of the secondary ignition pick-up to any channel of the Scopebox.
  2. Clamp the crocodile clips and high-voltage clips onto the vehicle ground and high-voltage line respectively.

C. While testing Secondary-direct ignition analysis:

Diagram showing ignition coil, COP earth cord, and spark plug connections.
Figure 3.3: Direct Ignition Analysis Connection
  1. If high-voltage wire is exposed: Plug the BNC end of secondary ignition pick-up into CH1/CH2/CH3/CH4 channel of Scopebox. Connect the high-voltage clip to the high-voltage line, and crocodile clips to ground.
  2. If no high-voltage wire is exposed: Dismantle the ignition coil of the tested cylinder. Connect one end of the COP extension cord to the ignition coil (grounded via COP earth cord), and insert the other end into the cylinder to join with the spark plug. Then plug the BNC end of secondary ignition pick-up into CH1/CH2/CH3/CH4 channel of Scopebox, and connect the high-voltage clip to the high-voltage line, and crocodile clips to ground.

4. Operation

4.1 Channel Selection

The Scopebox supports 4 channels (CH1, CH2, CH3, CH4) by default. MATH and REF channels are also available. Channels can be selected by tapping the channel tab on the right edge of the screen. Each channel and waveform are marked in different colors for easy identification.

4.2 Channel Attributes & Trigger Setting

Channel attributes can be configured via horizontal and vertical settings.

4.2.1 Horizontal Settings

Adjust the horizontal time/division scale by tapping the corresponding button or selecting a value from the pull-down list. This expands or compresses the waveform when acquisition is stopped.

4.2.2 Vertical Settings

The trigger determines when the Scopebox acquires and displays a waveform. Proper trigger setup is crucial for stable and meaningful waveform displays. The Scopebox collects data before and after a trigger event to draw the waveform.

Options for vertical settings include:

  • Invert: Turns the displayed waveform 180 degrees.
  • Couple: Determines which part of the signal (AC or DC) passes to the trigger circuit.
  • Probe Type: Selects between Voltage (Vol) and Current (Cur) probes. The system automatically configures attenuation.
  • Bandwidth: Selects the desired bandwidth.

4.2.3 Trigger Setting

Trigger settings define the conditions under which the Scopebox acquires and displays a waveform. Access these settings via Menu -> Trigger.

Sweep Mode: Determines Scopebox behavior without a trigger event. Options include:

  • Auto: Acquires waveforms even without a trigger. If no trigger occurs, it forces a trigger.
  • Normal: Acquires waveforms only when triggered. If no trigger occurs, the previous waveform remains.

Trigger Types:

  • Edge Trigger: Determines trigger point on rising, falling, or dual edges of a signal.
  • Pulse Width Trigger: Detects abnormal signals based on pulse width conditions.

4.3 Auto-Set

The Auto-Set feature automatically configures the Scopebox to display the input signal optimally. It adjusts vertical and horizontal scaling, trigger coupling, position, slope, level, and mode settings.

4.4 Menu Operations

The Menu provides access to various functions:

  • Measure: Provides 23 parametric auto measurements (e.g., Period, Frequency, Rise Time, Fall Time, PK-PK, RMS, Mean). Up to 10 items can be selected and displayed.
  • Save: Saves the current waveform as a reference waveform (.WAV or .CSV) for future comparison.
  • Display: Sets the display mode of the waveform, including horizontal reference, brightness, and graticule settings (Full, Grid, Retical, Frame).
  • UserSetting: Configures system settings such as storage depth, factory reset, self-adjust, and save/recovery of system setups.
  • About: Displays detailed information about the application.

4.5 Automotive Operations

This function provides various testing applications for automotive parts (circuits, sensors, actuators, ignition, etc.) and detailed connection methods. Select the desired automotive part, and the system will automatically configure preset parameters.

4.6 Zoom

The Zoom mode allows you to analyze collected waveform data in detail. It provides a main window and a Zoom window, displaying a selected segment of the main waveform in magnified view. This function applies only to acquired or stopped data.

4.7 Cursor Operations

The Cursor function assists in measurements. It provides horizontal and vertical cursors to measure values in the vertical and horizontal directions respectively. Cursors can be fine-tuned or dragged to specific points on the waveform.

4.8 Quick Save

This function quickly saves the currently running measurement waveform. It can save analog or math channel waveforms to local storage as .WAV or .CSV files. The Scopebox provides 4 reference (REF) channels (R1, R2, R3, R4) to load and display saved waveforms.

4.9 MATH & REF

This function allows for mathematical operations and reference waveform loading.

4.9.1 MATH

The MATH function enables addition, subtraction, multiplication, division, and FFT (Fast Fourier Transform) functions to operate and analyze waveforms. The MATH channel becomes the current channel, and its marker appears on the screen.

4.9.2 REF

The REF function allows you to load reference waveforms from R1/R2/R3/R4. Saved waveforms can be recalled from local folders or external storage devices.

4.10 Phase Ruler

The Phase Ruler helps measure the timing of cyclic waveforms. You can set the number of cylinders and angle, then drag two phase rulers to mark the start and end of a loop. The ruler displays the phase start point (0°) and end point (e.g., 720° for a four-stroke cylinder).

4.11 Ignition Analysis

The ignition system significantly impacts engine performance. The O2-2 Scope Box can test and analyze secondary signals for various engine ignition systems, including distributor, independent, and simultaneous ignition systems.

5.1 Secondary-distributor ignition analysis

This analysis involves connecting the secondary ignition pick-up to a Scopebox channel and clamping clips to the vehicle ground and high-voltage line. Normal ignition waveforms show distinct phases like contact break point, ignition voltage, spark voltage, ignition voltage pulse, spark line, and contact point close. Primary ignition waveforms show voltage oscillation, damped oscillation, and make contact magnetizing period.

5.2 Secondary-simultaneous ignition analysis

Similar connection to secondary-distributor analysis. Valid ignition shows higher breakdown and spark voltage due to fresh combustible mixture gas, while invalid ignition shows lower values.

5.3 Secondary-direct ignition analysis

Connection depends on whether the high-voltage wire is exposed. If exposed, connect the secondary ignition pick-up directly. If not, dismantle the ignition coil and use a COP extension cord. Normal direct ignition waveforms show no obvious oscillations in primary voltage during magnetization, but voltage increases due to current limiting.

5.4 Waveform analysis mode

This mode is used to:

  • Analyze ignition dwell angle (ignition coil charging time).
  • Analyze ignition coil and secondary high tension circuit capability.
  • Identify improper mixture A/F ratio.
  • Analyze capacitance capability.
  • Find spark plug misfires.

Observe the consistency of flashover voltage, spark/combustion voltage, and combustion line. Analyze ignition coil oscillation and primary voltage waveforms for diagnostic insights.

5. Specifications

Detailed technical specifications table for LAUNCH O2-2 Scope Box.
Figure 5.1: LAUNCH X431 O2-2 Technical Parameters
ItemRange
Channels4
Bandwidth100MHz
Rising Time≤3.5ns (typical)
Max. Sample Rate1G (for four channels)
Input Impedance1MΩ±1.5%
Storage Depth10M (for four channels)
Sample Bit8bit
DC Gain Accuracy±3%
Vertical Scale5mV~10V
Vertical Offset Range±2.5V (probe switch "x1", <500mV/div), ±120V (probe switch "x1", ≥500mV/div)
InvertSupport
CouplingDC, AC
Timebase1ns~1ks
Timebase Precision20ppm
Acquisition ModeNormal
Line DecodingCAN, LIN
Trigger TypeEdge, Pulse width
Trigger ModeNormal, Auto and Single SEQ
Trigger CouplingDC, Noise rejection
DisplayYT, Zoom, Roll
Roll Mode200ms/div~1000s/div
Auto SetSupport
Auto Measurement Items23
CursorHorizontal cursor, Vertical cursor
Power InterfaceUSB port, DC IN port
Data Exchange ViaUSB
Compatible Operating SystemAndroid
AutomotiveCircuits, sensor, actuators, ignition
Working Temperature0℃~50℃
Storage Temperature-20℃~60℃

5.2 Physical Dimensions

  • Length: 43 cm
  • Width: 13 cm
  • Height: 36 cm
  • Weight: 5.0 kg

6. Care & Maintenance

6.1 General Care

Do not store or leave the Scopebox where it will be exposed to direct sunlight for long periods. To avoid damage to the device or probes, do not expose them to sprays, liquids, or solvents.

6.2 Cleaning

Inspect the device and probes as often as operating conditions require. Ensure the device is disconnected from all power sources before cleaning.

  1. Remove loose dust on the outside of the Scopebox and probes with a lint-free cloth. Use care to avoid scratching the clear glass display filter.
  2. Use a soft cloth dampened with water to clean the device.

Caution: Do not use any abrasive or chemical cleaning agents to avoid damage to the surface of the device or probes.

7. Troubleshooting: Ignition Waveform Analysis

The O2-2 Scope Box provides detailed waveform analysis to help diagnose common ignition system faults. Below are common issues and their waveform indicators:

7.1 Primary Voltage Waveform Faults

  • Capacitor Leakage: Damped attenuation cycles are reduced on the spark period, and amplitude is lower.
  • Insufficient Spring Force: Irregular beating during the contact closing period.
  • Too Large Contact Gap: Small contact angle during the magnetizing period.
  • Poor Grounding: A lot of clutter displayed on the horizontal section of the primary waveform.
  • Electronic Ignition System Fault (Low-Voltage): Voltage does not rise during magnetizing, indicating a limitation effect or component failure (e.g., ignition coils, igniter, signal generator, cam position sensor).

7.2 Secondary Faulty Waveform Examples

Secondary waveforms are affected by various factors including spark plugs, combustion process, mixture gas composition, and ignition coil thermal state. Common indicators of secondary faults include:

  • Spark plug issues: Overheated spark plug, value guide leakage, carbon attachment, or incorrect gap.
  • Mixture Ratio Problems: Too rich or too lean mixture, or low cylinder pressure.
  • Distributor Issues: Distributor cover or lead matched un-tightly.
  • Primary Circuit Reverse: Indicated by an inverted primary circuit waveform.
  • Ignition Coil/Capacitor Leakage: Shows specific leakage patterns.
  • Open Primary Lead: Indicated by an open primary lead of the ignition coil.
  • Secondary Circuit Cut-off Intermittently: Shows intermittent signal loss.
  • Secondary Coil Leakage Voltage: Specific voltage patterns indicating leakage.
  • Open Secondary Circuit: Complete loss of secondary signal.
  • Too Large Secondary Resistance: Indicated by specific waveform characteristics.

8. User Tips

  • Initial Inspection: Upon receiving your O2-2 Scope Box, ensure it is well-packed and all components are present and working correctly.
  • Model Verification: Always verify the specific model (e.g., O2-2, 4-channel) and its compatibility with your diagnostic tool before purchase or use.
  • Compatibility Check: Confirm that your LAUNCH X431 diagnostic tool model (e.g., PAD V Elite, PRO3S+, V5.0) is compatible with the O2-2 Scope Box. Note that it is not compatible with X431 Pro5.
  • Power Supply: For optimal performance, ensure the Scope Box receives adequate power, either via the battery clamps cable or, if supported, directly from your diagnostic tablet's USB port (e.g., PADVII series).

9. Warranty & Support

9.1 Warranty Information

LAUNCH electronic products are warranted against defects in materials and workmanship for one year from the date of delivery to the user. This warranty is limited to persons who purchase LAUNCH products for resale or use in the ordinary course of business.

The warranty does not cover parts that have been abused, altered, used for unintended purposes, or used inconsistently with instructions. The exclusive remedy for a defective automotive meter is repair or replacement. LAUNCH is not liable for consequential or incidental damages.

Final determination of defects is made by LAUNCH. No agent, employee, or representative has the authority to bind LAUNCH to any affirmation, representation, or warranty beyond what is stated herein.

9.2 Disclaimer

The above warranty is in lieu of any other warranty, expressed or implied, including any warranty of merchantability or fitness for a particular purpose.

9.3 Customer Service

For any questions during operation or if your unit requires repair service, please contact LAUNCH customer service. If the unit is under warranty, it will be repaired or replaced at no charge. Out-of-warranty repairs will incur a nominal service charge plus return freight.

Contact Information:
Phone: 86-755-84557891
Address: LAUNCH TECH CO., LTD., Launch Industrial Park, North of Wuhe Avenue, Banxuegang, Bantian, Longgang, Shenzhen, Guangdong, P.R.China, 518129
Website: www.cnlaunch.com, www.x431.com

Note: Launch reserves the right to change product design and specifications without prior notice. The appearance and color of the actual product may differ from those shown in this manual.

10. Frequently Asked Questions (FAQ)

Q: Which LAUNCH X431 diagnostic tool models are compatible with the O2-2 Scope Box?
A: The LAUNCH O2-2 Scope Box is compatible with a wide range of LAUNCH X431 devices, including: X431 PAD V Elite, X431 PAD VII Elite, PAD III, DBScar VII Device, X431 PRO ELITE, Pros V5.0 Pro3s+, Pro TT, Pro3 ACE, Pro Dyno, Pro3 APEX, Launch V 5.0, X431 V+, X431 Pad II AE, X431 Torque, X431 Turbo, X431 Throttle, IMMO Series (X431 IMMO Elite, X431 IMMO PLUS), and Creader Series (CRP919X BT, CRP919E BT). Please note that the O2-2 Scope Box cannot be used with X431 Pro5.
Q: What are the key specifications of the O2-2 Scope Box?
A: The O2-2 Scope Box features 4 channels, a bandwidth of 100MHz, a rising time of ≤3.5ns (typical), and a maximum sample rate of 1G (for four channels). It has an input impedance of 1MΩ±1.5% and a storage depth of 10M (for four channels). The device operates on Android and connects via USB.
Q: How do I power the O2-2 Scope Box?
A: You can power the Scope Box using the provided battery clamps cable, connecting it to your vehicle's battery (red to positive, black to negative). Alternatively, if your diagnostic tablet supports it (e.g., PADVII series), you can power it directly via the USB connection.