1. Introduction

The keepLiNK KP-9000-45-5TX is a compact, unmanaged 5-port industrial Ethernet switch designed for robust performance in harsh environments. It supports IEEE 802.3 and IEEE 802.3u/x standards with 10/100M full/half-duplex operation and MDI/MDI-X auto-sensing. Featuring 12-58 VDC redundant power inputs, this switch ensures reliable operation. It complies with FCC, RoHS, and CE standards and is suitable for maritime, rail wayside, highway, and mobile applications.

The KP-9000-45-5TX operates within a wide temperature range of -30°C to 75°C and includes DIP switches for configuring broadcast storm protection and port isolation, offering enhanced flexibility for industrial automation control applications.

2. Safety Information

  • Always ensure the power supply voltage is within the specified range (12-58 VDC).
  • Do not expose the device to moisture or extreme temperatures outside its operating range.
  • Ensure proper grounding to prevent electrical hazards.
  • Do not open the device casing; refer servicing to qualified personnel.
  • Disconnect power before cleaning or performing any maintenance.

3. Package Contents

Verify that your package contains the following items:

  • keepLiNK KP-9000-45-5TX Industrial Ethernet Switch
  • DIN-rail mounting kit
  • Terminal block connector for power input
  • User Manual (this document)

4. Product Overview

The keepLiNK KP-9000-45-5TX is an unmanaged industrial Ethernet switch featuring 5 RJ45 ports. Its robust design includes a semi-aluminum housing and fanless operation, making it ideal for demanding industrial environments.

4.1. Key Features

  • 5 x 10/100BaseT(X) RJ45 ports
  • IEEE 802.3/802.3u/802.3x support
  • MDI/MDI-X auto-sensing
  • 12-58 VDC redundant power inputs
  • DIP switches for Broadcast Storm Protection and Port Isolation
  • DIN-rail mounting
  • IP40 protection rating
  • Wide operating temperature range: -30°C to 75°C
  • Semi-aluminum housing, fanless design
  • 5-year warranty

4.2. Product Views

Front view of the keepLiNK Industrial Ethernet Switch mounted on a DIN rail.
Front view of the Industrial Ethernet Switch mounted on a DIN rail.
Side view of the keepLiNK Industrial Ethernet Switch showing DIP switches and power input.
Side view showing DIP switches and power input.
Back view of the keepLiNK Industrial Ethernet Switch showing certifications.
Back view with certifications.
Top view of the keepLiNK Industrial Ethernet Switch.
Top view of the switch.

4.3. Internal Components and Quality

The switch is built with brand-new branded electronic components, including a branded fuse, power chip, surge arrester, and capacitor, all integrated into a 4 to 6 layer PCB for enhanced reliability and performance. It is equipped with an industrial-grade Marvell chip for fast and reliable data processing.

Exploded view showing branded electronic components: fuse, power chip, surge arrester, capacitor, and 4-6 layer PCB.
Quality Assurance of Electronic Components.
Close-up of the industrial-grade intelligent Marvell chip inside the switch.
Industrial-grade Intelligent Chip.

4.4. Product Animation

Watch this 3D animation to see the industrial switch's features and internal components.

5. Setup Instructions

5.1. Mounting the Switch

The KP-9000-45-5TX is designed for DIN-rail mounting (DIN35mm). Attach the provided DIN-rail clip to the back of the switch and secure it onto a standard DIN rail in your industrial cabinet or enclosure.

Front view of the keepLiNK Industrial Ethernet Switch mounted on a DIN rail.
Switch mounted on a DIN rail.

5.2. Power Connection

The switch supports 12-58 VDC redundant power inputs (PWR1 and PWR2) via a 3-contact terminal block. Connect your DC power sources to the terminal block, ensuring correct polarity. The redundant inputs allow for continuous operation even if one power source fails.

Diagram illustrating redundant power supply connections.
Redundant Power Supply connection diagram.

5.3. Network Connection

Connect your Ethernet devices (e.g., PLCs, cameras, computers) to the RJ45 ports (1-5) using standard Ethernet cables. The switch supports MDI/MDI-X auto-sensing, so you don't need to worry about straight-through or crossover cables.

5.4. DIP Switch Configuration

The switch features DIP switches for advanced configuration:

  • Broadcast Storm Protection: Enable or disable this feature to prevent network congestion caused by excessive broadcast traffic.
  • Port Isolation: Enable or disable port isolation to restrict communication between specific ports, enhancing security and network segmentation.

Refer to the markings on the switch for the exact position and function of each DIP switch. Ensure power is disconnected before changing DIP switch settings.

Product display image showing front, side, back, and top views with labels for RJ45 ports, 3-contact terminal block, and DIP switch.
Product display with labels for ports, terminal block, and DIP switch.

6. Operating Instructions

6.1. Power On

Once the power supply is connected, the switch will automatically power on. The power indicator LEDs (P1, P2) will illuminate to indicate active power inputs.

6.2. Network Operation

The KP-9000-45-5TX is an unmanaged switch, meaning it operates automatically without requiring any software configuration. Simply connect your Ethernet devices to the RJ45 ports. The corresponding port LEDs will light up when a valid link is established and will flash to indicate data activity.

6.3. LED Indicators

  • P1/P2 (Power): Indicates power status for redundant inputs. Lit when power is supplied.
  • Port LEDs (1-5):
    • Solid Green: A valid network link is established.
    • Flashing Green: Data activity on the port.
    • Off: No link or device connected.

7. Maintenance

7.1. Cleaning

To clean the switch, disconnect power and use a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure no dust accumulates in the ventilation fins of the housing.

7.2. Environmental Considerations

The switch is designed for industrial environments with an IP40 rating, protecting against solid objects larger than 1mm. While robust, avoid exposing it to direct water spray or prolonged high humidity. Ensure the operating temperature remains within -30°C to 75°C.

Image detailing standard industrial grade design, temperature range, IP40, DIN35mm mounting, 5-year warranty, MTBF, and semi-aluminum housing.
Standard Industrial Grade Design features.

8. Troubleshooting

  • No Power: Check power connections to the terminal block. Verify that the 12-58 VDC power supply is active and correctly wired. Check the P1/P2 LEDs.
  • No Link on Port: Ensure the Ethernet cable is securely connected to both the switch and the connected device. Verify the connected device is powered on and functioning correctly. Try a different Ethernet cable or port.
  • Network Performance Issues:
    • If experiencing slow speeds or intermittent connectivity, check the DIP switch settings for Broadcast Storm Protection and Port Isolation. Incorrect settings might impact network traffic.
    • Ensure cables are not damaged and are within the maximum recommended length for Ethernet (100 meters).
  • Device Not Recognized: Ensure the connected device's network settings are correct (e.g., IP address, subnet mask).

9. Specifications

FeatureDescription
Model NumberKP-9000-45-5TX
Brand NamekeepLiNK
Switch TypeFast Switch (Unmanaged Industrial Ethernet Switch)
Number of Interfaces5 x RJ45 Ports
Transmission Rate10/100Mbps
Communication ModeFull-Duplex & Half-Duplex
Switch Capacity1G
VLAN SupportYes (via Port Isolation DIP switch)
Power Input12-58 VDC (Redundant)
Operating Temperature-30°C to 75°C
IP RatingIP40
HousingSemi-Aluminum, Fanless
MountingDIN-rail (DIN35mm)
MTBF100,000 Hrs
CertificationsCE, FCC, RoHS, CCC
PackageYes
OriginMainland China
Dimensions (L x W x H)20 cm x 18 cm x 8 cm (approximate)
Weight0.55 kg (approximate)
Product display image showing front, side, back, and top views with labels for RJ45 ports, 3-contact terminal block, and DIP switch, including dimension diagrams.
Product dimensions and component layout.

10. User Tips

  • For optimal performance in noisy industrial environments, use high-quality shielded Ethernet cables.
  • Regularly check the status LEDs to monitor network connectivity and power status.
  • When using redundant power, ensure both power sources are from different circuits if possible, to maximize uptime in case of a power failure.
  • Consider the placement of the switch to ensure adequate airflow, even though it is fanless, to maintain optimal operating temperature.

11. Warranty and Support

The keepLiNK KP-9000-45-5TX Industrial Ethernet Switch comes with a 5-year warranty, reflecting its high quality and durability. For technical assistance, troubleshooting, or any inquiries, please contact the keepLiNK Official Store's skilled technical support team. They also offer free design services for networking applications.

11.1. Certifications

The product has undergone rigorous testing and holds multiple industrial certifications, ensuring compliance with international standards.

Image displaying multiple industrial testing certifications including CCC, FCC, CE, and RoHS.
Multiple Industrial Testing Certifications.
Image showing 16 testing procedures for the switch, including high/low temperature, surge, ESD, RS, RE, EFT, CE, CS, PMS, IR/DWV, connector life, topology, network storm, re-start capability at extreme temperature, and shock/vibration testing.
16 Rigorous Testing Procedures.

11.2. Networking Application Solutions

keepLiNK provides solution services for various networking applications, backed by a skilled technical support team.

Image showing two complex networking application diagrams, likely for traffic management and video surveillance systems.
Networking Application Solutions.

© 2023 keepLiNK. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.