1. Introduction
The MESTEK DM100B is a 10000 counts True RMS digital multimeter designed for accurate and reliable electrical measurements. It features auto-ranging capabilities, an LCD backlight, and a portable design, making it suitable for various applications from home use to professional electrical work. This manual provides detailed instructions for the safe and effective use of your DM100B multimeter.
2. Safety Information
WARNING: To avoid possible electric shock, fire, or personal injury, please read all safety information before using the product.
- Always ensure the multimeter is in the correct function and range for the measurement.
- Do not exceed the maximum input values specified for each range.
- Inspect test leads for damage before use. Do not use if insulation is damaged or bare metal is exposed.
- Do not use the multimeter if it appears damaged or if it is not operating properly.
- Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Keep fingers behind the finger guards on the test probes during measurements.
- Replace the battery when the low battery indicator appears to ensure accurate readings.
- The device is rated CAT IV 600V / CAT III 1000V. Adhere to these safety ratings.
3. Package Contents
Verify that all items are present in your package:
- 1 x MESTEK DM100B Digital Multimeter
- 1 x Pair of Test Leads (Red and Black)
- 1 x Temperature Probe (K-type thermocouple)
- 1 x User Manual
- 1 x Packing Box

4. Product Overview
Familiarize yourself with the components and controls of your MESTEK DM100B Digital Multimeter.

The multimeter features a large LCD screen with backlight for clear readings, even in low-light conditions. It also includes a flashlight for illuminating the test area.

5. Setup
5.1 Battery Installation
The MESTEK DM100B requires 2 x 1.5V AA batteries (not included). To install or replace batteries:
- Ensure the multimeter is turned OFF.
- Locate the battery compartment cover on the back of the device.
- Unscrew the retaining screw(s) and remove the cover.
- Insert two 1.5V AA batteries, observing the correct polarity (+ and -).
- Replace the battery compartment cover and secure it with the screw(s).
5.2 Connecting Test Leads
Always connect the test leads correctly for accurate and safe measurements.
- Insert the black test lead into the "COM" (Common) input socket.
- Insert the red test lead into the appropriate input socket based on the measurement function:
- For Voltage (V), Resistance (Ω), Capacitance (mF), Frequency (Hz), Diode, Continuity, Temperature, NCV, and Live measurements, use the "VΩHz" (Positive input socket).
- For Current up to 10A (AC/DC), use the "10A" input socket.
- For Current up to 600mA (AC/DC), use the "mA/uA" input socket.
WARNING: Incorrect test lead insertion can trigger an alarm and lead to inaccurate readings or damage to the device. Always double-check connections.

5.3 Connecting Temperature Probe
For temperature measurements, connect the K-type thermocouple probe to the multimeter.
- Ensure the multimeter is turned OFF.
- Insert the temperature probe's connectors into the "VΩHz" and "COM" input sockets, observing polarity if applicable (usually red to positive, black to negative).
6. Operating Instructions
The MESTEK DM100B features an auto-ranging function, simplifying operation by automatically selecting the appropriate measurement range.
6.1 General Operation
- Power On/Off: Turn the rotary switch from "OFF" to the desired measurement function to power on. Turn back to "OFF" to power off. The multimeter also features automatic shutdown to conserve battery.
- Function Selection: Rotate the central switch to select the primary measurement category (e.g., V~ for AC Voltage, V- for DC Voltage, Ω for Resistance).
- Sub-Function Selection (SEL.V.F.C): For categories with multiple functions (e.g., Diode, Continuity, Capacitance), press the "SEL.V.F.C" button to cycle through them.
- Data Hold (HOLD): Press the "HOLD" button to freeze the current reading on the display. Press again to release.
- Backlight/Flashlight: Press the backlight button (light bulb icon) to turn on/off the display backlight. Press and hold the backlight button to activate the flashlight.
6.2 Measurement Functions
The DM100B supports a wide range of measurements:

6.2.1 AC/DC Voltage Measurement
- Rotate the switch to the V~ (AC Voltage) or V- (DC Voltage) position.
- Connect the test leads in parallel to the circuit or component being measured.
- The display will show the voltage reading. The DM100B features True RMS for accurate AC voltage measurements, even with non-sinusoidal waveforms.


6.2.2 AC/DC Current Measurement
- Rotate the switch to the A~ (AC Current) or A- (DC Current) position.
- Connect the multimeter in series with the circuit. Ensure the red lead is in the 10A or mA/uA socket as appropriate.
- The display will show the current reading.
6.2.3 Resistance Measurement (Ω)
- Rotate the switch to the Ω position.
- Connect the test leads across the component to measure its resistance. Ensure the component is de-energized.
- The display will show the resistance reading.

6.2.4 Capacitance Measurement (mF)
- Rotate the switch to the Capacitance position (often shared with Diode/Continuity, use SEL button).
- Discharge the capacitor before connecting the test leads.
- Connect the test leads across the capacitor.
- The display will show the capacitance reading.

6.2.5 Frequency Measurement (Hz)
- Rotate the switch to the Frequency position (often shared with Voltage, indicated by Hz).
- Connect the test leads to the circuit where frequency needs to be measured.
- The display will show the frequency reading.
6.2.6 Temperature Measurement
- Rotate the switch to the TEMP position.
- Connect the K-type thermocouple to the input sockets.
- Place the tip of the thermocouple on or near the object whose temperature is to be measured.
- The display will show the temperature in Celsius or Fahrenheit.

6.2.7 Diode and Continuity Test
- Rotate the switch to the Diode/Continuity position (use SEL button to switch).
- For Diode Test: Connect the red lead to the anode and black lead to the cathode. The forward voltage drop will be displayed. Reverse the leads to check for open circuit.
- For Continuity Test: Connect the test leads across the circuit. A continuous beep indicates continuity (low resistance).
6.2.8 Non-Contact Voltage (NCV) Detection
- Rotate the switch to the NCV position.
- Move the top part of the multimeter near a live wire or electrical outlet.
- The device will emit an alarm sound and the non-contact voltage indicating light will illuminate if AC voltage is detected, ensuring user safety.

6.2.9 Live Wire Detection
- Rotate the switch to the Live position.
- Use the red test lead to touch the wire or terminal.
- The multimeter will indicate if the wire is live.
7. Maintenance
7.1 Cleaning
To clean the multimeter, wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is powered off and test leads are disconnected before cleaning.
7.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries as described in Section 5.1.
7.3 Fuse Replacement
The DM100B is equipped with a double fuse for overload protection. If the current measurement function stops working, the fuse may need replacement. Refer to the technical specifications for fuse ratings. Fuse replacement should only be performed by qualified personnel.

8. Troubleshooting
- No Display/Low Battery: Check battery installation and replace batteries if necessary.
- "OL" (Overload) Display: The measured value exceeds the selected range. For auto-ranging, this indicates the value is beyond the meter's maximum capability for that function. Ensure the correct function and input jacks are used.
- "LEAD" Error Message: Indicates incorrect insertion of test leads for the selected function. Refer to Section 5.2 for correct lead connection.
- Inaccurate Readings: Ensure test leads are properly connected, batteries are fresh, and the correct measurement function is selected. Environmental factors (temperature, humidity) can also affect accuracy.
9. Specifications
The following table details the technical specifications of the MESTEK DM100B Digital Multimeter:

| Parameter | Specification |
|---|---|
| Model | DM-100B |
| DC Voltage | 0-1000V |
| AC Voltage | 0-750V |
| DC Current | 0-10A |
| AC Current | 0-10A |
| Resistance | 0-10MΩ |
| Capacitance | 0-6mF |
| Frequency | 50-1000Hz |
| Temperature | -20℃-1000℃ (-4°F-1832°F) |
| On/Off Beep | Support |
| Range Gear | Auto Range |
| Display Count | 10000 COUNTS |
| Automatic Shutdown | Support |
| NCV | Support |
| Wrong Insertion Alarm | Support |
| Data Retention | Have |
| Flashlight Light | Have |
| Undervoltage Prompt | Support |
| Battery | 2*1.5V AA battery (not included) |
| Screen | LCD screen |
| Safety Level | CAT IV 600V / CAT III 1000V |
| Input Resistance Against | 10MΩ |
| Dimensions | 185*85*40mm |
| Weight | About 500g |
| DIY Supplies | Electrical |
| Operating Temperature | 0 - 40 ℃ |
| Certification | CE |
| Origin | Mainland China |
10. User Tips
- Calibration: While the DM100B is factory calibrated, if you suspect inaccuracies, consult the manufacturer's support for calibration procedures. Regular calibration is not typically required for general use.
- True RMS Advantage: The True RMS feature provides more accurate readings for AC signals that are not pure sine waves, which are common in modern electronics.
- Battery Life: To maximize battery life, always turn the multimeter off when not in use. The automatic shutdown feature helps, but manual power-off is best for extended storage.
- Probe Storage: Store test leads and temperature probes neatly to prevent damage to the wires and connectors.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the MESTEK customer service or the retailer from whom you purchased the product. Keep your purchase receipt as proof of purchase.