KKMOON FY6900

Contents

FY6900 Series DDS Function/Arbitrary Waveform Generator Instruction Manual

Model: FY6900

Product Overview

The FY6900 series is a high-performance DDS (Direct Digital Synthesizer) function/arbitrary waveform generator capable of producing stable, precise, pure, and low-distortion signals. It features a 2.4-inch TFT color LCD for simultaneous display of parameters and graphics for both channels. Utilizing MagicPulse Technology, it achieves low jitter (RMS) of less than 200ps, making it suitable for various electronic testing and development applications. This dual-channel device supports a wide range of waveform outputs, modulation types, sweep functions, and voltage control output (VCO).

FY6900 Function Signal Generator front view
Front view of the FY6900 DDS Function/Arbitrary Waveform Generator.

Key Features

  • Direct Digital Synthesizer (DDS) technology for stable and precise signals.
  • 2.4-inch TFT color LCD (320x240 resolution) displaying CH1 and CH2 parameters and graphics.
  • MagicPulse Technology for low jitter (RMS < 200ps).
  • 14-bit high-speed D/A converter, 250MSa/s (20M, 60M) or 300MSa/s (100M) sample rate.
  • Outputs up to 99 groups of functions/arbitrary waveforms, including 35 preset and 64 user-defined.
  • Preset waveforms: Sine, Square (adjustable Duty Cycle), Pulse (adjustable width/cycle), Triangle/Ramp, CMOS (0-12V), Four channels TTL, Exponential Rise/Fall, Noise, DC.
  • Stores 64 arbitrary waveform data files (8192 points * 14bits each).
  • Various modulation types: AM, FM, PM, ASK, FSK, PSK.
  • Sweep Function: Sweeps frequency, amplitude, offset, and duty cycle with Linear/Logarithm types.
  • VCO Function (Voltage Control Output) for external signal control of frequency, amplitude, offset, duty cycle, and PWM.
  • Burst Output Function with Manual, internal CH2, and External Trigger options (1-1048575 pulse trains).
  • Counter Function with DC and AC coupling modes.
  • Standard dual full functional channels, equivalent to two independent generators.
  • Channel SYNC Function for waveform and state copy between channels.
  • Supports multi-channel synchronous output (up to 16 channels) with adjustable phase (0.01° precision).
  • Amplitude resolution up to 1mV, range 1mV-24Vpp (20M, 60M) or 1mV-25Vpp (100M).
  • Independent duty cycle adjustment per channel (0.01%-99.99%, 0.01% resolution).
  • -12V to +12V DC Offset function (0.001V resolution).
  • Save Function for 20 sets of user-set parameters.
  • PC communication function with open protocol for secondary development.
  • Output Short-circuit Protection (60+ seconds under short-circuit).
  • Includes powerful waveform editing PC software.
  • Durable ABS plastic shell with table-type design, 100-240V (AC) wide range voltage power supply.

Package Contents

  • 1 x DDS Signal Generator (FY6900 model)
  • 1 x Power Cable
  • 1 x USB Data Cable
  • 1 x BNC-BNC Cable
  • 2 x BNC-Clip Cables

Setup

Front Panel Overview

Front Panel Diagram of FY6900
Diagram of the FY6900 Front Panel controls and connectors: Power Button, 2.4 inch TFT Color LCD, Function Shortcut Buttons (WAVE, MOD, SWEEP, COUNTER, VCO, SYSTEM), Knob, Direction Button, Menu Button, Output Terminal (CH1 Output1, CH2 Output2), Input Terminal (Counter).

Back Panel Overview

Back Panel Diagram of FY6900
Diagram of the FY6900 Back Panel connectors: USB Communication Interface, Power Switch, AC Power Input, 4 Channel TTL Output, Special Function Port.

Initial Connection

  1. Connect the provided power cable to the AC Power Input on the back panel and then to a suitable AC power outlet (100-240V).
  2. Connect the USB Data Cable to the USB Communication Interface on the back panel and to your PC for software control, if desired.
  3. For signal output, use the BNC-BNC cable or BNC-Clip cables to connect the CH1 Output1 or CH2 Output2 terminals to your testing equipment (e.g., oscilloscope).
  4. For counter functions, connect the signal source to the Input Terminal (Counter) using a BNC cable.
  5. Ensure all connections are secure before powering on the device.

Operating Instructions

Power On/Off

  • To power on, press the Power Button on the front panel after connecting the AC power.
  • To power off, press the Power Button again.

Basic Waveform Generation

  1. Press the WAVE shortcut button to select the desired waveform type (e.g., Sine, Square, Triangle).
  2. Use the Knob and Direction Buttons to navigate and adjust parameters such as frequency, amplitude, and offset.
  3. The 2.4-inch TFT color LCD will display the waveform parameters and a graphical representation of the output.
FY6900 displaying a square wave on an oscilloscope
The FY6900 generating a square wave, observed on an oscilloscope.

Adjusting Frequency and Duty Cycle

The video demonstrates adjusting the output waveform to rectangular, then freely adjusting the output frequency and duty cycle. The MagicPulse technology ensures low jitter even with these adjustments.

Demonstration of adjusting waveform type, frequency, and duty cycle on the FY6900, showing low jitter output.
Close-up of FY6900 display showing Trapezoid waveform parameters
Close-up view of the FY6900 display showing detailed parameters for a Trapezoid waveform, including frequency, amplitude, offset, and fall time.

Modulation Functions

  • Press the MOD shortcut button to access modulation settings.
  • Select from AM, FM, PM, ASK, FSK, and PSK modulation types.
  • Adjust modulation parameters using the Knob and Direction Buttons.

Sweep Function

  • Press the SWEEP shortcut button to configure sweep parameters.
  • The device can sweep frequency, amplitude, offset, and duty cycle.
  • Choose between Linear and Logarithm sweep types and set the sweep time (0.01S to 999.99S).
  • Select sweep directions: Up, Down, or Roundtrip.

Counter Function

  • Press the COUNTER shortcut button to activate the counter.
  • Connect the signal to be measured to the Input Terminal (Counter).
  • Select DC coupling or AC coupling mode as appropriate for your measurement.

User Tips

  • When working with modulation, ensure you select the correct AM/FM/PM mode for your application. The device supports various modulation types for flexible signal generation.
  • For precise pulse generation, utilize the accurate pulse width and cycle time settings available for the Pulse waveform.
  • Take advantage of the 64 user-defined waveform storage slots to save frequently used or custom waveforms for quick recall.
  • When connecting to a PC, use the provided waveform editing software to create complex arbitrary waveforms and upload them to the generator.

Specifications

FeatureSpecification
Model NumberFY6900 20/60/100MHz Function Signal Generator
Sine Frequency Range0~20MHz (20M), 0~60MHz (60M), 0~100MHz (100M)
Sampling Rate250MSa/s (20M, 60M), 300MSa/s (100M)
Output Amplitude Range1mV~24Vpp (20M, 60M), 1mV~25Vpp (100M)
Vertical Resolution14 bits
Waveform Length8192 points * 14bits
Minimum Pulse Width20ns
Modulation TypesAM, FM, PM, ASK, FSK, PSK
Display2.4 inch (320*240), TFT color display
Non-Volatile Storage64 user-defined arbitrary waveforms, (8K 14bits) * 64
Power SupplyAC100V~240V
Item Size (L*W*H)210 * 195 * 75mm / 8.27 * 7.68 * 2.96in
Item Weight611g / 21.56oz
Battery IncludedNo
DIY SuppliesElectrical
OriginMainland China
CertificationNone
Display Size3.0 - 4.9 Inches

Maintenance

To ensure the longevity and optimal performance of your FY6900 Function Signal Generator, follow these general maintenance guidelines:

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning the exterior.
  • Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
  • Do not block the ventilation openings on the device, especially on the back panel, to prevent overheating.
  • Store the device in a safe, dry place when not in use.
  • Ensure all cables are properly connected and not under strain.
  • The device features output short-circuit protection, allowing channels to work for over 60 seconds under short-circuit conditions. However, prolonged short-circuits should be avoided.

Troubleshooting

This section provides basic troubleshooting steps for common issues. For more complex problems, please contact customer support.

  • No Power:
    • Check if the power cable is securely connected to both the device and the power outlet.
    • Ensure the power switch on the back panel is in the 'ON' position.
    • Verify that the power outlet is functional.
  • No Signal Output:
    • Confirm that the output cables (BNC-BNC or BNC-Clip) are correctly connected to the CH1/CH2 Output terminals and to your receiving equipment.
    • Check the settings on the device's display to ensure a waveform is selected and its amplitude/frequency are set to appropriate values.
    • Verify that the receiving equipment (e.g., oscilloscope) is properly configured to display the signal.
  • Incorrect Waveform/Parameters:
    • Double-check the waveform type, frequency, amplitude, offset, and duty cycle settings on the device's display.
    • If using PC software, ensure the correct parameters are sent to the device.
  • Device Not Responding to Controls:
    • Try restarting the device by powering it off and on again.
    • If connected to a PC, ensure the communication software is running correctly and the USB connection is stable.

Warranty and Support

This product comes with a 1-year guarantee. If your purchase does not meet merchantable quality, fitness for purpose, or match the description, issues will be resolved.

For any questions or support needs, please contact:


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.