HoldPeak HP-38A

HoldPeak HP-38A LCD Electronic Current Voltage Tester

Instruction Manual

1. Introduction

The HoldPeak HP-38A is a versatile LCD electronic current and voltage tester designed for clear readings and ease of use. It features a compact design, top lighting for visibility, and automatic power-off to conserve battery life. This device is suitable for measuring AC/DC current and voltage, performing continuity tests, and phase rotation tests with high accuracy and safety.

Package Contents

  • 1 x HoldPeak HP-38A Voltage Tester
  • 1 x English User Manual

Unboxing and Initial Inspection:

Video: Unboxing and initial inspection of the HoldPeak HP-38A Voltage Tester, showing the device and included manual.

2. Device Overview

Familiarize yourself with the components and controls of your HP-38A Voltage Tester:

Diagram of HoldPeak HP-38A with labeled parts: Lamp light, Test lead fixture, LCD display, Protective casing, SELECT key, Battery cover, COM input test lead.

Image: Labeled components of the HP-38A Voltage Tester.

Diagram of HoldPeak HP-38A showing button functions: Probe cover, LED light, Test Leads, Battery compartments.

Image: Overview of button functions and accessories.

Key Components:

  • Lamp Light: Provides illumination for working in dark environments.
  • Test Lead Fixture: Secures the test leads.
  • LCD Display: Shows measurement readings.
  • Protective Casing: Durable outer shell for protection.
  • SELECT Key: Used to choose between resistance, diode, continuity, and capacitance tests, or to switch between DC and AC voltage ranges.
  • Battery Cover: Located at the bottom for battery access.
  • COM Input Test Lead: Common input for measurements.

3. Setup

Battery Installation

The HP-38A requires two 1.5V (IEC LR03) batteries. Follow these steps to install or replace them:

  1. Locate the battery cover at the bottom of the device.
  2. Twist the battery cover counter-clockwise to unlock and remove it.
  3. Insert two 1.5V (IEC LR03) batteries, ensuring correct polarity (+ and -).
  4. Replace the battery cover and twist it clockwise to secure.

Battery Installation Demonstration:

Video: Demonstration of installing batteries into the HP-38A.

Probe Cover Management

For safety and to protect the probe tips, the device comes with protective probe covers. Remove them before use and replace them after completing your measurements.

Probe Cover Demonstration:

Video: Demonstration of removing and replacing probe covers.

4. Operating Instructions

Voltage Test (AC/DC)

To measure voltage:

  1. Ensure the probes are securely connected to the device.
  2. Connect both probes to the object under test.
  3. The voltage reading will be displayed on the LCD, and corresponding LEDs will light up to indicate the voltage level and polarity (AC, +DC, -DC).
  4. A high voltage indicator (LED) will light up if the measured voltage exceeds 50V.
  5. The auto-hold function will lock the present display value when the L1 and L2 probes disconnect from the measured terminal.
Diagram showing LED voltage indications for 12/24/50/120/230/400/690V, polarity, LCD, continuity/live circuit LED, L/R LEDs for phase rotation, power LED, and high voltage indication.

Image: Detailed LED indications for voltage and other functions.

Voltage Test Demonstration:

Video: Demonstration of voltage testing, including polarity indication and auto-hold function.

Continuity Test

To perform a continuity test:

  1. Press the SELECT key to enter continuity test mode.
  2. Connect the probes across the circuit or component you wish to test.
  3. If the on-resistance of the measured object is within the range of 0-550kΩ (±200K), the RXΩ LED indicator will light up and a buzzer will sound.
  4. In continuity mode, the instrument operates similarly to a self-diagnostic test.

Continuity Test Demonstration:

Video: Demonstration of the continuity test function.

Phase Rotation Test

For three-phase 4-wire AC systems (50Hz-60Hz):

  1. Connect two probes to the tested object (e.g., phase lines).
  2. Observe the L and R LEDs:
    • If the R LED is on, the L2 test probe is connected to phase B line and the L1 test probe is connected to phase A line.
    • If the L LED is on, the L2 test probe is connected to phase A line and the L1 test probe is connected to phase B line.
  3. The phase voltage will be indicated by the LEDs, and the value displayed on the LCD screen.

Phase Rotation Test Demonstration:

Video: Demonstration of the phase rotation test.

Pen Light Function

Press the 'PEN' button to activate the built-in LED flashlight. This is useful for illuminating work areas in dim or dark environments.

Image showing the LED flashlight of the HP-38A illuminating a dark area.

Image: The HP-38A's LED flashlight in use.

5. Maintenance

Cleaning

To clean the device, wipe it with a dry, soft cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the casing or internal components.

Storage

Store the HP-38A in a dry, cool place, away from direct sunlight and extreme temperatures. If the device will not be used for an extended period, remove the batteries to prevent leakage and damage.

Battery Replacement

The device features a low battery indication. When the battery voltage is lower than 2.4±0.1V, the power indicator will blink or turn off, signaling that the batteries need to be replaced. Refer to the 'Battery Installation' section for detailed steps.

Image showing the HP-38A with a low battery indication, where the power indicator blinks or turns off.

Image: Low battery indication on the HP-38A.

6. Troubleshooting

  • No Display/Power:
    Check if the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
  • Inaccurate Readings:
    Ensure the probes are clean and making good contact with the test points. Verify that the correct measurement mode is selected using the SELECT key.
  • No Continuity Beep:
    Confirm that the resistance of the circuit or component being tested is within the specified range of 0-550kΩ.
  • LEDs Not Lighting Up:
    Check the battery level. Ensure the voltage being measured is within the device's operational range for LED indication.

7. Specifications

FeatureSpecification
Model NumberHP-38A
Brand NameHoldPeak
Display TypeDigital Only
Dimensions251*77*28mm
Weight300g
Power SupplyBattery (2x 1.5V IEC LR03)
Battery IncludedNo
Operating Temperature-10~55℃
Storage Temperature-20~60℃
HumidityMax 85% RH (No condensation)
AltitudeUp to 2000m
Accuracy Class±(3%+3)
LCD Voltage Range12-690V AC/DC
Resolution (LCD)1V
LED Voltage Range12-690V AC/DC
Nominal Voltage (Europe)12/24/50/120/230/400/690V
High Voltage Indication Range50-690V AC/DC
Phase Rotation Test SystemThree-phase 4-wire system AC
Phase Rotation Test Frequency50Hz~60Hz
Phase Range120±5 degree
Continuity Test Detection Range0-550KΩ (±200K)
Continuity Test CurrentApprox. 1.5uA
Internal Battery Consumption (Test)Approx 33mA (Battery 3V, measuring 690V AC)
IP RatingIP64
CertificationNone (Complies with EN 61243-3/IEC 61243-3, EN 6101-1/IEC 6101-1, CAT III 690V/CAT IV 600V, ETL: UL 6101-1)
Pollution Degree2
Low Battery IndicationYES
Auto Power OffYES
Pen LightYES

8. Warranty and Support

This product comes with a 1-year warranty from the date of purchase. For technical support, warranty claims, or any questions regarding the operation of your HoldPeak HP-38A, please contact the seller or manufacturer directly through their official channels.

9. User Tips

  • Always ensure probes are fully inserted and making good contact for accurate and reliable readings.
  • Check the battery level before critical measurements, especially when working in low-light conditions where the pen light might be needed.
  • Utilize the auto-hold function for convenience when taking readings in hard-to-reach areas, as it locks the display value after disconnection.
  • For safety, always replace the protective probe covers after use.

10. Frequently Asked Questions (FAQ)

Q: Does this device require batteries?
A: Yes, the HoldPeak HP-38A requires two 1.5V (IEC LR03) batteries for operation.
Q: How do I know when to replace the batteries?
A: The power indicator will blink or turn off when the battery voltage drops below 2.4±0.1V, signaling that it's time for replacement.
Q: Can I use this device in dark environments?
A: Yes, the HP-38A features a built-in LED pen light that can be activated by pressing the 'PEN' button, providing illumination for your work area.
Q: What is the IP rating of this device?
A: The device has an IP64 rating, which means it is protected against dust ingress and splashing water from any direction.

Related Documents - HP-38A

Preview HOLDPEAK 770HC Digital Multimeter Operator's Manual
Operator's manual for the HOLDPEAK 770HC Digital Multimeter, detailing its features, specifications, operating instructions, safety precautions, and maintenance.
Preview HoldPeak HP-770HC-APP Digital Multimeter User Manual
Comprehensive user manual for the HoldPeak HP-770HC-APP digital multimeter, detailing its features, specifications, operating instructions, safety precautions, and mobile app connectivity.
Preview HoldPeak HP-981A Инфракрасный термометр: Инструкция по эксплуатации и технические характеристики
Полное руководство пользователя для инфракрасного термометра HoldPeak HP-981A, включая обзор, инструкции по эксплуатации, меры предосторожности, техническое обслуживание и спецификации. Узнайте, как безопасно и точно измерять температуру бесконтактным способом.
Preview HoldPeak HP-6000WM-APP Anemometer User Manual and App Guide
Comprehensive user manual for the HoldPeak HP-6000WM-APP Anemometer, covering features, operation, technical specifications, and the companion Intelligent Meter mobile application for device management and data logging.
Preview HoldPeak 866B Digital Anemometer Instruction Manual
Comprehensive instruction manual for the HoldPeak 866B Digital Anemometer, detailing its functions, operation, specifications, and safety guidelines for measuring wind speed and temperature.
Preview HoldPeak Handheld Laser Distance Meter User Manual - Models 5040B, 5060B, 5080B, 5100B
User manual for HoldPeak handheld laser distance meters (models 5040B, 5060B, 5080B, 5100B), covering features, operation, technical specifications, and maintenance.