1. Introduction
This manual provides detailed instructions for the safe and effective use of your KKMoon KKM99 or KKM100 intelligent pen-type digital multimeter. This device is designed for automatic identification and measurement of various electrical parameters without the need for manual function selection, offering stable performance, high precision, and reliability. It features a clear display and overload protection.
The KKM99 model features a positive display screen, while the KKM100 model includes a color screen and an additional phase sequence measurement function.

2. Safety Information
Always observe basic safety precautions when using this multimeter to reduce the risk of fire, electric shock, or personal injury.
- Do not exceed the maximum voltage ratings specified for the device.
- Ensure the test leads are in good condition, without any damage to the insulation.
- Do not use the multimeter if it appears damaged or is not operating properly.
- Always disconnect power to the circuit before measuring resistance, capacitance, or continuity.
- Be cautious when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
- Keep fingers behind the finger guards on the test probes during measurements.
- Replace the battery when the low battery indicator appears to ensure accurate readings.
- Do not attempt to repair or modify the multimeter. Refer servicing to qualified personnel.
3. Product Overview
The KKMoon pen-type multimeter is a compact and portable tool designed for ease of use. It integrates multiple measurement functions into a single, ergonomic design.
3.1 Components
- Pen-type Body: Main housing for the display, buttons, and internal circuitry.
- Test Probe: Integrated probe for direct measurements.
- Test Lead Jack: Port for connecting the external test lead.
- External Test Lead: For two-point measurements.
- Display Screen: Digital display for readings (positive display for KKM99, color screen for KKM100).
- Function Buttons: 'Select', 'HOLD', 'N/L/P' buttons for mode selection and special functions.
- Pen Clip: For convenient carrying.
- Battery Compartment: Located at the rear for AAA battery installation.



4. Setup
4.1 Battery Installation
The multimeter requires one AAA battery (not included) for operation.
- Locate the battery compartment cover on the back of the multimeter.
- Use a suitable tool (e.g., a small screwdriver or the provided plastic tool if available) to open the battery compartment.
- Insert one AAA battery, ensuring correct polarity (+ and -).
- Close the battery compartment cover securely.

4.2 Connecting Test Leads
For measurements requiring two points, connect the provided external test lead to the jack at the bottom of the multimeter.
5. Operating Modes
The multimeter features intelligent automatic identification for common measurements and manual selection for specialized functions.
5.1 Automatic Identification Mode
When powered on, the multimeter automatically detects and measures:
- DC Voltage: Connect the test probes across the DC voltage source.
- AC Voltage: Connect the test probes across the AC voltage source.
- Resistance: Connect the test probes across the component to measure resistance.



5.2 Manual Selection Modes
Press the 'Select' button to cycle through additional measurement functions:
- Capacitance: Measure the capacitance of capacitors.
- Diode Test: Test diodes for forward voltage drop.
- Continuity Test (Buzzer): Check for continuity with an audible alert.
- Frequency: Measure the frequency of AC signals.
- Temperature: Measure ambient temperature in Celsius or Fahrenheit.


5.3 Special Functions
- Non-Contact Voltage (NCV): Detect AC voltage without direct contact.
- Live Wire Detection (N/L/P button): Identify live and null wires in an electrical outlet. The multimeter will provide an audio and light alarm for live wires.
- Breakpoint Lookup: Detect breaks in electrical wires with sound and light alarms.
- Phase Sequence Detection (KKM100 only): Determine the phase sequence (corotation, reversal, or out of phase) in three-phase systems.
- Data Hold (HOLD button): Freeze the current reading on the display.
- Flashlight: Long press the 'N/L/P' button to activate the built-in flashlight.
- Automatic Shutdown: The multimeter will automatically power off after 5 minutes of inactivity to conserve battery life.



6. Specifications
| Parameter | Specification |
|---|---|
| Model | KKM99 / KKM100 |
| Material | ABS |
| Color | Black |
| Power | 1 * AAA battery (not included) |
| DC Voltage Range | 0.8V ~ 1000V |
| AC Voltage Range | 0.8V ~ 700V |
| Resistance Range | 0.1Ω ~ 60MΩ |
| Capacitance Range | 10nF ~ 60mF |
| Frequency Range | 1Hz ~ 10MHz |
| Temperature Range | -20℃ ~ 50℃ (0℉ ~ 122℉) |
| Diode Test Voltage | 3.0V |
| Buzzer Threshold | 0.5Ω ~ 5Ω |
| Display Type | Digital Display |
| Operating Temperature | Other (General ambient conditions) |
| Package Dimensions | 171 * 21 * 21mm / 6.7 * 0.8 * 0.8in |
| Package Weight | 80g / 2.8ounce |
| Origin | Mainland China |
| Certification | NONE |
| DIY Supplies | Electrical |
7. Maintenance
Proper maintenance ensures the longevity and accuracy of your multimeter.
- Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
- Battery Replacement: Replace the AAA battery promptly when the low battery indicator appears on the display. Refer to Section 4.1 for battery installation instructions.
- Storage: Store the multimeter in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery to prevent leakage.
- Test Leads: Regularly inspect test leads for any signs of damage, such as cracked insulation or exposed wiring. Replace damaged leads immediately.
8. Troubleshooting
If you encounter issues with your multimeter, refer to the following common problems and solutions:
- No Display / Device Not Turning On:
- Check if the battery is installed correctly with the right polarity.
- Replace the AAA battery with a fresh one. - Inaccurate Readings:
- Ensure the battery is not low. Replace if necessary.
- Verify that the test leads are properly connected and undamaged.
- Make sure the probes are making good contact with the circuit points. - Automatic Shutdown During Use:
- This is a normal feature. The multimeter automatically powers off after 5 minutes of inactivity. Press any button to reactivate it. - No Response in Live Wire / Breakpoint Lookup:
- Ensure the device is held correctly and the sensor area is clear.
- Confirm the function is correctly selected (if applicable).
If the problem persists after attempting these solutions, please contact customer support.
9. User Tips
- Portability: The compact, pen-type design makes it easy to carry in a pocket or tool belt, ideal for on-the-go measurements.
- Non-Contact Measurement: Utilize the NCV function for quick and safe detection of AC voltage without needing to touch live conductors.
- Automatic Mode: For basic voltage and resistance checks, rely on the intelligent automatic identification mode to save time and simplify operation.
- KKM100 Phase Sequence: If you have the KKM100 model, make use of the phase sequence detection for quick verification in three-phase electrical systems.
10. Warranty and Support
This product typically comes with a one-year warranty from the date of purchase. The warranty covers manufacturing defects but generally excludes damage caused by misuse, unauthorized disassembly, or accidental damage.
If the product is damaged during transit, please contact the seller immediately upon receipt before attempting any repairs or leaving feedback. We are committed to resolving any issues to your satisfaction.
For technical support, warranty claims, or any other inquiries, please contact your retailer or the manufacturer's customer service department. Please have your product model and purchase details ready.