1. Product Introduction
This device is an intelligent balancing protection board designed specifically for 10S/12S/13S/14S/16S series lithium batteries, supporting ternary lithium/lithium iron phosphate batteries. It provides protection against overcharging, over-discharging, over-current, over-temperature, and short circuits. It also features balanced charging to maintain battery health and extend service life. It is suitable for series-connected lithium battery packs, balancing individual cell voltages when they reach the equilibrium turn-on voltage.

2. Product Model Selection and Description
The HT-916L series supports 9 to 16 strings. The model name indicates the battery type, number of strings, and discharge current. For example:
- HT-916 LOS 12S 160A: LOS indicates NCM (Nickel Cobalt Manganese) battery, 12S for 12 strings, 160A for discharge current.
- HT-916 LPS 12S 160A: LPS indicates LFP (Lithium Iron Phosphate) battery, 12S for 12 strings, 160A for discharge current.
Customization for 9-16S series is supported based on specific requirements.
3. Specifications
The length and width of the 9-16S series protection board are consistent, with thickness varying by current rating.
3.1. General Dimensions
| Current | 80A | 120A | 160A |
|---|---|---|---|
| Thickness (MM) | 9 | 12 | 12 |
Note: Length and width are generally 115mm x 66mm for these models.
3.2. Lithium Iron Phosphate (LFP) Parameters (Room Temperature 25°C)
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Serial number | S | Number of battery strings | 9-16S |
| Amperage | A | Current that the shield can withstand | 80A/120A/160A |
| Battery type | Ternary lithium / lithium iron phosphate | Lithium iron phosphate | |
| Overcharge protection | VDET1 | Overcharge detection voltage | 3.65V±0.035V |
| TVDET1 | Overcharge detection delay time | 1.3s (MAX) | |
| VREL1 | Overcharge relieve voltage | 3.55V±0.025V | |
| Overdrive protection | VDET2 | Over discharge test voltage | 2.350V±0.025V |
| tVDET2 | Delay time for over discharge detection | 1.5s (MAX) | |
| VREL2 | Over discharge relieve voltage | 2.55V±0.025V relieve | |
| Overcurrent discharge | VDET3 | Discharge overcurrent detection voltage | 21mV±5mV |
| IDP | Theoretical instantaneous single pulse current (MOSFET temp 20-45°C) | 350/450/650A | |
| Short-circuit protection | TSHORT | Detect latency | 300US (MAX) |
| Protection conditions | External load circuit short circuit | ||
| Protection release conditions | Disconnect the short-circuit circuit | ||
| Internal resistance | RDS | Main circuit on state resistance (battery voltage=3.4V) | B- to P- RDS≤0.2mΩ |
| Consume current | IDD | Internal consumption of the circuit during operation | MIN: 0.3μΑ ΜΑΧ: 100μΑ |
| Power balance | VBU | Electricity balance detection voltage | 3.45V±0.035V |
| tVBU | Balance startup delay time | 1.6S (MAX) | |
| VBL | Power balance release voltage | 3.44V±0.035V | |
| IB | 3.45V battery balance current | 67mA±5mA | |
| Overtemperature protection | Charging optional | Low temperature -0 °C± 5 °C | no |
Note: The overcurrent value and internal resistance are dynamic parameters. Each battery cell voltage needs to be ≥ 3.25 V during testing.
3.3. Ternary Lithium Parameters (Room Temperature 25°C)
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Serial number | S | Number of battery strings | 9-16S |
| Amperage | A | Current that the shield can withstand | 80A/120A/160A |
| Battery type | Ternary lithium / lithium iron phosphate | Ternary lithium | |
| Overcharge protection | VDET1 | Overcharge detection voltage | 4.25V±0.035V |
| tVDET1 | Overcharge detection delay time | 1.3s (MAX) | |
| VREL1 | Overcharge relieve voltage | 4.19V±0.025V | |
| Overdrive protection | VDET2 | Over discharge test voltage | 2.80V±0.025V |
| tVDET2 | Delay time for over discharge detection | 1.5s (MAX) | |
| VREL2 | Over discharge relieve voltage | 3.0V±0.025V relieve | |
| Overcurrent discharge | VDET3 | Discharge overcurrent detection voltage | 21mV±5mV |
Note: The overcurrent value and internal resistance are dynamic parameters. Each battery cell voltage needs to be ≥ 3.6 V during testing.
3.4. Continuous Working Current and Charger Selection
| Parameter | Description | Standard |
|---|---|---|
| Most continuous large working current (Charge) | Rated current of charger when charging battery pack | 80A/120A/160A (Equivalent to A of the protective board) |
| Most continuous large working current (Discharge) | Rated current of battery pack when discharging the load | 80A/120A/160A (Equivalent to A of the protective board) |
| Charger selection | Voltage (Number of strings × 3.65 ± 0.05V for LFP, 4.2 ± 0.05V for Ternary) | ≤ 80A/120A/160A (Equivalent to A of the protective board) |
| Charging MOS highest voltage withstand | Highest voltage value charging port can withstand when connected to charger | Serial number * 3.65V (LFP), Serial number * 4.2V (Ternary) |
3.5. Specific Model Parameters
- 16S 60A 80A 120A 160A 3.7V Same Port
- Size: 116×50×12mm
- Overcharge protection: 4.25v±0.25v
- Charging recovery: 4.2V
- Over-discharge protection: 2.8v±0.25v
- Discharge recovery: 3.0v
- Max continuous current: 60A/80A/120A/160A
- Max Charge Current: 30A/40A/60A/80A
- Peak Current: 240A/360A/480A
- Balance current: 100 mA
- Balanced starting voltage: 4.22v±0.25v
- 16S 80A 120A 160A 3.2V Same Port
- Size: 115×66×18mm
- Overcharge protection voltage: 3.65V
- Charge protection release voltage: 3.55V
- Over-discharge protection voltage: 2.35V
- Discharge release voltage: 2.55V
- Balance start Voltage: 3.4V
- Abnormal high voltage protection: yes
- Temperature protection: Optional
- Maximal continuous current: 60A/80A/120A/160A
- Peak current: 180A/240A/360A/480A
- Balanced current: 100Ma
- 16S 200A 350A 3.7V Same Port
- Size: 190*97*14mm
- Overcharge protection: 4.25v±0.25v
- Charging recovery: 4.2V
- Over-discharge protection: 2.8v±0.25v
- Discharge recovery: 3.0v
- Max continuous current: 160A
- Max Charge Current: 200A/350A
- Peak Current: 600A/1050A
- Balance current: 100 mA
- Balanced starting voltage: 4.22v±0.25v
- 16S 200A 350A 3.2V Same Port
- Size: 190*97*14mm
- Overcharge protection voltage: 3.65V
- Charge protection release voltage: 3.55V
- Over-discharge protection voltage: 2.35V
- Discharge release voltage: 2.55V
- Balance start Voltage: 3.4V
- Abnormal high voltage protection: yes
- Temperature protection: Optional
- Maximal continuous current: 200A/350A
- Peak current: 600A/1050A
- Balanced current: 100Ma
- 16S 250A 3.7V Same Port
- Size: 150*80*14mm
- Overcharge protection: 4.25v±0.25v
- Charging recovery: 4.2V
- Over-discharge protection: 2.8v±0.25v
- Discharge recovery: 3.0v
- Max continuous current: 250A
- Max Charge Current: 750A
- Peak Current: 240A/360A/480A
- Balance current: 100 mA
- Balanced starting voltage: 4.22v±0.25v
- 16S 250A 3.2V Same Port
- Size: 150*80*14mm
- Overcharge protection voltage: 3.65V
- Charge protection release voltage: 3.55V
- Over-discharge protection voltage: 2.35V
- Discharge release voltage: 2.55V
- Balance start Voltage: 3.4V
- Abnormal high voltage protection: yes
- Temperature protection: Optional
- Maximal continuous current: 250A
- Peak current: 750A
- Balanced current: 100Ma
- 16S 150A 3.2V Split Port
- Charging protection voltage: 3.75V
- Discharge protection voltage: 2.2V
- Charge release voltage: 3.55V
- Discharge release voltage: 2.70V
- Balance voltage: 3.50V
- Balance current: 73MA
- Charging current: 60A
- Maximum continuous overcurrent for a long time: 150A
- Instantaneous current limit value: 600A
- Short circuit protection: load short circuit
- Dimensions: 150×80×14MM
- Weight: 200g
- Suitable for: household 48V high-power solar energy storage, matching solar panels within 2000W, continuous load equipment within 5000W
- 16S 250A 3.2V Split Port
- SKU: 1620
- Charging protection voltage: 3.75V
- Discharge protection voltage: 2.2V
- Charge release voltage: 3.55V
- Discharge release voltage: 2.70V
- Balance voltage: 3.50V
- Balance current: 73MA
- Long-term charging current: 100A
- Maximum continuous overcurrent for a long time: 250A
- Instantaneous current limit value: 1100A
- Short circuit protection: load short circuit
- Dimensions: 150×80×14MM
- Weight: 220g
- Suitable for: household 48V high-power solar energy storage, matching solar panels within 3800W, load instant power matching within 9000W, continuous load equipment within 5000W
- 16S 350A 3.2V Split Port
- SKU: 2103
- Charging protection voltage: 3.75V
- Discharge protection voltage: 2.2V
- Charge release voltage: 3.55V
- Discharge release voltage: 2.70V
- Balance voltage: 3.50V
- Balance current: 73MA
- Long-term charging current: 200A
- Maximum continuous overcurrent for a long time: 350A
- Instantaneous current limit value: 1500A
- Short circuit protection: load short circuit
- Dimensions: 209×97×14MM
- Weight: 300g
- Suitable for: household 48V high-power solar energy storage, matching solar panels within 6000W, load instant power matching load equipment within 10KW
4. Setup and Wiring Instructions
Proper wiring is critical for the safe and effective operation of the BMS. Refer to the diagrams below for correct connection procedures.
4.1. General Wiring Diagram

Important Notes for Wiring:
- All holes on both sides of the BMS must be fully connected without any omissions or missing connections.
- When connecting the battery pack, do not use welding to connect the copper sheet interface. Please use the provided screws for connection.
4.2. Product Accessories

The standard package includes:
- Screws: x4
- Nuts: x4
- Collection line (balance wires): x2
Recommended additional accessories for high current connections:


5. Operating Principles and Protection Functions
The BMS intelligently manages your battery pack, providing various protection functions to ensure safety and longevity.
5.1. Protection Functions Overview
| Type | Overcharge single string detection voltage | Overcharge single string release voltage | Overdischarge single string detection voltage | Overdischarge single string release voltage | Single string balanced charging start |
|---|---|---|---|---|---|
| NCM | 4.25V±0.035V | 4.19V±0.025V | 2.8V±0.025V | 3.0V±0.025V | 4.2V±0.035V |
| LFP | 3.65V±0.035V | 3.55V±0.025V | 2.35V±0.025V | 2.55V±0.025V | 3.44V±0.035V |
The BMS continuously monitors individual cell voltages and overall pack conditions to trigger these protections.
6. Troubleshooting
This section provides guidance on common issues and their resolutions.
6.1. Fault Handling Table
| Fault phenomenon | Fault inspection and cause | Processing method |
|---|---|---|
| Can't discharge | First, connect the circuit to activate the protection board for charging, and then measure the voltage of each battery separately. If the voltage of any battery is lower than 3.0V±0.025V (NCM) / 2.35V±0.025V (LFP), the protection board will start over-discharge protection. | If the battery is lower than 3.0V, please charge the battery to 3.7V (NCM) / 3.25V (LFP) and balance it before combining. Do not mix good batteries with poor batteries (if you cannot solve this problem, please contact after-sales service). |
| Can't charge | Measure the voltage of each battery section. If any battery voltage is higher than 4.215V (NCM) / 3.615V (LFP) or so, the protection board will start overcharge protection. | If the battery is higher than 4.215V (NCM) / 3.615V (LFP), please discharge the battery to about 3.7V until it is balanced before combining. Do not mix good batteries with poor batteries (if you cannot solve this problem, please contact after-sales). |
| Charging/discharge failure | B-, B1, B2, B3, ..., B+ Wrong wiring | Redraw the wiring or operate under the guidance of customer service. |
| Overcharge/discharge protection is invalid | B-, B1, B2, B3, ..., B+ Wrong wiring | Redraw the wiring or operate under the guidance of customer service. |
| Discharge protection | Check whether the current value of the load starting power supply exceeds the overcurrent protection current of the protection board. | Replace the protection board with a larger current (if not solved, please contact after-sales). |
| Component is welded loosely | One of the components has a pin that is not connected to the PCB pad. | You can repair the welding by yourself (if it still cannot be solved, please contact after-sales). |
| Component welding | There is a short circuit between two or more pins of the element. | Remove the component and re-weld (if not, please contact after-sales). |
| Electrostatic breakdown | When the MOS tube is not powered, the forward and reverse resistance of any two pins of the G, D and S terminals are 0. | You can remove and replace the MOS tube by yourself (if it still cannot be solved, please contact after-sales). |
Our company guarantees that each product is shipped after being tested by professional protection board testing instruments. However, the combination battery of the protection board may be damaged by static electricity and current, and it is normal to have defective products in use.
7. Maintenance
To ensure the longevity and optimal performance of your Heltec BMS, follow these maintenance guidelines:
- Regularly inspect all wiring connections for tightness and corrosion. Loose connections can lead to poor performance or damage.
- Ensure the BMS is installed in a clean, dry environment, away from excessive heat, moisture, and corrosive substances.
- Avoid exposing the BMS to strong electrostatic discharges. Handle with care, especially during installation.
- Monitor battery cell voltages periodically to ensure they remain within safe operating parameters.
- If the BMS triggers a protection event, identify and resolve the root cause before resuming operation. Do not bypass safety features.
8. User Tips
- Application Specifics: This BMS is suitable for various applications, including household 48V high-power solar energy storage systems and electric scooters like the Laotie ES18 (ensure compatibility with your specific model's voltage and current requirements).
- Pre-charge Consideration: Some users find it beneficial to pre-charge individual cells to a balanced state before connecting them to the BMS, especially if there are significant voltage differences.
- Verify Connections: Double-check all balance wire connections and main power connections before applying power. Incorrect wiring is a common cause of issues.
9. Warranty and Support
Warranty Regulations:
- The warranty service period is 1 year.
- The warranty service is limited to normal use. Man-made damage, self-disassembly, modification and repair, use not in accordance with the instructions, and damage caused by external force majeure factors are not within the scope of free warranty.
- Accessories such as test fixtures are consumables without warranty.
Support:
- When you need warranty service, please contact your dealer for processing.
- If you cannot contact the dealer, you can contact Heltec Energy directly.
- There are no after-sales service stations in other countries except China. If you need warranty service, you may need to send the product to the company for free repair, but you will be responsible for the freight.
For further information, you can refer to the official Heltec Energy website: www.heltec-energy.com