1. Introduction
The Viessmann Vitotron 100 VLN3 is an advanced electric boiler unit designed for efficient heating. This manual provides essential information for the safe and effective installation, operation, and maintenance of your Vitotron 100 VLN3 boiler. The Vitotron 100 offers ease of installation, as it does not require connection to a gas distribution network, construction of a chimney, or a dedicated boiler room. It is designed to be connected to a single or three-phase electrical network, depending on its power requirements. This boiler is compatible with various storage water heaters and buffer containers from the Viessmann product range, and can also integrate with other boiler types.

Figure 1: Front view of the Viessmann Vitotron 100 electric boiler unit.
2. Setup and Installation
The Vitotron 100 VLN3 is designed for straightforward installation. However, due to the electrical and plumbing connections involved, professional installation by a qualified technician is strongly recommended to ensure safety and optimal performance.
2.1 Pre-installation Checks
- Ensure the installation location is dry, well-ventilated, and protected from freezing temperatures.
- Verify that the electrical supply matches the boiler's requirements (24 kW, 380 V, three-phase).
- Confirm that all necessary plumbing connections for the heating system and, if applicable, domestic hot water are available.
2.2 Electrical Connection
Connect the boiler to the appropriate electrical network. The 24 kW model requires a 380 V three-phase connection. All electrical work must comply with local regulations and be performed by a certified electrician.
2.3 Plumbing Connection
Integrate the boiler into your heating system. The Vitotron 100 can be used with Viessmann storage water heaters and buffer containers, or other compatible boiler types. Ensure all pipework is correctly sized and sealed to prevent leaks.
2.4 Initial Fill and Venting
After plumbing connections are complete, fill the heating system with water and thoroughly vent all air from the system to prevent damage and ensure efficient operation.
3. Operating Instructions
Once installed and powered, the Vitotron 100 VLN3 can be operated via its integrated control panel and display.
3.1 Powering On/Off
- To power on the boiler, ensure the main electrical supply switch is in the 'ON' position. The display should illuminate.
- To power off, switch the main electrical supply to 'OFF'.
3.2 Setting Temperature
Use the controls on the display panel to adjust the desired heating water temperature. Refer to the on-screen menu for navigation and temperature adjustment options.
3.3 Operating Modes
The boiler may offer various operating modes (e.g., heating only, heating with domestic hot water priority). Select the appropriate mode via the control panel to match your heating requirements.
3.4 Error Codes and Indicators
The display will show error codes or indicators if a fault occurs. Consult the troubleshooting section or contact a service technician if an error persists.
4. Maintenance
Regular maintenance ensures the longevity and efficient operation of your Vitotron 100 VLN3 boiler. It is recommended that maintenance be performed by a qualified service technician.
4.1 Annual Inspection
Schedule an annual inspection by a professional to check all components, electrical connections, and safety devices.
4.2 System Pressure Check
Periodically check the system pressure gauge. If the pressure is too low, repressurize the system according to the instructions provided by your installer or a qualified technician.
4.3 Cleaning
Keep the exterior of the boiler clean and free from dust and debris. Do not use abrasive cleaners or solvents.
5. Troubleshooting
This section provides basic troubleshooting steps for common issues. For complex problems or persistent faults, contact a qualified service technician.
5.1 No Heat Output
- Check if the boiler is powered on and the main electrical supply is active.
- Verify that the desired temperature setting is correct and not set too low.
- Check the system pressure; if it's too low, the boiler may not operate.
- Look for any error codes on the display panel.
5.2 Boiler Not Turning On
- Ensure the electrical circuit breaker for the boiler has not tripped.
- Check all electrical connections for looseness or damage (only by a qualified electrician).
5.3 Unusual Noises
If you hear unusual noises (e.g., banging, gurgling), it could indicate air in the system or a circulation issue. Contact a technician for diagnosis.
6. Specifications
| Feature | Specification |
|---|---|
| Brand | Viessmann |
| Model Number | Vitotron 100 |
| Type | E932 |
| Power Output | 24 kW |
| Voltage | 380 V |
| Electrical Connection | Three-phase |
| Compatibility | Viessmann storage water heaters, buffer containers, and other boiler types |
7. Warranty and Support
For warranty information, technical support, or service requests, please contact your authorized Viessmann dealer or the seller from whom you purchased the product. Keep your purchase receipt as proof of purchase.