Viessmann Vitotron 100 VLN3

User Manual: Viessmann Vitotron 100 VLN3 Electric Boiler Unit

Model: Vitotron 100 VLN3 | Brand: Viessmann

1. Introduction

The Viessmann Vitotron 100 VLN3 is an advanced electric boiler unit designed for efficient heating. This manual provides essential information for the safe and effective installation, operation, and maintenance of your Vitotron 100 VLN3 boiler. The Vitotron 100 offers ease of installation, as it does not require connection to a gas distribution network, construction of a chimney, or a dedicated boiler room. It is designed to be connected to a single or three-phase electrical network, depending on its power requirements. This boiler is compatible with various storage water heaters and buffer containers from the Viessmann product range, and can also integrate with other boiler types.

Front view of the Viessmann Vitotron 100 electric boiler unit

Figure 1: Front view of the Viessmann Vitotron 100 electric boiler unit.

2. Setup and Installation

The Vitotron 100 VLN3 is designed for straightforward installation. However, due to the electrical and plumbing connections involved, professional installation by a qualified technician is strongly recommended to ensure safety and optimal performance.

2.1 Pre-installation Checks

  • Ensure the installation location is dry, well-ventilated, and protected from freezing temperatures.
  • Verify that the electrical supply matches the boiler's requirements (24 kW, 380 V, three-phase).
  • Confirm that all necessary plumbing connections for the heating system and, if applicable, domestic hot water are available.

2.2 Electrical Connection

Connect the boiler to the appropriate electrical network. The 24 kW model requires a 380 V three-phase connection. All electrical work must comply with local regulations and be performed by a certified electrician.

2.3 Plumbing Connection

Integrate the boiler into your heating system. The Vitotron 100 can be used with Viessmann storage water heaters and buffer containers, or other compatible boiler types. Ensure all pipework is correctly sized and sealed to prevent leaks.

2.4 Initial Fill and Venting

After plumbing connections are complete, fill the heating system with water and thoroughly vent all air from the system to prevent damage and ensure efficient operation.

3. Operating Instructions

Once installed and powered, the Vitotron 100 VLN3 can be operated via its integrated control panel and display.

3.1 Powering On/Off

  • To power on the boiler, ensure the main electrical supply switch is in the 'ON' position. The display should illuminate.
  • To power off, switch the main electrical supply to 'OFF'.

3.2 Setting Temperature

Use the controls on the display panel to adjust the desired heating water temperature. Refer to the on-screen menu for navigation and temperature adjustment options.

3.3 Operating Modes

The boiler may offer various operating modes (e.g., heating only, heating with domestic hot water priority). Select the appropriate mode via the control panel to match your heating requirements.

3.4 Error Codes and Indicators

The display will show error codes or indicators if a fault occurs. Consult the troubleshooting section or contact a service technician if an error persists.

4. Maintenance

Regular maintenance ensures the longevity and efficient operation of your Vitotron 100 VLN3 boiler. It is recommended that maintenance be performed by a qualified service technician.

4.1 Annual Inspection

Schedule an annual inspection by a professional to check all components, electrical connections, and safety devices.

4.2 System Pressure Check

Periodically check the system pressure gauge. If the pressure is too low, repressurize the system according to the instructions provided by your installer or a qualified technician.

4.3 Cleaning

Keep the exterior of the boiler clean and free from dust and debris. Do not use abrasive cleaners or solvents.

5. Troubleshooting

This section provides basic troubleshooting steps for common issues. For complex problems or persistent faults, contact a qualified service technician.

5.1 No Heat Output

  • Check if the boiler is powered on and the main electrical supply is active.
  • Verify that the desired temperature setting is correct and not set too low.
  • Check the system pressure; if it's too low, the boiler may not operate.
  • Look for any error codes on the display panel.

5.2 Boiler Not Turning On

  • Ensure the electrical circuit breaker for the boiler has not tripped.
  • Check all electrical connections for looseness or damage (only by a qualified electrician).

5.3 Unusual Noises

If you hear unusual noises (e.g., banging, gurgling), it could indicate air in the system or a circulation issue. Contact a technician for diagnosis.

6. Specifications

FeatureSpecification
BrandViessmann
Model NumberVitotron 100
TypeE932
Power Output24 kW
Voltage380 V
Electrical ConnectionThree-phase
CompatibilityViessmann storage water heaters, buffer containers, and other boiler types

7. Warranty and Support

For warranty information, technical support, or service requests, please contact your authorized Viessmann dealer or the seller from whom you purchased the product. Keep your purchase receipt as proof of purchase.

Related Documents - Vitotron 100 VLN3

Preview Viessmann Vitotron 100 VMN3/VLN3: Installation and Service Instructions
Official installation and service manual for the Viessmann Vitotron 100 electric system boiler, covering models VMN3 and VLN3. This guide is intended for contractors and details setup, operation, safety, troubleshooting, and maintenance for central heating and optional domestic hot water systems.
Preview Viessmann ViGuide App Remote Monitoring Guide for Boiler Commissioning
Learn how to commission boilers and set up remote monitoring with the Viessmann ViGuide App. This guide provides essential steps for using ViGuide.Viessmann.com and complements detailed installation instructions.
Preview Viessmann Diverting Valve Installation Instructions for Heating Contractors
Detailed installation guide for the Viessmann Diverting Valve (Part Number: 7842241), essential for heating contractors working with CombiPlus modules and Vitodens 100-W B1KA boilers. Covers safety precautions, disassembly, and reassembly steps.
Preview Viessmann Vitodens 100-W Installation and Service Instructions
Comprehensive installation and service manual for Viessmann Vitodens 100-W (Type B1HA, B1KA) gas condensing boilers. This guide provides essential information for contractors on installation, operation, safety, and maintenance.
Preview Viessmann Vitodens 100-W B1HA/B1KA Installation and Service Instructions
This manual provides detailed installation and service instructions for Viessmann Vitodens 100-W B1HA and B1KA gas-fired condensing boilers (Models 26 to 125). It covers safety, regulatory requirements, technical data, installation procedures, troubleshooting, and parts lists, intended for professional heating contractors.
Preview Viessmann Vitodens Control Unit Replacement: Installation Instructions for Contractors
Detailed installation and service guide for replacing the control unit on Viessmann Vitodens heating systems. Covers application information, coding addresses, troubleshooting fault codes, and safety procedures for contractors.