GEYA GRW8 Temperature Control Relay

Contents

GEYA GRW8 Temperature Control Relay User Manual

Brand: GEYA | Model: GRW8 Temperature Control Relay

1. Introduction

The GEYA GRW8 series temperature control relays are designed for precise temperature monitoring and control in various applications. These DIN rail mountable devices are ideal for use in switchboards, heating and cooling systems, and for monitoring temperatures in liquids, radiators, motors, and open spaces. The series includes two main models: GRW8-01 for monitoring a specific temperature point, and GRW8-02 for monitoring a temperature range.

GEYA GRW8-01 and GRW8-02 Temperature Control Relays with Sensors
Figure 1: GEYA GRW8-01 and GRW8-02 Temperature Control Relays with various sensor lengths.

2. Key Features

  • Models: GRW8-01 for single-point temperature monitoring (relay active if temperature is low or high), GRW8-02 for temperature range monitoring (relay active only within set high/low temperature values, turns off if outside range).
  • Sensor: Includes a waterproof stainless steel sensor head with silicone rubber cable wire (available in 0.5m, 1m, 2m, 3m, 5m lengths).
  • Monitoring: Function for short-circuit or sensor disconnection monitoring.
  • Control Mode: Possibility to set function to "heating" or "cooling" (GRW8-01).
  • Direct Sensor Placement: Sensor can be placed directly on the terminal block for temperature monitoring within a switchboard or its surroundings.
  • Temperature Range: -15°C to +45°C.
  • Hysteresis: Adjustable from 0.5°C to 5°C.
  • Universal Supply: AC/DC 24V-240V.
  • Output: 1 SPST (Single Pole Single Throw) 16A/AC1.
  • Indicators: Green LED for supply status, Red LED for relay status.
  • Mounting: 1-MODULE, DIN rail mounting.

3. Technical Specifications

Technical parameters table for GEYA GRW8-01 and GRW8-02 Temperature Control Relays
Figure 2: Technical Parameters for GRW8-01 and GRW8-02.
Table 1: Detailed Technical Parameters
ParameterGRW8-01 (Temperature control)GRW8-02 (Temperature range control)
FunctionTemperature controlTemperature range control
Supply terminalsA1-A2
Rated supply voltageAC/DC 24V-240V
Rated supply frequency50/60Hz
Burdenmax 2VA
Supply voltage tolerance-15%; +10%
Temperature range-15°C to +45°C
Hysteresis0.5°C to 5°C
Supply indicationgreen LED
Measurement accuracy±2°C
Output1 SPST
Current rating16A/AC1
Switching voltage250VAC/24VDC
Min. breaking capacity DC500mW
Output indicationred LED
Mechanical life1 × 107
Electrical life (AC1)1 × 105
Operating temperature-20°C to +55°C (-4°F to 131°F)
Storage temperature-35°C to +75°C (-22°F to 158°F)
Mounting/DIN railDin rail EN/IEC 60715
Protection degreeIP40 for front panel/IP20 terminals
Operation positionany
Overvoltage categoryIII.
Pollution degree2
Max. cable size (mm2)solid wire max. 1×2.5 or 2×1.5 / with sleeve max. 1×2.5 (AWG 12)
Dimensions90 × 18 × 64mm

4. Package Contents

The package typically includes:

  • 1 x GEYA GRW8 Temperature Control Relay Unit (GRW8-01 or GRW8-02)
  • 1 x Waterproof NTC Sensor (length varies: 0.5m, 1m, 2m, 3m, or 5m)

5. Safety Information

WARNING: Risk of electric shock. Installation and maintenance should only be performed by qualified personnel.

  • Always disconnect power before installing or servicing the device.
  • Ensure all wiring connections are secure and comply with local electrical codes.
  • Do not exceed the specified voltage and current ratings.
  • Keep the device away from moisture and extreme temperatures outside its operating range.
  • Use appropriate personal protective equipment (PPE) during installation.

6. Setup and Installation

6.1. Mounting

The GRW8 series relays are designed for DIN rail mounting (EN/IEC 60715). Simply clip the device onto a standard 35mm DIN rail within your electrical enclosure.

6.2. Wiring

Refer to the wiring diagram below for proper connections. Ensure all connections are tight and correct before applying power.

GEYA GRW8 Wiring Diagram
Figure 3: Wiring Diagram for GRW8-01 and GRW8-02.
  • Power Supply (Un): Connect the AC/DC 24V-240V power supply to terminals A1 and A2.
  • NTC Sensor: Connect the waterproof NTC sensor to terminals T1 and T2. The sensor can also be directly connected to these terminals if monitoring ambient temperature within the enclosure.
  • Output Contact: The relay features a 1 SPST output contact. Connect your load to terminals 11 and 14. This is a normally open (NO) contact.

6.3. Example Wiring

Below are examples of how to wire the GRW8-01 and GRW8-02 for typical applications.

Example wiring for GEYA GRW8-01 (Cooling/Heating) and GRW8-02 (Lamp) with dimensions
Figure 4: Example Wiring for GRW8-01 (Cool/Heat) and GRW8-02, along with device dimensions.
  • GRW8-01 COOL: Connect a fan to the output (11-14) to activate when the temperature exceeds the set point (cooling mode).
  • GRW8-01 HEAT: Connect a heater to the output (11-14) to activate when the temperature falls below the set point (heating mode).
  • GRW8-02: Connect a lamp or other indicator to the output (11-14) to activate when the temperature is within the set range.

7. Operating Instructions

7.1. Panel Overview

GEYA GRW8-01 and GRW8-02 Panel Diagram
Figure 5: Panel Diagram for GRW8-01 and GRW8-02.

7.2. Setting Parameters

  • GRW8-01 (Single Temperature Control):
    - Temperature Knob: Use the top knob to set the desired temperature (from -15°C to +45°C).
    - Hysteresis Knob: Use the bottom knob to set the hysteresis (0.5°C to 5°C). This determines the temperature difference before the relay changes state again.
    - COOL/HEAT Switch: Select 'COOL' for cooling applications (relay activates when temperature rises above set point) or 'HEAT' for heating applications (relay activates when temperature falls below set point).
  • GRW8-02 (Temperature Range Control):
    - TH Knob: Use the top knob to set the High Temperature threshold (TH).
    - TL Knob: Use the middle knob to set the Low Temperature threshold (TL).
    - Hysteresis Knob: Use the bottom knob to set the hysteresis (0.5°C to 5°C).

7.3. LED Indicators

  • Green LED (Un): Illuminates when the power supply is connected and the device is powered on.
  • Red LED (R): Illuminates when the output relay is active (contact 11-14 is closed).

7.4. Function Diagrams

The following diagrams illustrate the operational logic for each model:

GEYA GRW8-01 and GRW8-02 Function Diagrams
Figure 6: Function Diagrams for GRW8-01 and GRW8-02.

8. Maintenance

  • Cleaning: Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Inspection: Periodically check all wiring connections for tightness and signs of wear or damage.
  • Sensor Care: Ensure the waterproof sensor head is not damaged and its cable is intact. Avoid sharp bends or excessive pulling on the sensor cable.

9. Troubleshooting

Table 2: Common Troubleshooting Steps
ProblemPossible CauseSolution
Device not powering on (Green LED off)No power supply, incorrect voltage, loose connections.Check power supply to A1/A2. Verify voltage is within 24V-240V. Tighten connections.
Relay not switching (Red LED off/on incorrectly)Incorrect temperature/hysteresis settings, faulty sensor, sensor disconnection.Verify set temperature and hysteresis. Check sensor connections (T1/T2). Replace sensor if faulty. Ensure COOL/HEAT mode is correct (GRW8-01).
Inaccurate temperature readingsSensor placement, damaged sensor.Ensure sensor is placed in the correct environment for measurement. Check sensor for physical damage.
Load not controlledIncorrect load wiring, faulty load, relay contact overload.Check load wiring to 11/14. Test the load independently. Ensure load current does not exceed 16A.

10. User Tips

  • Accuracy: Users report the device works quite accurately, making it reliable for critical temperature control.
  • Ease of Use: The relay is generally considered easy to assemble and configure, even for those new to such devices.
  • Sensor Length: Choose the appropriate sensor cable length (0.5m, 1m, 2m, 3m, or 5m) for your specific application to avoid unnecessary cable length or extensions.

11. Warranty and Support

GEYA products are manufactured to high-quality standards and are certified according to CCC, CE, CB, SAA, SEMKO, TUV, and RoHS. For specific warranty details, technical support, or service inquiries, please contact your retailer or the GEYA customer service directly. Always refer to the official GEYA website or documentation for the most up-to-date support information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.