1. Introduction
The PowMr PVS-6KW is a multi-function inverter/charger designed for solar power systems. It features a comprehensive LCD display for user-configurable settings and easy operation. This inverter is specifically designed for battery-free operation and does not include any battery-related settings. It supports both solar and grid power inputs.
1.1 Key Features
- Pure sine wave output for stable operation and compatibility with sensitive equipment.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Grid-tie capability based on application via LCD setting.
- Compatible with mains voltage.
- Automatic restart upon AC recovery.
- Protection against overload, over temperature, and short circuit.
- Cold start function.
- Full load operation with solar power only.
1.2 Basic System Architecture
The inverter integrates into a solar power system that typically includes PV modules and may connect to a utility grid. It can power various appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.

Figure 1: Battery-Free Operation with CT-Controlled Anti-Feedback System.

Figure 2: Smart Load Allocation with Solar Priority Power Supply.
2. Safety Instructions
WARNING:
- This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Only qualified service persons are able to service this device. If errors still persist after following troubleshooting, please send this inverter/charger back to local dealer or service center for maintenance.
- Before using the unit, read all instructions and cautionary markings on the unit and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- For optimum operation, follow required specifications to select appropriate cable size.
- Strictly follow installation procedures when disconnecting AC or DC terminals.
- This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- Never cause AC output and DC input short circuits. Do not connect to the mains when DC input short circuits.
3. Product Overview
The inverter features a robust design with clear indicators and connection ports.

Figure 3: Front View of the Inverter.

Figure 4: Rear View with Connection Ports.
3.1 Components
- LCD display
- Status indicator
- Fault indicator
- Function buttons
- Anti-dust kit
- WIFI communication/RS-232 port
- Power on/off switch
- Current Transformer (CT) port
- AC input
- AC output
- PV input
4. Setup and Installation
4.1 Unpacking and Inspection
Before installation, inspect the unit for any damage. The package should contain:
- Inverter unit x 1
- User manual x 1
- Current Transformer (optional) x 1
- WIFI module (optional) x 1
4.2 Preparation
Before connecting any lines, remove the screws under the machine and detach the bottom cover plate.
4.3 Mounting the Unit
Consider the following points for installation:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install at eye level for easy LCD display reading.
- Allow approximately 20 cm clearance to the sides and 50 cm above and below for proper air circulation and heat dissipation.
- Ambient temperature should be between 0°C and 55°C for optimal operation.
- Recommended installation position is vertically on a wall.
- Ensure enough space for heat dissipation and wire removal.
CAUTION:
Suitable for mounting on concrete or other non-combustible surfaces only. Install the unit using M4 or M5 screws.
4.4 AC Input/Output Connection
CAUTION:
- Install a separate AC breaker between the inverter and AC input power source. Recommended AC breaker specs: 32A for 4KW, 50A for 6KW, and 85A for 10KW.
- Do NOT mis-connect input and output connectors. Terminal blocks are marked "IN" and "OUT".
WARNING:
- All wiring must be performed by qualified personnel.
- Use appropriate cable for AC input connection. Refer to the table below for recommended cable sizes.
| Model | Wire size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4KW | 12AWG | 4 | 1.2N·m |
| 6KW | 10AWG | 6 | 1.2N·m |
| 10KW/15KW | 8AWG | 6 | 1.2N·m |
Steps for AC Input/Output Connection:
- Before connecting, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation from the six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities (L, N, Ground) indicated on the terminal block and tighten the screws.
- Insert AC output wires according to polarities (L, N, Ground) and tighten screws.
- Ensure all wires are securely connected.
CAUTION:
Appliances like air conditioners require 2-3 minutes to restart. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter may trigger an overload fault to protect the appliance, but internal damage might still occur.
4.5 PV Connection
CAUTION:
- Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
- Use appropriate cable for PV module connection. Refer to the table below for recommended cable sizes.
| Model | Wire size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4KW/6KW/10KW/15KW | 1x12AWG | 4 | 1.2N·m |
PV Module Selection:
When selecting PV modules, consider the following parameters:
- Open circuit Voltage (Voc) of PV modules should not exceed the max. PV array open circuit voltage of the inverter (500Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than 60V.
For example, using 650Wp PV modules (Vmp: 44.33V, Imp: 14.64A, Voc: 52.93V, Isc: 15.37A, Cells: 288(144x2)):
| Solar input (Min in serial: 3 pcs, max. in serial: 9 pcs) | Quantity of panels | Total input power |
|---|---|---|
| 3 pcs in serial | 3 pcs | 1950W |
| 7 pcs in serial | 7 pcs | 4500W |
| 9 pcs in serial | 9 pcs | 5840W |
| 7 pieces in serial and 2 sets in parallel | 14 pcs | 9000W |
| 9 pieces in serial and 2 sets in parallel | 18 pcs | 11680W |
| 7 pieces in serial and 3 sets in parallel | 21 pcs | 13500W |
PV Module Wire Connection:
- Remove 10mm of insulation from positive and negative conductors.
- Use bootlace ferrules on the ends of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) of PV input connector. Connect negative pole (-) to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.

Figure 5: PV Module Wire Connection Diagram.
4.6 Current Transformer (CT) Connection
Connect the CT connector at the bottom of the machine. Connect the left terminal to the positive terminal and the right terminal to the negative terminal.

Figure 6: Current Transformer Connection Diagram.
Note: For CTs not part of the original factory configuration, the wiring pins must be connected to positions 5 (positive) and 6 (negative).
How to determine if the CT is connected in reverse: Under normal circumstances, with CT settings enabled, correct wiring, and both mains power and PV present, no current should feed into the grid. If the positive and negative poles of the CT are reversed, current may feed into the grid.
4.7 Final Assembly
After connecting all wirings, replace the bottom cover by screwing the two screws back into place.
4.8 Communication Connection
The inverter supports Wi-Fi cloud communication (optional). Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP from the APP store and refer to the "Wi-Fi Plug Quick Installation Guideline" for network setup and registration. The inverter status can be monitored via the mobile phone APP or a computer webpage.
5. Operating Instructions
5.1 Power ON/OFF
Once the unit is properly installed, simply press the power on/off switch (located on the bottom of the case) to turn on the unit.
5.2 Operation and Display Panel
The operation and display panel on the front of the inverter includes secondary indicators, four function keys, and an LCD display, showing operating status and input/output power information.

Figure 7: LCD Display and Function Keys.
LED Indicators:
- AC (Green, Solid On): Output is powered by utility in Line mode.
- INV (Green, Solid On): Output is powered by PV.
- FAULT (Red, Solid On): Fault occurs in the inverter.
- FAULT (Red, Flashing): Warning condition occurs in the inverter.
Function Keys:
- ESC: To exit setting mode.
- UP: To go to previous selection.
- DOWN: To go to next selection.
- ENTER: To confirm selection in setting mode or enter setting mode.
5.3 LCD Display Icons
The LCD displays various icons to indicate the inverter's status and operation mode.
| Icon | Function description |
|---|---|
![]() | This image contains a comprehensive table of LCD display icons and their corresponding functions, including input source information (AC, PV), configuration and fault information (setting programs, warning/fault codes), output information (voltage, frequency, load percent, VA, Watt), load information (overload), and mode operation information (mains connection, PV panel connection, utility power supply, DC/AC inverter circuit working, alarm disabled). |
5.4 LCD Setting
Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm, or ESC to exit.
Refer to the user manual PDF for detailed tables of configurable settings (Program 00-86) including output source priority, AC input voltage range, auto-restart options, output frequency, output voltage, alarm control, display settings, grid-tie operation, CT ratio, and time settings.
You can view the full PDF manual for detailed LCD settings and options: PowMr PVS-6KW User Manual (PDF)
5.5 Display Setting
The LCD display information cycles through various parameters by pressing the UP or DOWN keys. This includes input/output voltage, input frequency, PV voltage, PV input current, PV power, output frequency, load percentage, load in VA, load in Watt, daily/monthly/gross power generation, date, time, model, hardware, and software version numbers.

Figure 8: Example of LCD Display Information.
5.6 Operating Mode Description
The LCD will show different information depending on the operating mode (Standby, Line Mode). For detailed display examples in each mode, please refer to the full user manual PDF.
6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit
The inverter comes with a pre-installed anti-dust kit. This kit helps maintain internal temperature and increases product reliability in harsh environments.
Maintenance Steps:
- Loosen the screw on the top of the inverter in a counterclockwise direction.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case.
- After cleaning, re-assemble the dust-kit back into the inverter.
NOTICE:
The anti-dust kit should be cleaned every month.
7. Troubleshooting
If you encounter any issues, refer to the table below for common problems and solutions. If the problem persists, contact a qualified service person or the service center.
| Fault Code | Fault Event / Explanation | What to do |
|---|---|---|
| 01 | Fan is locked when inverter is off. | Replace the fan. |
| 02 | Over temperature. | Check whether the air flow is blocked or if the ambient temperature is too high. |
| 05 | Output short circuited or over temperature is detected by internal converter components. | Check if wiring is connected well and remove abnormal load. |
| 06/58 | Output abnormal (Inverter voltage below 190Vac or higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center. |
| 07 | Overload error. The inverter is overloaded (102%) and time is up. | Reduce the connected load by switching off some equipment. |
| 08/53/57 | Internal components failed. | Return to repair center. |
| 51 | Over current or surge. | Restart the unit. If the error happens again, return to repair center. |
| 52 | Bus voltage is too low. | Restart the unit. If the error happens again, return to repair center. |
| 55 | Output voltage is unbalanced. | Restart the unit. If the error happens again, return to repair center. |
7.1 Warning Indicator
The inverter provides audible alarms and flashing icons for various warning conditions.
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | Fault icon |
| 02 | Temperature sensor not connected. | Beep one time every second | Fault icon |
| 07 | Overload. | Beep once every 0.5 second | Fault icon |
| 10 | Output power derating. | Beep twice every 3 seconds | Fault icon |
| 15 | PV energy is low. | Beep twice every 3 seconds | Fault icon |
| 16 | PV voltage high. | Beep twice every 3 seconds | Fault icon |
8. Specifications
Detailed technical specifications for the PowMr PVS-6KW Solar Inverter.
| Parameter | Specification |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 170Vac±7V(UPS) / 90Vac±7V(APL) |
| Low Loss Return Voltage | 180Vac±7V(UPS) / 100Vac±7V(APL) |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| Transfer Time | 10ms typical (UPS) |
| Parameter | Specification |
|---|---|
| Rated Output Power | 6KW |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 230Vac±5% |
| Output Frequency | 50Hz |
| Overload Protection | 3s @ ≥150% load; 5s@101%~150% load |
| Surge Capacity | 2* rated power for 5 seconds |
| No Load Power Consumption | 30W |
| Parameter | Specification |
|---|---|
| Max. PV Array Power | 6750W |
| Nominal PV Voltage | 250Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc |
| Number of MPPT Trackers/Maximum Input Current | 18A |
| Parameter | Specification |
|---|---|
| Nominal Output Voltage | 220/230/240Vac |
| Feed-in Grid Voltage Range | 195Vac~253Vac |
| Feed-in Grid Frequency Range | 50±1Hz/60±1Hz |
| Nominal Output Current | 26.5A |
| Power Factor Range | >0.99 |
| Maximum Conversion Efficiency (DC/AC) | 97% |
| Parameter | Specification |
|---|---|
| Safety Certification | CE |
| Operating Temperature Range | -10°C ~ 50°C |
| Storage Temperature | -15°C ~ 60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
9. Warranty and Support
The PowMr PVS-6KW Solar Inverter comes with a 12-month warranty.
9.1 Contact Information
For technical support, warranty claims, or service, please contact:
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTDTel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
10. User Tips
- Battery-Free Operation: This inverter is designed to operate without batteries. It cannot be used with batteries, including LiFePo4 or automotive batteries.
- Grid-Tie Capability: The inverter supports grid-tie operation, allowing excess solar energy to be fed back into the grid. Ensure local regulations permit this.
- Smart Energy Management: The built-in smart energy management system prioritizes solar power to supply loads. When solar power is insufficient or at night, grid power takes over to ensure stable operation.
- WIFI Module: Consider purchasing the optional WIFI module for remote monitoring and management via a mobile app or web interface.
11. Product Video
Watch this video for a quick overview of the PowMr PVS-6KW Solar Inverter and its features.
Video: Overview of the PowMr PVS-6KW Solar Inverter, highlighting its features and easy wiring for solar power systems.