1. Introduction
The SALORIE 28 Modes TENS EMS Physiotherapy Massager is a modern home therapy device designed to provide relief from pain, muscle tension, stress, and improve circulation. Utilizing advanced bio-electrical technology, it delivers relaxing, deep soothing sensations to various parts of the body. This device combines Transcutaneous Electrical Nerve Stimulation (TENS) and Electrical Muscle Stimulation (EMS) to target nerve and muscle aches.
Please read this manual carefully before using the instrument to ensure safe and effective operation.
2. Package Contents
Before starting, please check the contents of your package:
- 1 x Electric Therapy Machine (Host Device)
- 1 x Touch-Pen
- 6 x Electrode Pads (2 Large, 4 Medium)
- 2 x Electrode Wires (Dual Leads)
- 1 x AC/DC Adapter (EU/US/AU/UK plug type may vary)
- 1 x USB Cable
- 1 x Pad Holder
- 1 x English User Manual
- 1 x Application Acupoint Chart

Figure 2.1: All items included in the package.
3. Setup
3.1 Charging the Device
The device is powered by an internal rechargeable lithium battery (400mAh). Before first use or when the battery level is low, charge the device:
- Connect the small end of the USB cable to the USB Charger Port on the device (located at the top between output ports A and B).
- Connect the other end of the USB cable to the AC/DC adapter.
- Plug the AC/DC adapter into a standard wall outlet (AC 100-240V). Alternatively, you can connect the USB cable to a computer's USB port.
- A full charge typically takes around 4 hours. The battery indicator on the LCD screen will show charging status.
3.2 Connecting Electrode Pads
- Connect the electrode wires to the output ports (A or B) at the top of the device.
- Attach a pair of electrode pads to each dual-lead wire by snapping them onto the connectors.
- Carefully remove the protective film from the back of the electrode pads.
- Place the two pads on the desired muscle area, ensuring both pads are fully on the skin and not overlapping.

Figure 3.1: Close-up of device ports (A, USB, B) and control buttons.
4. Operating Instructions
4.1 Device Overview

Figure 4.1: Front view of the device with labeled buttons and ports.
- Big LCD Touch-screen: Displays mode, intensity, timer, and battery status.
- Power ON/OFF: Side button to turn the device on or off.
- '-' Intensity Adjustment: Decreases intensity for the selected channel.
- '+' Intensity Adjustment: Increases intensity for the selected channel.
- A&B Channels Switch: Toggles between Channel A and Channel B to adjust their respective intensities.
- Modes Switch (M): Cycles through the 28 available massage modes.
- Duration Setting (T): Adjusts the treatment timer.
- A Output Connector: For connecting electrode wire for Channel A.
- B Output Connector: For connecting electrode wire for Channel B.
- USB Charger Port: For charging the device.
4.2 Basic Operation
- Power On: Press and hold the Power ON/OFF button on the side of the device. The LCD screen will light up, and the device will start in Mode 1.
- Select Mode: Press the 'M' (Modes Switch) button to cycle through the 28 available massage modes. Observe the icons on the screen to select your preferred mode.
- Adjust Intensity: Once a mode is selected, press the '+' button to gradually increase the intensity or the '-' button to decrease it. The intensity level (0-20) is displayed on the screen. You can adjust intensity for Channel A and Channel B independently by pressing the A&B Channels Switch button to select the desired channel first.
- Set Timer: Press the 'T' (Duration Setting) button to adjust the treatment time. The default time is 20 minutes, and it can be set from 10 minutes up to 60 minutes in 10-minute increments.
- Power Off: After your session, press and hold the Power ON/OFF button to turn off the device.
4.3 Electrode Pad Placement
Proper pad placement is crucial for effective therapy. Refer to the included Acupoint Chart for specific guidance.
- Identify Pain Point: Find the exact point of pain or the muscle group you wish to stimulate.
- Twin Mode: Place two pads next to each other on the same side of the body and in close proximity (e.g., on a single muscle).
- Opposed Mode: Place two pads on a similar spot but on opposite sides of the body (e.g., front and back of the shoulder, or on opposing muscle groups).

Figure 4.2: General electrode pad placement for various body areas.

Figure 4.3: Specific pad placement for common pain areas.
4.4 Application Principles
- Intensity: Adjust the intensity gradually to a level where you feel muscular vibration and involuntary muscle movements, but it should always be comfortable and not painful. It is often more effective to reach the highest intensity level you can comfortably tolerate.
- Duration: Recommended application duration is 2-3 times per day for 40-60 minutes per application.
- Course: A typical course of treatment is 10 days.
4.5 Mode Descriptions
The device offers 28 pre-programmed modes. Experiment with different modes to find what works best for your needs.

Figure 4.4: Device display showing the 28 available modes.
| Mode | Name | Description |
|---|---|---|
| 1 | Tuina | Traditional Chinese massage technique. |
| 2 | Acupuncture | Stimulates acupuncture points. |
| 3 | Tapping | Rhythmic tapping sensation. |
| 4 | Crosscut Fist | Intended for deep muscle stimulation. |
| 5 | Kneading Massage | Deep tissue kneading action. |
| 6 | Footplate Massage | Effective for foot reflexology points. |
| 7 | Acupuncture Kneading | Combination of acupuncture and kneading. |
| 8 | Ear Press Kneading | Specific for ear acupressure points. |
| 9 | Lateral Palm Kneading | Massage using the side of the palm. |
| 10 | Reflexology | Stimulates reflex zones. |
| 11 | Lifting Pinching | Lifting and pinching manipulation. |
| 12 | Shiatsu | Finger pressure massage technique. |
| 13 | Foot Reflexology | Specific reflexology for feet. |
| 14 | Trigger | Targets trigger points for pain relief. |
| 16 | Strike Pulse Current | Strong, striking pulse. |
| 17 | Stepping | Stepping-like rhythmic stimulation. |
| 18 | Stretching | Mimics stretching movements. |
| 19 | Swedish Thai | Combination of Swedish and Thai massage. |
| 20 | Rubbing | Gentle rubbing sensation. |
| 21 | Nudge | Light, nudging pulses. |
| 23 | Weight Loss | Stimulation designed for body shaping. |
| 24 | Shiatsu Deep | Deeper Shiatsu pressure. |
| 25 | Acupuncture | Another variation of acupuncture stimulation. |
| 26 | Pressure Bo | Pressure-based stimulation. |
| 28 | Auto Combination | Automatically cycles through various modes. |
5. Maintenance
5.1 Cleaning and Care of Electrode Pads
To prolong the life and effectiveness of your electrode pads:
- Ensure your skin is clean and free from dirt, oil, or lotions before applying pads.
- After use, put a few drops of water on your fingers and gently rub them on both sides of the pads. This helps maintain their adhesiveness.
- Always turn off the device before removing or repositioning the electrodes.
- After each session, place the protective film back onto the pads or store them on the provided pad holder.
- Do not use electrodes that do not stick properly or only partially stick to the skin.
- Only use the electrodes supplied by the manufacturer. Do not use electrodes on different people.
5.2 Device Storage
- Store the device and accessories in a dry place, away from direct sunlight.
- Avoid storing in areas with high temperature (above 60°C / 140°F) or high humidity (above 80% relative humidity).
- Storage Temperature Range: -20°C to 60°C (-4°F to 140°F).
- Atmospheric Pressure: 80KPa to 105KPa.
6. Troubleshooting
| Problem | Possible Cause / Solution |
|---|---|
| Unit not turning on / Screen is blank | Battery may be depleted. Charge the device for at least 1 hour. Ensure the power button is pressed and held. |
| Unit not charging | Ensure USB cable is firmly connected to device and adapter/computer. Check if the AC adapter is plugged into a live socket. Try a different USB cable or adapter. |
| No sensation from pads when unit is on | Ensure lead wires are firmly connected to device and pads. Verify 2 pads are connected per wire. Ensure pads are placed in close proximity on the skin and not too far apart or on different limbs. Increase intensity gradually. |
| No sensation in feet (e.g., when using footplate) | You may need a higher intensity setting for feet, especially with poor circulation or nerve damage. |
| Only one output port works | Test with a different lead wire and set of pads in the problematic port to isolate if the issue is with the port, wire, or pads. |
| One pad feels stronger than the other | This is normal as different body areas react differently. Ensure both pads are making good contact with the skin. |
| Painful burning sensation on skin during use | Ensure adhesive gel pads are adhering firmly. Pads might be too dry and need replacement. Stop use immediately if irritation occurs. |
| Stimulation has weakened | Battery may be low; recharge the device. Pads may be losing adhesiveness; clean them or replace if necessary. |
7. Specifications
| Feature | Specification |
|---|---|
| Product Name | Electronic Pulse Massager TENS EMS |
| Brand | SALORIE |
| Application Area | Full Body |
| Massage Modes | 28 Modes |
| Intensity Levels | 20 Levels |
| Output Channels | Dual Output (A & B) |
| Electrode Pads | 6 pcs (2 Large, 4 Medium) |
| Power Supply | Rechargeable Lithium Battery (400mAh) |
| Charging Voltage | DC 100-240V (via AC adapter) |
| Display | Large Backlit LCD Touch-screen (8.3 x 4.5 cm) |
| Timer | Adjustable (10-60 minutes) |
| Functions | Massage, Acupuncture, Knead, Relax |
| Device Dimensions | 13 cm (H) x 6.5 cm (W) x 1 cm (D) |
| Origin | Mainland China |

Figure 7.1: Device dimensions.
8. Safety Warnings and Contraindications
8.1 General Warnings
- Do not apply stimulation directly over the heart, on the neck area (front or sides), or on the temples.
- Apply electrode pads only to normal, intact, clean skin. Do not apply over open wounds, swollen, or infected areas.
- Never use the device while driving, operating machinery, or during activities where involuntary muscle contractions may endanger yourself or others.
- Do not use the device in the bath or shower, or immerse it in any liquid.
- Never use the device while sleeping.
- This device should only be used with accessories provided by the manufacturer.
- If skin irritation or redness occurs after stimulation, do not use the device again until the skin has fully recovered. Consult a medical professional if irritation persists.
- This device is intended for use by adults. Use on children should only occur with adult supervision.
8.2 Contraindications
DO NOT use the device if you have any of the following medical conditions:
- An implanted cardiac pacemaker, defibrillator, or other implanted metallic or electronic device.
- Are pregnant (under 37 weeks).
- Have epilepsy.
It is recommended that you consult your medical practitioner before use if you:
- Have been diagnosed with cancer.
- Have suffered a recent surgical procedure.
- Have cardiac problems or cardiac disease.
- Have an abdominal hernia.
- Have venous thrombosis.
8.3 Adverse Reactions
If you experience skin irritations, burns beneath the electrode pads, or any other adverse reactions, treatment should be stopped immediately. Consult with your medical practitioner about further use of the device.
9. User Tips
- For optimal pain relief, gradually increase the intensity to the highest level you can comfortably tolerate.
- A full charge can provide up to 4-6 hours of continuous use, with some users reporting up to 12 hours depending on intensity settings.
- Always ensure good skin contact with the pads for consistent and effective stimulation.
- Experiment with different modes and pad placements to find the most effective combination for your specific needs.
10. Product Video
Video 10.1: Product unboxing and demonstration of features.
11. Warranty and Support
For any warranty claims, technical support, or inquiries regarding your SALORIE 28 Modes TENS EMS Physiotherapy Massager, please contact the seller or retailer from whom you purchased the product. Keep your proof of purchase for any warranty-related services.