1. Introduction and Overview
This manual provides comprehensive instructions for the TENSTAR ROBOT PWM to Voltage Converter Module (LC-LM358-PWM2V) and the Voltage to Frequency Converter Module (LM331_V2F). These modules are designed for signal interface switching in various applications, including PLC and MCU industrial control boards.
The LC-LM358-PWM2V module efficiently converts PWM digital signals (0%-100% duty cycle) into a stable 0-10V analog voltage output. The output voltage is precisely regulated by adjusting the PWM duty ratio. It features MCU embedded technology and allows fine-tuning via a potentiometer.
The LM331_V2F module converts an analog voltage input (0-10V) into a corresponding frequency pulse signal (0-10KHz). This module is also fine-tunable via a potentiometer to ensure accurate voltage-to-frequency correspondence.
Both modules are compact, making them suitable for integration into diverse electronic projects and industrial systems.
2. Specifications
2.1. PWM to Voltage Converter Module (LC-LM358-PWM2V)
- Work Voltage: DC 12V-30V (> 100mA)
- PWM Receiver Frequency: 1KHz-3KHz
- PWM Signal Input Level Range:
- 4.5V to 10V peak (for normal controller or 5V MCU, short cap installed in '5V' position)
- 12V to 24V peak (for normal PLC controller, short cap installed in '24V' position)
- Conversion Range: 0%-100% PWM to 0-10V
- Allowable Error: 5%
- Features: MCU embedded technology, potentiometer for fine-tuning, small size.
2.2. Voltage to Frequency Converter Module (LM331_V2F)
- Working Voltage: 13.5V-30V
- Input Controllable Voltage Range: 0-10V
- Output Frequency Range: 0-10KHz
- Output Signal: Fine-tunable via potentiometer.
- Output Types: Two independent outputs: OC-OUT (NPN collector output) and FOUT (IC output).
3. Setup and Hardware Interface
3.1. PWM to Voltage Converter Module (LC-LM358-PWM2V)
Refer to the diagram below for the module's layout and pin assignments. Ensure correct polarity and voltage levels during connection.

Figure 1: Front view of the LC-LM358-PWM2V module.

Figure 2: Back view of the LC-LM358-PWM2V module, showing GND, VCC, VOUT, and PWM pins.
Pin Assignments:
| Pin | Description |
|---|---|
| VCC | DC 12V-30V Power Supply Input |
| GND | Power Supply Ground |
| PWM | Positive input for PWM signal |
| GND | Negative input for PWM signal |
| VOUT | Analog Voltage Output (0-10V) |
| GND | Output Voltage Ground |

Figure 3: Detailed pinout and description for the PWM to Voltage Module.
PWM Signal Input Level Selection:
The module features a short cap for selecting the appropriate PWM input level:
- For PWM signals with a peak of 4.5V to 10V (e.g., from a 5V MCU), install the short cap in the '5V' position.
- For PWM signals with a peak of 12V to 24V (e.g., from a PLC controller), install the short cap in the '24V' position.
3.2. Voltage to Frequency Converter Module (LM331_V2F)
Refer to the diagram below for the module's layout and pin assignments. Ensure correct polarity and voltage levels during connection.

Figure 4: Detailed pinout and description for the Voltage to Frequency Module.
Pin Assignments:
- VCC: Working Power Supply (13.5V-30V)
- GND: Power Ground
- IN+: Input Voltage (0-10V)
- IN-: Input Ground
- OCOUT: Signal Collector Output Port (NPN, for driver connection)
- FOUT: Frequency Output Port (IC output)
Driver Connection Notes:
When connecting the OCOUT to a driver for pulse signals, use a common anode connection. The relevant wiring is as follows:
- Connect OCOUT to PUL- or PUL12-30V on the driver.
- Connect PUL+ or the common terminal +5V on the driver.
- If powering with 12V, a 330R resistor must be connected in series to limit current.
- If powering with 13-24V, a 2.7K resistor must be connected in series to limit current.
The common cathode end is matched with the negative GND of the power supply.
4. Operating Instructions
4.1. PWM to Voltage Converter Module (LC-LM358-PWM2V)
- Power On: Apply DC 12V-30V to the VCC and GND terminals. Without an input PWM signal, the output voltage (VOUT) will be 0V. An input signal is required for output.
- Initial Calibration: For optimal accuracy, perform a calibration upon first use or if the input frequency changes significantly.
- Input a PWM signal with a 50% duty cycle to the PWM/GND terminals. The frequency should be between 1KHz and 3KHz.
- Measure the voltage between VOUT and GND using a multimeter. It should display approximately 5V.
- Adjust the onboard potentiometer (labeled 'W 103' or similar) until the multimeter reads exactly 5.00V. This calibrates the module to your pulse signal.
- Operation: Once calibrated, the output voltage at VOUT will directly correspond to the duty cycle of the input PWM signal (0%-100% PWM to 0-10V). Adjust the input PWM duty cycle to achieve the desired analog output voltage.
- Accuracy Adjustment: The potentiometer can be used to fine-tune the output voltage accuracy if minor adjustments are needed.
4.2. Voltage to Frequency Converter Module (LM331_V2F)
- Power On: Apply DC 13.5V-30V to the VCC and GND terminals.
- Input Voltage: Connect your analog input voltage (0-10V) to the IN+ and IN- terminals.
- Frequency Output: The module will generate a corresponding frequency pulse signal at the FOUT terminal.
- Correspondence: The standard conversion is 1V = 1KHz, up to 10V = 10KHz.
- Calibration: If there is a deviation in the voltage-to-frequency correspondence, adjust the potentiometer on the board to calibrate it.
- Driver Output: For connecting to a driver, use the OCOUT (NPN collector output) or FOUT (IC output) terminals as described in the "Setup and Hardware Interface" section.
5. Maintenance
These modules are designed for reliable operation with minimal maintenance. To ensure longevity and optimal performance:
- Keep the module clean and free from dust and moisture.
- Avoid exposing the module to extreme temperatures or direct sunlight.
- Ensure proper ventilation if operating in an enclosed space.
- Regularly check connections for secure contact.
- Do not exceed the specified operating voltage ranges.
6. Troubleshooting
If you encounter issues with the module, consider the following:
- No Output Voltage (PWM to Voltage):
- Verify that the module is powered correctly (DC 12V-30V).
- Ensure a valid PWM signal is being input to the PWM/GND terminals.
- Check the PWM signal input level selection (5V or 24V short cap) matches your input signal.
- Confirm the input PWM frequency is within the 1KHz-3KHz range.
- Incorrect Output Voltage/Frequency:
- Perform the calibration procedure as described in the "Operating Instructions" section.
- Check the accuracy of your input PWM duty cycle or analog input voltage.
- Ensure the potentiometer has not been accidentally bumped or moved.
- Module Not Functioning:
- Check all wiring for loose connections or incorrect polarity.
- Ensure the power supply voltage is stable and within the specified range.
- Inspect the module for any visible damage.
If problems persist, consult the seller or a qualified electronics technician.
7. User Tips
While no specific user tips were available from reviews or Q&A, here are some general recommendations for working with these modules:
- Always double-check wiring before applying power to prevent damage.
- Use a stable and regulated power supply for optimal performance.
- When calibrating, use a precise multimeter for accurate adjustments.
- Consider using shielded cables for PWM and analog signals in noisy environments to minimize interference.
- For permanent installations, secure the module to prevent accidental disconnections or short circuits.
8. Frequently Asked Questions (FAQ)
No specific frequently asked questions were available. For general inquiries, please refer to the troubleshooting section or contact technical support.
9. Warranty and Support
For information regarding product warranty, technical support, or service, please refer to the seller's policies or contact the TENSTAR ROBOT customer service directly. Keep your purchase receipt for any warranty claims.