TENSTAR ROBOT XH-M603

Contents

XH-M603 Charging Control Module User Manual

Digital LED Display Storage Lithium Battery Charger Control Switch Protection Board

1. Product Overview

The XH-M603 is a charging control module designed for 12-24V storage and lithium batteries. It features a digital LED display for precise voltage monitoring and control, acting as a protection board to manage battery charging cycles.

XH-M603 Charging Control Module top view

Figure 1: Top view of the XH-M603 Charging Control Module, showing terminals, LED display, and control buttons.

2. Specifications

FeatureValue
ModelXH-M603
Input VoltageDC 10-30V
Display Precision0.1V
Control Precision0.1V
Output TypeDirect Output
Voltage Tolerance+/-0.1V
Application Fields12-24V Storage Battery
Dimensions82 x 58 x 18 mm
Package TypeDIP

3. Setup Instructions

Before connecting, ensure all power sources are disconnected. Observe proper polarity to prevent damage to the module or battery.

XH-M603 Charging Control Module angled view with labels

Figure 2: Angled view of the XH-M603 module, highlighting input/output terminals and control buttons.

  1. Power Input Connection: Connect your DC 10-30V power supply to the terminals labeled '+' and '-' on the left side of the module. Ensure correct polarity: '+' to positive, '-' to negative.
  2. Battery Connection: Connect the battery to be charged to the terminals labeled 'BAT+' and 'BAT-' on the left side, below the power input terminals. Ensure correct polarity: 'BAT+' to battery positive, 'BAT-' to battery negative.
  3. Initial Power On: Once connections are secure, apply power to the module. The digital LED display will show the current battery voltage.

4. Operating Instructions

The module features two buttons: one for "Start" (启动) and one for "Stop" (停止), used to configure the charging voltage thresholds.

  1. Setting Starting Voltage:
    • In the normal voltage display state, briefly press the "Start" button. The display will show the currently set start charging voltage.
    • To change this value, long press the "Start" button for 3 seconds. The digital display will flash.
    • While flashing, use the "Start" button to increase the voltage and the "Stop" button to decrease the voltage.
    • Once the desired start voltage is set, wait for a few seconds for the display to stop flashing and save the setting automatically.
  2. Setting Stop Voltage:
    • In the normal voltage display state, briefly press the "Stop" button. The display will show the currently set stop charging voltage.
    • To change this value, long press the "Stop" button for 3 seconds. The digital display will flash.
    • While flashing, use the "Start" button to increase the voltage and the "Stop" button to decrease the voltage.
    • Once the desired stop voltage is set, wait for a few seconds for the display to stop flashing and save the setting automatically.
  3. Factory Reset:
    • To restore the module to its factory default settings, ensure the module is powered on.
    • Simultaneously press and hold both the "Start" and "Stop" buttons.
    • The digital display will show "888", indicating that the factory reset has been performed successfully.

5. Maintenance

  • Keep the module in a dry environment, away from moisture and extreme temperatures.
  • Regularly inspect all wire connections to ensure they are secure and free from corrosion.
  • Clean the module periodically with a soft, dry cloth. Avoid using liquids or abrasive cleaners.
  • Do not attempt to modify the circuit board, as this may void any potential warranty and cause damage.

6. Troubleshooting

  • Module not powering on:
    • Check the input voltage supply (DC 10-30V) and ensure it is within the specified range.
    • Verify that the power input connections ('+' and '-') are correctly wired and secure.
  • Incorrect voltage readings:
    • Ensure the battery connections ('BAT+' and 'BAT-') are secure and have good contact.
    • The module has a voltage tolerance of +/-0.1V. If readings are significantly off, try a factory reset.
  • Battery not charging or not stopping charge:
    • Verify that the start and stop charging voltages are set correctly according to your battery type and desired levels.
    • Ensure the battery itself is functional and capable of accepting a charge.
    • Check all wiring for loose connections or damage.

7. User Tips

  • When setting the stop charging voltage for lead-acid batteries, a common value is around 14V, but always refer to your battery manufacturer's recommendations for optimal charging.
  • For lithium batteries, ensure the set voltages align with the specific cell configuration (e.g., 4.2V per cell for Li-ion).
  • Always set the stop voltage higher than the start voltage to ensure proper charging cycles.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original seller or the manufacturer, TENSTAR ROBOT. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.