1. Introduction

The A-BF RX-680 is a high-performance handheld infrared thermal imager designed for professional temperature measurement and thermal analysis. Featuring a 256x192 pixel IR resolution and a wide temperature range of -20°C to 550°C, this device is suitable for various applications including electrical diagnosis, equipment maintenance, product testing, and HVAC repairing. Its robust design ensures durability for both indoor and outdoor use.

A-BF RX-680 Thermal Imager with key features and example thermal images
Figure 1: A-BF RX-680 Thermal Imager highlighting key features and example thermal images.

2. Setup

2.1 Unpacking

Carefully remove the thermal imager and all accessories from the packaging. Ensure all components listed in the package contents are present:

  • A-BF RX-680 Thermal Imager
  • USB Type-C Charging Cable
  • 16GB SD Card (pre-installed or separate)
  • User Manual (this document)
A-BF RX-680 Thermal Imager with included accessories: USB cable and 16GB SD card
Figure 2: RX-680 Thermal Imager with its standard accessories.

2.2 Charging the Battery

The device is powered by a 3.6V 4500mAh lithium battery. For optimal performance, fully charge the device before first use.

  1. Locate the Type-C charging interface on the device.
  2. Connect the provided USB Type-C cable to the imager and a suitable USB power adapter (not included) or computer USB port.
  3. The charging indicator on the device will show the charging status. A full charge takes approximately 4 hours.
Illustration of Type-C charging interface and battery life
Figure 3: Charging the RX-680 via its Type-C interface. The device offers up to 11 hours of working time on a full charge.

2.3 Inserting/Checking SD Card

The RX-680 uses an SD card for photo storage. Ensure the 16GB SD card is correctly inserted into the designated slot before use.

3. Operating Instructions

3.1 Device Layout and Controls

Familiarize yourself with the buttons and components of the thermal imager:

Detailed front and back view of the A-BF RX-680 with labeled controls and components
Figure 4: Front and back view of the RX-680 with labeled controls.
  • Power Button: Turns the device on/off.
  • Display Screen: 2.8" LCD (320*240) for viewing thermal and visual images.
  • View Memory Button (Gallery): Accesses stored images.
  • LED Button (LED key): Toggles the built-in LED light for dark environments.
  • Navigation Button: Used for menu navigation and selection.
  • Return Button (Escape): Returns to the previous menu or screen.
  • Trigger (Snapshot trigger): Captures thermal images.
  • Infrared Lens: Captures thermal data.
  • Digital Camera (Visible Light Lens): Captures visual light images.

3.2 Powering On/Off

Press and hold the Power Button to turn the device on or off.

3.3 Image Modes

The RX-680 offers four image modes to suit different inspection needs:

  • Thermal Image: Displays only the infrared thermal image.
  • Digital Camera (Visual Light): Displays only the visible light image.
  • PIP (Picture-in-Picture): Overlays a small thermal image onto the visible light image.
  • Fusion: Blends the thermal and visible light images for enhanced detail.
Illustration of the four image modes: PIP, Digital Camera, Thermal Image, and Fusion
Figure 5: The four available image modes for versatile inspection.

3.4 Temperature Measurement and Tracking

The device features auto-tracking for three key measurement points: Hot Spot, Cold Point, and Center Point, providing comprehensive temperature analysis.

Diagram showing 3 Measuring Points with Auto-Tracking: Cold Point, Center Point, Hot Spot
Figure 6: Auto-tracking of Hot Spot, Cold Point, and Center Point for precise temperature readings.

3.5 Adjusting Emissivity

Emissivity is a crucial parameter for accurate temperature measurement. The RX-680 allows for adjustable emissivity to match the surface properties of the object being measured. Refer to the device's menu for adjusting this setting.

3.6 Color Palettes

The imager offers several color palettes to visualize temperature differences effectively:

  • Black Hot
  • White Hot
  • Iron Red
  • Rainbow
  • Rainbow HC
  • Black Hot
  • Yellow Purple

3.7 PC Analysis Software

For advanced analysis and report generation, you can download and use the dedicated PC software. Connect the imager to your computer via the USB Type-C cable to transfer images and utilize the software's features.

Screenshot of the PC Analysis Software interface
Figure 7: The PC analysis software allows for further examination of thermal images and report generation.

4. Maintenance

4.1 Cleaning

To maintain optimal performance and extend the lifespan of your thermal imager:

  • Gently wipe the device body with a soft, dry cloth.
  • For the lens, use a specialized lens cleaning cloth and solution to avoid scratches.
  • Do not use abrasive cleaners or solvents.

4.2 Storage

Store the device in a dry, cool place within the specified storage temperature range of -20°C to +60°C. Avoid extreme temperatures and high humidity.

4.3 Durability

The RX-680 is designed for durability with an IP54 protective grade, offering resistance to dust and splashing water. It is also drop-proof up to 2 meters.

Illustration of the RX-680's durability features: Water Resistance, Dust-proof, and 2m Drop-proof
Figure 8: The RX-680 is built to withstand challenging environments with water resistance, dust-proof design, and 2m drop protection.

5. Troubleshooting

If you encounter issues with your A-BF RX-680, please refer to the following common problems and solutions:

  • Device does not power on: Ensure the battery is fully charged. If the issue persists, contact customer support.
  • Image is blurry or unclear: Check if the lens is clean. Adjust focus if available (RX-680 is focus-free, so this might indicate a different issue).
  • Inaccurate temperature readings: Verify the emissivity setting is correct for the material being measured. Ensure the measurement distance is appropriate.
  • Device freezes or is unresponsive: Try restarting the device by holding the power button. If it continues, contact support.
  • Cannot save images: Check if the SD card is properly inserted and has sufficient free space.

6. Specifications

Detailed technical specifications for the A-BF RX-680 Infrared Thermal Imager:

FeatureSpecification
Brand NameA-BF
ModelRX-680
Temperature Range-20°C ~ 550°C
Accuracy±2°C / ±2% (whichever is greater)
Resolution0.1°C
IR Resolution (Thermal pixels)256 * 192 pixel
Response Wave Band8~14μm
NETD<50mK
Frame Frequency25Hz
FOV (Field of View)56° * 42.2°
IFOV3.8mrad
Display2.8" LCD (320*240)
Display Size2.0 - 3.9 Inches
Color PaletteBlack hot, white hot, iron red, rainbow, rainbow HC, yellow purple
Image ModeThermal image, fusion, PIP, digital camera (visual light)
Charging Time4 Hours
Working Time11 Hours
Working Environment-10°C ~ 50°C, 10~95%RH (non-condensing)
Storage Temperature-20°C ~ 60°C
Protective GradeIP54
Drop-proof2m
Battery3.6V 4500mAh lithium battery
Item Size233 * 70 * 90mm / 9.17 * 2.76 * 3.54in
Item Weight525g / 18.53oz
Is Smart DeviceYes
Power TypeOther (Internal Battery)
High-concerned chemicalNone
OriginMainland China
CertificationCE
Dimensions of the A-BF RX-680 Thermal Imager
Figure 9: Physical dimensions of the RX-680 Thermal Imager.
Illustration of wide temperature range and applications like HVAC and Vehicle Repairing
Figure 10: The RX-680's wide temperature range and diverse application fields.
Collage of main applications for the thermal imager including electric diagnosis, equipment maintenance, and vehicle repairing
Figure 11: Main applications of the A-BF RX-680 Thermal Imager.

7. User Tips

  • Understand Specifications: Pay close attention to the device's specifications, such as temperature range and protective grade (IP54), to ensure it meets your specific application needs.
  • Emissivity is Key: Always adjust the emissivity setting to match the material you are inspecting for the most accurate temperature readings. Different surfaces radiate heat differently.
  • Utilize Image Modes: Experiment with the different image modes (Thermal, Digital Camera, PIP, Fusion) to find the best visualization for your inspection task. Fusion mode can often provide a clearer context by blending thermal and visual details.
  • Regular Charging: To ensure the device is always ready for use, charge it regularly, especially before critical inspections. The 11-hour working time is substantial, but a fully charged battery is always recommended.

8. Warranty and Support

A-BF is committed to providing quality products and customer satisfaction. If you encounter any issues with your RX-680 Thermal Imager, please contact our customer service team. Our professional after-sales personnel and technical staff are ready to assist you with solutions and support.

For assistance, please reach out to the A-BF Official Store customer service.