GEYA GPS8 Voltage / Current Protector

Contents

GEYA GPS8 Din Rail Protective Device Instruction Manual

Model: GPS8 Voltage / Current Protector

1. Product Overview

The GEYA GPS8 series is a Din Rail mounted protective device designed to safeguard household electrical equipment from overvoltage, undervoltage, and overcurrent conditions. It features true RMS measurement, a digital display for real-time voltage and current values, and LED indicators for fault status. The device is available in two main function types:

  • GPS8-01: Provides Overvoltage and Undervoltage Protection.
  • GPS8-02: Provides Over Current, Overvoltage, and Undervoltage Protection.

It incorporates a double bus wiring design for enhanced reliability and allows for user-defined settings for protection values and delays.

GEYA GPS8-02 Protective Device showing digital display for voltage and current, and indicators for over/under voltage and over current.

Figure 1: GEYA GPS8-02 Protective Device with digital display and indicators.

2. Technical Specifications

ParameterSpecification (GPS8-02)
FunctionOver voltage, under voltage and over current
Rated supply voltageAC220V (L-N)
Rated supply frequency45~65Hz
Operation voltage range80V~400V (L-N)
Rated operational current32A, 40A, 50A, 63A, 80A (AC1)
BurdenAC max. 3VA
Over voltage operation valueOFF, 230V~300V
Under voltage operation value140V~210V, OFF
Over/under voltage action delay0.1s~10s
Over current operation value1~32A, 40A, 50A, 63A, 80A
Over current action delay2s~600s
Power-up delay2s~600s
Reset time2s~900s
Measurement error<1%
Electrical life (AC1)1×104
Mechanical life1×106
Operating temperature-20°C~+60°C
Storage temperature-35°C~+75°C
Mounting/DIN railDin rail EN/IEC 60715
Protection degreeIP40 for front panel/IP20 terminals
Operating positionAny
Overvoltage categoryIII.
Pollution degree2
Dimensions82×36×68mm
Weight135g
Diagram showing the dimensions of the GEYA GPS8 protective device.

Figure 2: Device Dimensions.

3. Installation and Wiring

The GEYA GPS8 protective device is designed for DIN rail mounting (EN/IEC 60715). Installation should only be performed by qualified electricians to ensure compliance with appropriate safety standards.

3.1 Wiring Diagram

The device supports two incoming line modes: Upper Incoming Line and Down Incoming Line. Refer to the diagrams below for correct wiring.

Wiring diagrams for GPS8-02-U (Upper Incoming Line) and GPS8-02-D (Down Incoming Line).

Figure 3: Wiring Diagrams for Upper and Down Incoming Lines.

NOTE: This product does not have an isolation function. Always disconnect the superior Miniature Circuit Breaker (MCB) during maintenance to prevent electric shock.

3.2 Example Wiring

An example of connecting multiple GPS8-02 units with MCBs and loads is shown below.

Example wiring diagram showing multiple GPS8-02 units connected with MCBs and loads.

Figure 4: Example Wiring for Multiple Devices.

4. Operating Instructions

4.1 Panel Diagram and Indicators

Panel diagram of the GPS8 device showing the digital display, indicators for over voltage, under voltage, over current, and buttons for setting, increasing value, and power on/off.

Figure 5: Device Panel Diagram.

The panel features a dual digital display for voltage (V) and current (A), along with LED indicators:

  • >U: Over voltage indicator
  • <U: Under voltage indicator
  • >I: Over current indicator
  • Power open and close indicator: Indicates load status.

Buttons:

  • M (Setting Key): Press and hold for 3 seconds to enter/save settings.
  • ▲ (Up Arrow): Used to increase parameter values.
  • Power Button: Used to decrease parameter values. After exiting settings, it can manually turn the load on or off. If automatic fault reset is off, this button can be used for manual reset after a fault.

4.2 Parameter Setting

To adjust the protection parameters:

  1. Press and hold the M (Setting) key for 3 seconds to enter the setting mode.
  2. Use the ▲ (Up Arrow) and Power Button (Down Arrow) to adjust the desired parameter value.
  3. Press and hold the M key for 3 seconds again to save the settings and exit.
  4. If no operation is performed for 60 seconds in setting mode, the device will automatically exit without saving changes.

Parameter Setting Table (Factory Defaults):

ParameterRangeStep valueFactory settings
Over voltage valueOFF, 230V~300V1V275V
Over voltage recovery value225V~295V1V265V
Under voltage value140V~210V, OFF1V175V
Under voltage recovery value145V~215V1V180V
Voltage fault action time0.1s~10s0.1s0.5s
Over current valueOFF, 1A~32/40/50/63A0.1A32A/40A/50A/63A
Over current action delay2s~600s1s5s
Power on delay time2s~600s1s5s
Reset time2s~900s1s30s
Fault resetON-OFF—ON

4.3 Manual Operation

In normal operation, the load can be switched on or off manually by pressing the Power button for 0.5 seconds.

4.4 Power-on and Reset Delay

During power-on or after a fault, the device will display a countdown according to the set delay time before entering the running state.

5. Maintenance and Troubleshooting

The GEYA GPS8 protective device is designed for reliable operation with minimal maintenance. Regular visual inspection for any physical damage or loose connections is recommended.

WARNING: Always disconnect power from the superior MCB before performing any maintenance or inspection on the device.

5.1 Troubleshooting

  • Device not powering on: Check the incoming power supply and ensure connections are secure.
  • Device trips frequently: Review the set overvoltage, undervoltage, and overcurrent parameters. Ensure they are appropriate for your connected load and supply conditions. Check for actual faults in the electrical system.
  • Display not working: Verify power supply. If power is present and the display remains off, contact support.

6. User Tips

  • Parameter Adjustment: Take your time when adjusting parameters. A short press of the up/down buttons changes values incrementally, while a long press allows for faster adjustment. Remember to save your settings by holding the 'M' button.
  • Reliability: Users have noted the consistent quality and reliability of GEYA products. Proper installation and adherence to specifications will ensure long-term performance.
  • Value for Money: This product is considered a good investment for its protective capabilities and quality.

7. Environmental Disposal

All electrical waste should be disposed of in compliance with current WEEE (Waste Electrical and Electronic Equipment) regulations. Do not dispose of this product with general household waste.

8. Manufacturer Information and Support

GEYA ELECTRICAL CO.,LTD

Address: Wenzhou Bridge Industrial Zone, Beibaixiang Town, Yueqing, Zhejiang, China 325603

Email: sale@cngeya.com

Website: www.geya.net

For further assistance or inquiries, please contact GEYA directly via the provided contact information.

A user manual in PDF format is available for download from the manufacturer's website: GEYA GPS8 User Manual (PDF)

8.1 GEYA Company Overview Video

Watch this video for an overview of GEYA's manufacturing processes and commitment to quality.

Video 1: GEYA Company Introduction and Manufacturing Process.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.