1. Introduction
The XY5008L is a digital controlled DC regulated power supply module designed for constant voltage and constant current applications. It features a new architecture with synchronous rectification, offering a typical efficiency of 95%. This module provides precise control over output voltage and current, making it suitable for maintenance, CNC applications, and various electronic projects. It incorporates comprehensive software and hardware protection mechanisms for stable and reliable performance.

2. Safety Warnings
- Read all instructions before use to ensure safety and prevent damage.
- Warning: Keep the device and its cord out of reach of children under 3 years old.
- This product is a DC step-down digital controlled stabilized power supply. The input voltage must be higher than the output voltage (pressure difference > 0.05% + 1V).
- Do not connect the device to AC power.
- Do not use an input voltage that exceeds the specified range (6.0-55.0V).
- Ensure proper ventilation during operation, especially when drawing high power.
3. Product Overview
3.1. Physical Dimensions
The module is compact, designed for easy integration into various setups. Below are the dimensions and recommended opening size for panel mounting.

3.2. Internal Components and Connections
The module features a robust design with key components for efficient power conversion and heat dissipation. The input and output terminals are clearly marked for easy connection.

- 15A Sendust Magnetic Ring Inductor: For stable current regulation.
- Intelligent Temperature Control Fan: Automatically activates when temperature exceeds 50°C or current exceeds 2A to ensure optimal cooling.
- Thickened Heat Sink: Enhances heat dissipation.
- Pluggable Terminal Block: For secure and convenient input/output connections.
4. Technical Specifications
| Feature | Specification |
|---|---|
| Input Voltage | 6.0V - 55.0V |
| Output Voltage | 0.0V - 50.0V |
| Output Current | 0.0A - 8.10A |
| Output Power | 0W - 400W |
| Typical Efficiency | 95% |
| Voltage Resolution | 0.01V |
| Current Resolution | 0.001A |
| Voltage Accuracy | ±0.4% + 1 word |
| Current Accuracy | ±0.5% + 3 words |
| Capacity Measurement | 0-99999Ah |
| Energy Measurement | 0-99999Wh |
| Time Measurement | 0-1000 hours |
4.1. Protection Mechanisms
- Hardware Protection: Input anti-reverse connection protection, output short-circuit protection (short circuit does not burn).
- Software Protection:
- Over Voltage Protection (OVP)
- Over Current Protection (OCP)
- Over Power Protection (OPP)
- Over Temperature Protection (OTP)
- Input Under Voltage Protection (LVP)
5. Setup and Installation
Before connecting the module, ensure all power sources are disconnected. Refer to Figure 3 for the terminal layout.
- Identify the input terminals:
VIN+(Input voltage positive) andVIN-(Input voltage negative). - Identify the output terminals:
OUT+(Output voltage positive) andOUT-(Output voltage negative). - Connect your DC input power source to the
VIN+andVIN-terminals. Ensure the input voltage is within the 6.0V-55.0V range and is at least 1V higher than your desired output voltage. - Connect your load to the
OUT+andOUT-terminals. - Double-check all connections for polarity and security before applying power.
6. Operation
6.1. Basic Controls
- ON/OFF Button: Press and hold for 3 seconds to power the device ON or OFF.
- Encoder Button (Rotary Knob): Used for setting parameters and cycling through display modes.
6.2. Setting Voltage and Current

- Set Voltage: Short press the encoder button. The "CV" indicator will flash, and the voltage value will be selectable. Rotate the encoder to adjust the voltage (clockwise to increase, counter-clockwise to decrease).
- Set Current: Long press the encoder button for one second. The "CC" indicator will flash, and the current value will be selectable. Rotate the encoder to adjust the current (clockwise to increase, counter-clockwise to decrease).
- After setting, the device will automatically exit the setting mode if no operation is performed within 3 seconds.
6.3. Display Modes
- OFF State Display: When the device is OFF, the LCD will display the set voltage and current, providing a clear and intuitive overview of the configured parameters.
- ON State Display Switching: In the ON state, long press the ON/OFF button for 2 seconds to switch between displaying input voltage/current and output voltage/current.
- Browsing Function: Short press the encoder button to cycle through various display functions (current A, power W, capacity Ah, energy Wh, time h).

6.4. Locking Function
To prevent accidental changes to the set voltage and current, the module includes a locking function.

- Lock: Long press the encoder button for 5 seconds to lock the set voltage and current.
- Unlock: After locking, long press the encoder button for 5 seconds again to unlock.
6.5. Protection Parameter Settings
The module allows configuration of various protection thresholds:
- Input Undervoltage Protection (LVP): Default 4.8V.
- Overvoltage Protection (OVP): Default 52.00V.
- Overcurrent Protection (OCP): Default 8.20A.
- Over Power Protection (OPP): Default 410W.
- Maximum Capacity (OAH): Set the maximum output capacity in Ah.
- Maximum Energy (OPH): Set the maximum output energy in Wh.
- Boot Status: Configure whether the device powers ON or OFF by default after power-on.
- Default Parameters: You can set the default parameters (Constant Voltage CV or Constant Current CC) by pressing the encoder button.
6.6. Product Demonstration Video
Watch this video for a visual guide on the product's features and basic operation.
7. Maintenance and Storage
7.1. Cleaning
- Always turn off the equipment and disconnect all power sources before cleaning.
- Use a soft, dry cloth to wipe the exterior of the device. Do not use liquid cleaners or solvents.
7.2. Storage
- Store the device in a normal environment, away from extreme temperatures and humidity.
- Avoid prolonged exposure to direct sunlight.
- Store in a dry, dust-free environment.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | No input power, incorrect wiring, or input voltage outside range. | Check input power connection and polarity. Verify input voltage is within 6.0V-55.0V. Ensure ON/OFF button is pressed for 3 seconds. |
| No output voltage/current. | Output is OFF, protection triggered (OVP, OCP, OPP, OTP, LVP), or input voltage is too low. | Ensure the device is ON. Check protection settings and reset if necessary. Verify input voltage is at least 1V higher than the set output voltage. Check output wiring. |
| Output is unstable or fluctuates. | Poor connections, excessive load, or input power instability. | Secure all wiring connections. Reduce load if it exceeds module's capacity. Ensure input power source is stable. |
| Fan runs continuously or frequently. | High internal temperature or high output current. | This is normal operation if temperature > 50°C or current > 2A. Ensure adequate airflow around the module. |
9. User Tips
- Always ensure your input power source can provide sufficient current for your desired output power.
- When setting voltage and current, it's good practice to set the voltage first, then the current limit, especially when connecting to sensitive loads.
- Regularly check connections for tightness to prevent intermittent power delivery or arcing.
- If the fan frequently activates, consider improving the ventilation around the module or reducing the load to prevent overheating.
10. Disposal and Recycling
According to the WEEE Directive (2012/19/EU), electronic waste must be recycled at appropriate collection points to prevent potential negative impacts on the environment and human health. Do not dispose of this product with unsorted municipal waste.
11. Compliance Information
This product complies with the following certifications:
- CE (Conformité Européenne)
- RoHS (Restriction of Hazardous Substances)
- UKCA (UK Conformity Assessed)
12. Further Support
For more detailed information or advanced configurations, please refer to the official user manual PDF:
Manufacturer: Shenzhen yuandong zhicheng technology co., ltd
Address: 6c14 rainbow building no. 3002, caitian south road, gangxi community, futian street, futian street, shenzhen city, guangdong province
Contact: 86-86-15767985835