Hantek DSO2D15, DSO2C10, DSO2D10, DSO2C15

Contents

Hantek Digital Oscilloscope DSO2000 Series User Manual

Models: DSO2D15, DSO2C10, DSO2D10, DSO2C15

1. Introduction

This manual provides essential information for the safe and effective operation of your Hantek DSO2000 series Digital Oscilloscope. The DSO2000 series includes models DSO2D15, DSO2C10, DSO2D10, and DSO2C15, offering 2 channels with bandwidths of 100MHz or 150MHz and a real-time sampling rate of 1GSa/s. Please read this manual thoroughly before using the device.

Hantek Digital Oscilloscope Front View
Figure 1: Hantek Digital Oscilloscope Front View

2. Setup

2.1 Unpacking and Inspection

Carefully remove the oscilloscope from its packaging. Inspect the device for any signs of damage during transit. Ensure all accessories, including power adapter and probes, are present.

2.2 Power Connection

Connect the provided power adapter to the power input on the rear panel of the oscilloscope. Plug the adapter into a suitable AC power outlet (100-240V, 50/60Hz). The device is designed for mains power operation and does not feature a demountable battery.

Rear Panel and Power Connection
Figure 2: Rear Panel with Power Input and USB Port

2.3 Probe Connection

Connect the oscilloscope probes to the CH1 and CH2 analog signal input channels on the front panel. Ensure a secure connection. Typically, one 1:10 probe is included with the device, rated for the oscilloscope's bandwidth (e.g., 150MHz for DSO2D15).

2.4 Front Panel Overview

Front Panel Controls and Connectors
Figure 3: Labeled Front Panel Controls

The front panel features:

  • Retractable Handle: For portability.
  • Options Buttons (F1-F6): Context-sensitive menu controls.
  • Common Function Area: Buttons for Menu, Recall, Measure, Acquire, Utility, Cursor, Display, Save to USB, Decode, Help.
  • Executive Control: Knobs and buttons for general settings.
  • USB Port: For data transfer and storage.
  • Analog Signal Input Channels (CH1, CH2): BNC connectors for probes.
  • External Trigger Input Channel (EXTTRIG/GENOUT): For external trigger signals or function generator output (on AFG models).
  • Probe Original: Probe compensation output.
  • Trigger Control: Knobs and buttons for trigger settings.
  • Power Switch: To turn the device on/off.

3. Operating Instructions

3.1 Basic Operation

  1. Power On: Press the power switch on the front panel.
  2. Probe Compensation: Before taking measurements, connect a probe to CH1 and the probe compensation output. Adjust the probe until a stable square wave is displayed.
  3. Vertical Controls: Use the VOLTS/DIV knobs to adjust the vertical scale (voltage per division) for each channel. Use the POSITION knobs to shift the waveform vertically.
  4. Horizontal Controls: Use the SEC/DIV knob to adjust the horizontal scale (time per division). Use the POSITION knob to shift the waveform horizontally.
  5. Trigger Control: Adjust the TRIGGER LEVEL knob to stabilize the waveform display. Use the TRIGGER MENU button to access advanced trigger settings (Edge, Pulse, Video, Slope, etc.).

3.2 Waveform Acquisition and Measurement

  • Acquire Menu: Press the ACQUIRE button to set acquisition mode (Normal, Peak Detect, Average) and record length.
  • Measure Menu: Press the MEASURE button to display automatic measurements such as Vpp, Vmax, Vmin, Freq, Period, etc.
  • Cursor Menu: Use the CURSOR button to activate manual cursors for precise voltage and time measurements.

3.3 Advanced Features

  • Decode Function: The oscilloscope supports various serial bus decoding (e.g., UART, CAN, LIN). Access this via the DECODE button. Refer to the on-screen menu for specific protocol settings.
  • Function Generator (AFG Models): Models with 'D' in their name (e.g., DSO2D15) include an Arbitrary Function Generator. The output is available via the EXTTRIG/GENOUT BNC connector. This allows simultaneous use of the oscilloscope and the generator.
  • USB Storage: Use the SAVE TO USB button to save waveforms, setups, or screen captures to a USB flash drive connected to the front panel USB port.
Video 1: Hantek Oscilloscope Product Overview (demonstrates features and interface)

4. Maintenance

4.1 Cleaning

To clean the oscilloscope, use a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the casing or screen. Ensure the device is powered off and disconnected from the mains before cleaning.

4.2 Safety Warnings

WARNING: Hazardous voltage inside. Do not remove the cover unless by specified personnel. There are no user-serviceable parts inside. Refer all servicing to qualified service personnel.

Ensure proper grounding when connecting probes to circuits. Improper grounding can lead to short circuits or damage to the device and connected equipment.

5. Troubleshooting

  • No Display/Power: Check the power cable connection and the power outlet. Ensure the power switch is in the 'ON' position.
  • Unstable Waveform: Adjust the trigger level and trigger mode. Ensure probes are properly compensated.
  • No Signal on Screen: Verify probe connections to both the oscilloscope and the circuit under test. Check the VOLTS/DIV setting; the signal might be outside the current vertical range.
  • Short Circuit when Connecting Probe: Always ensure proper grounding of the oscilloscope and the circuit being tested. Connect the probe ground clip to the circuit's ground reference before connecting the probe tip. Avoid connecting the oscilloscope ground to a live voltage source.
  • Limited Signal Recording: The device has 8M points of record length. For capturing longer signals, consider adjusting the time base (SEC/DIV) or utilizing the USB storage feature to save and analyze data externally.
  • Device Malfunctions/Bugs: If the device exhibits unexpected behavior, try restarting it. If issues persist, consult the manufacturer's support resources.

6. Specifications

FeatureSpecification
BrandHantek
Model NumbersDSO2D15, DSO2C10, DSO2D10, DSO2C15
Bandwidth100MHz (DSO2C10/DSO2D10), 150MHz (DSO2C15/DSO2D15)
Digital Channels2
Real Time Sampling Rate1GSa/S
Max Waveform Capture Rate30,000wfm/s
Record Length8M points
Display Resolution800*480 Pixels
Display Size7 Inches
Power Input100-240V, 50/60Hz, 50 Watts MAX
BatteryNot demountable (Mains powered only)
CertificationCE
Dimensions (L x W x H)318mm x 140mm x 150mm (approx.)
Weight2.8 kg (approx.)

7. User Tips

  • Grounding Safety: Always double-check your grounding connections. Incorrect grounding can lead to unexpected short circuits and potential damage to the oscilloscope or the circuit under test.
  • Probe Selection: While one 1:10 probe is typically included, consider acquiring additional probes if you frequently work with two channels or require different attenuation ratios.
  • Signal Recording: If you need to capture signals longer than the internal memory allows, utilize the USB port to save data to an external drive for later analysis on a computer.
  • Thermal Management: For prolonged high-performance use, some users suggest considering additional passive cooling (e.g., small heatsinks) for internal chips, though this should only be attempted by qualified personnel due to warranty and safety implications.
  • AFG Functionality: If you have a 'D' model (e.g., DSO2D15) with the Arbitrary Function Generator, remember that it can be used simultaneously with the oscilloscope channels, providing a versatile test setup.

8. Warranty and Support

Your Hantek Digital Oscilloscope is covered by a manufacturer's warranty. For warranty claims, technical support, or service, please contact your original point of purchase or the official Hantek support channels. Keep your purchase receipt as proof of purchase.

The device is CE certified, indicating compliance with European health, safety, and environmental protection standards.