Kamoer UIP WIFI V2

Kamoer UIP WIFI V2 Peristaltic Pump User Manual

Model: UIP WIFI V2 | Brand: Kamoer

1. Introduction

The Kamoer UIP WIFI V2 Peristaltic Pump is an intelligent, high-precision fluid transfer device designed for various laboratory and industrial applications. Featuring a stepper motor, adjustable flow rate, quick tube change support, and multiple control interfaces (WIFI, RS485, Analog, Foot Switch), it offers reliable and precise fluid handling. This manual provides essential information for the safe and efficient operation and maintenance of your pump.

Kamoer UIP WIFI V2 Peristaltic Pump with digital display

Figure 1: Kamoer UIP WIFI V2 Peristaltic Pump

2. Safety Information

Please read and understand all safety instructions before operating the pump. Failure to do so may result in injury or damage to the equipment.

  • Ensure the power supply matches the pump's requirements (AC 100-240V).
  • Do not operate the pump with damaged power cords or tubing.
  • Always wear appropriate personal protective equipment (PPE) when handling chemicals or liquids.
  • Avoid immersing the pump in water or other liquids.
  • Disconnect power before performing any maintenance or tube changes.
  • Ensure proper ventilation when operating in enclosed spaces.
  • Keep the pump away from heat sources and direct sunlight.

3. Package Contents

Verify that all items listed below are included in your package:

  • 1 × UIP WIFI V2 Peristaltic Pump
  • 1 × Power cable
  • 1 × Foot switch
  • 1 × Quick junction terminal
  • 1 × Silicone tube
  • 1 × Screwdriver (for foot switch connection)
Standard fittings included with the Kamoer Peristaltic Pump

Figure 2: Standard Fittings

4. Specifications

Attribute Value
Model Number UIP WIFI V2
Brand Name Kamoer
Power Source Electric (AC 100-240 V)
Motor Type Stepper Motor
Theory Rotary Pump
Structure Peristaltic Pump
Pressure Low Pressure
Standard or Nonstandard Standard
WIFI Control Only for Firmware Upgrade
UI Interface Touch screen
Lifetime More than 6000H
Number of Rotors 3 rotors or 6 rotors
Pump Head Single Head / Double Head
Temperature 0~40℃
Humidity 0~80℃
Size 140*231*180mm
Net Weight 4.8KG Double head, 4.3KG Single head
Origin China Mainland
Certification CE, RoHS

Flow Rate Specifications

Pump Head Tube ID:OD Speed Range (RPM) Flow Rate (ml/min) Tubing Lifetime Tubing Working Temperature
KK1800 1.6mm 3 rotors 19#(2.4*5.6), 16#(3.2*6.4), 25#(4.8*8.0), 17#(6.4*9.6), 18#(7.9*11.1) 0.1-350 0.1-1500 Silicone 200H -60℃~200℃
KK1800 1.6mm 6 rotors 19#(2.4*5.6), 16#(3.2*6.4), 25#(4.8*8.0), 17#(6.4*9.6), 18#(7.9*11.1) 0.1-350 0.1-750 Silicone 200H -60℃~200℃
KK1800-T2.5 2.5mm 3 rotors 15#(4.8*9.8), 24#(6.4*11.4) 0.1-350 0.5-950 Silicone 200H -60℃~200℃

5. Setup

5.1. Connecting the Power

  1. Ensure the pump is placed on a stable, level surface.
  2. Locate the power interface (2) and power switch (1) on the back of the pump.
  3. Connect the provided power cable to the power interface on the pump and then to a suitable AC 100-240V power outlet.
  4. Turn on the pump using the power switch (1). The screen should illuminate.
Back panel of Kamoer pump showing power switch, power interface, Interface A and Interface B

Figure 3: Rear Panel Interfaces

5.2. Connecting the Pump Tube

  1. Open the pump head by lifting the latch or turning the knob (refer to Figure 4).
  2. Carefully insert the silicone tube into the pump head, ensuring it is properly seated in the rollers.
  3. Close the pump head securely.
Close-up of pump head showing open and closed positions for tube replacement

Figure 4: Pump Head Open and Close Mechanism

5.3. Connecting the Foot Switch

The foot switch provides convenient hands-free operation.

  1. Take out one of the quick junction terminals from the package.
  2. Connect the orange wire of the foot switch to the 'Pedal' pin (pin 11) on Interface B.
  3. Connect the yellow wire of the foot switch to the 'Common terminal' pin (pin 12) on Interface B.
  4. Use the provided screwdriver to tighten the screws on the terminal to secure the wires.
  5. Plug the quick junction terminal into Interface B on the back of the pump.
  6. On the pump's touch screen, navigate to System > Pedal.
  7. Toggle the 'ON' switch to enable pedal control.
  8. Select the desired trigger type (e.g., Falling edge trigger).
Diagram of Interface A and Interface B pinouts with foot pedal control highlighted

Figure 5: Interface B Pinout for Foot Switch

6. Operating Instructions

The UIP WIFI V2 pump offers various operating modes and calibration features via its touch screen interface.

Video 1: Kamoer Peristaltic Pump Operation Demonstration

6.1. Flow Rate Calibration

Accurate calibration ensures precise fluid dispensing.

  1. From the main screen, navigate to the Calibration tab.
  2. Click the Fill button to fill the pump tube with the liquid.
  3. Once the tube is filled, click Stop.
  4. Empty the measuring cylinder or beaker.
  5. Click the Calibrate button. The pump will run for a default time (e.g., 60 seconds at 100 RPM).
  6. Once the calibration time ends and the pump automatically stops, measure the volume of liquid dispensed into the cylinder.
  7. Input the measured liquid volume into the pump's interface.
  8. Click Done to complete the calibration.

6.2. Continuity Mode

Continuity mode allows for continuous fluid transfer at a set flow rate.

  1. From the main screen, click on Mode.
  2. Select Continuity from the running mode options.
  3. Adjust the desired flow rate using the + and - buttons, or click on Flow Rate (ml/min) to enter the value directly.
  4. Click Start to begin continuous pumping.

6.3. Ration Mode

Ration mode allows for dispensing specific volumes of liquid with customizable parameters.

  1. From the main screen, click on Mode.
  2. Select Ration from the running mode options.
  3. Click Edit to set the allocation parameters:
    • Volume (ml): Set the volume to dispense per cycle.
    • Flow Rate (ml/min): Set the flow rate for dispensing.
    • Pause Time (s): Set the pause duration between cycles.
    • Count: Set the number of dispensing cycles.
    • Cycle Mode: Choose between Auto or Semi-Auto.
  4. Adjust parameters according to your requirements.
  5. Click Start to begin the programmed dispensing cycles.
Kamoer pump touch screen interface showing various modes and settings

Figure 6: Touch Screen Interface

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your Kamoer Peristaltic Pump.

7.1. Tube Replacement

Peristaltic pump tubes are wear-and-tear parts and should be replaced regularly depending on usage and liquid type. Refer to the 'Connecting the Pump Tube' section for instructions on how to open the pump head and replace the tube.

7.2. Cleaning

  • Wipe the exterior of the pump with a soft, damp cloth.
  • Do not use abrasive cleaners or solvents.
  • Ensure no liquid enters the internal components of the pump.
  • Clean the pump head and rollers regularly to prevent residue buildup.

7.3. Storage

When not in use, store the pump in a clean, dry, and cool environment, away from direct sunlight and corrosive substances.

8. Troubleshooting

If you encounter issues with your pump, refer to the following common problems and solutions:

Problem Possible Cause Solution
Pump does not turn on No power, power cable loose, power switch off Check power connection, ensure power switch is ON.
No fluid flow or inconsistent flow Pump tube kinked, incorrect tube size, pump head not closed properly, calibration error Check tube for kinks, ensure correct tube size is used, verify pump head is securely closed, re-calibrate flow rate.
Pump making unusual noise Worn out tube, foreign object in pump head, motor issue Replace pump tube, inspect pump head for obstructions, contact support if noise persists.
Touch screen unresponsive Temporary software glitch, power issue Restart the pump. If issue persists, contact support.

9. User Tips

  • Tubing Selection: If your liquid is viscous or corrosive, it is recommended to choose BPT tubing for better chemical stability and longer life. Silicone tubing is generally suitable for neutral liquids.
  • Regular Calibration: For applications requiring high precision, perform flow rate calibration regularly, especially after changing tubing or if there are significant changes in liquid properties.
  • Prevent Kinks: Always ensure the tubing is installed without any kinks or sharp bends to maintain consistent flow and prevent damage to the tube.
  • Interface B: Interface B supports current analog, direction, and foot control. This allows for flexible integration into automated systems or for hands-free operation.

10. Warranty and Support

For any technical assistance, warranty claims, or further inquiries, please contact the Kamoer Global Store customer support. Ensure you have your product model and purchase details ready when contacting support.

Related Documents - UIP WIFI V2

Preview Kamoer UIP WIFI E Smart Peristaltic Pump User Manual
Comprehensive user manual for the Kamoer UIP WIFI E Smart Peristaltic Pump, detailing its features, operation modes (Continuity, Ration, Remote), system settings, maintenance, and technical specifications.
Preview Kamoer UIP WIFI E Smart Peristaltic Pump: Quick Start Guide and Technical Specifications
Quick start guide and technical specifications for the Kamoer UIP WIFI E Smart Peristaltic Pump, detailing its features, interface, app connectivity, and warranty information.
Preview Kamoer KPHM100 Micro Peristaltic Pump Product Manual
Comprehensive product manual for the Kamoer KPHM100 micro peristaltic pump. Details features, specifications for brushed DC, brushless DC, and stepper motor variants, applications, pump tube information, and optional accessories. Includes model explanation and technical data.
Preview Kamoer M1-STP Smart Peristaltic Pump Product Manual
This manual provides detailed information on the Kamoer M1-STP Smart Peristaltic Pump, including its features, specifications, model definitions, interface explanations, and accessories. It covers performance characteristics and typical applications in laboratory and industrial settings.
Preview KCP-KK300-D Adjustable Peristaltic Pump User Manual
User manual for the Kamoer KCP-KK300-D adjustable peristaltic pump, detailing its features, specifications, operating conditions, interface description, and safety precautions.
Preview Kamoer AIP WIFI Smart Peristaltic Pump Quick Start Guide | Operation and Features
Get started with your Kamoer AIP WIFI smart peristaltic pump. This guide covers setup, operation, connectivity options (Wi-Fi, analog, RS485, CAN), technical specifications, and warranty information.