1. Introduction
This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of your HLTNC 2.2kW ER20 Square Air Cooled Spindle Motor and Variable Frequency Drive (VFD) Kit. Please read this manual thoroughly before using the product to ensure safe and efficient operation.
The kit typically includes:
- 2.2kW Spindle Motor
- 2.2kW Inverter (HY or YL620/YL620-A model)
- ER20 Collet Set (1-13mm)
For a comprehensive PDF version of the user manual, please refer to the User Manual (PDF).
2. Safety Precautions
WARNING: High voltage inside. Maintenance should only be performed by well-trained personnel.
2.1 General Safety Guidelines
- Always ensure the power supply is disconnected before performing any installation, wiring, or maintenance.
- Verify that the ordered specifications match the nameplate (Working voltage and KVA number).
- Check for any damage or deformation to the unit during transportation.
- Ensure all internal assembly parts, wiring, and circuit boards are free from abnormalities.
- Confirm all terminals are locked tightly and there is no foreign matter in the machine.
- Verify that all buttons on the operator panel function normally.
- Ensure all additional accessories are present.
2.2 Installation Location and Environment
- Temperature: Operate within an ambient temperature range of -5°C to 40°C.
- Humidity: Avoid places with dripping water and high humidity.
- Exposure: Do not install in direct sunlight, high temperature, or severe dust environments.
- Corrosion: Keep away from corrosive gases and liquids.
- Cleanliness: Ensure the area is free from excessive dust, oil, and metal particles.
- Vibration: Install in a location free from vibration to facilitate easy maintenance and inspection.
- Noise: Avoid areas with electromagnetic noise interference.
- Ventilation: Install the inverter vertically to ensure good air circulation and sufficient space around it for cooling and maintenance.
- Mounting: If the installation surface is not secure, place a flat plate under the inverter's base. Loose mounting can stress and damage main circuit parts. The installation wall should be made of non-combustible materials like iron plates.
- Multiple Inverters: When installing multiple inverters in the same cabinet, ensure proper spacing and add a baffle plate in the middle.
2.3 Braking Resistor Safety
- The installation of a braking resistor must consider environmental safety and flammability. Maintain a distance of at least 100mm from the inverter.
- If you need to change the resistance and power of the braking resistor, contact your local dealer.
- Braking resistors must be ordered separately if needed.
- For machinery with large inertia, increase the capacity of the braking resistor. Contact your local dealer for details.
3. Specifications
3.1 Spindle Motor Specifications
| Attribute | Value |
|---|---|
| Brand Name | HLTNC |
| Model Number | 2.2KW Air Cooled Spindle |
| Drive | Motor |
| Maximum Torque | 1.17Nm |
| Operating Speed | 24000rpm |
| Application | Milling |
| Voltage Options | 110V/220V/380V |
| Collet Type | ER20 |
| Spindle Frequency | 300Hz/400Hz |
| Certification | CE |
| Origin | Mainland China |
| Runout off | less than 0.005mm |
| Lubrication | Grease Lubrication |
3.2 VFD (Variable Frequency Drive) Specifications
| Attribute | Value |
|---|---|
| Type | 2.2kW/220V/380V (YL620-A or HY) |
| Input Voltage | AC 220V (+/-15%) |
| Input Frequency | 50/60Hz (48-63Hz) |
| Input Phase | 1 or 3 phase |
| Output Voltage | AC 220V |
| Output Current | 10A |
| Output Frequency | 0-400Hz |
| Output Phase | 3 phase |
| Control Method | V/F control; Open-loop flux vector control |
| Warranty | 1 year from the date purchased |
3.3 Product Dimensions and Weight
| Component | Dimensions (L x W x H) | Weight |
|---|---|---|
| Spindle Motor (approx.) | 272mm x 80mm x 110mm | ~1.5KG |
| VFD (approx.) | 160mm x 122mm x 170mm | ~1.5KG |
| Package | 40cm x 33cm x 20cm | 7.8KG |
The factory default setting of YL inverter is 400Hz, no need to set it, it is suitable for our spindle motor.


4. Setup and Installation
4.1 Unboxing and Inspection
Upon receiving your kit, carefully unbox all components. Check the contents against the packing list and inspect for any visible damage. Ensure the product manual is present.
4.2 Spindle Motor Components

4.3 VFD Digital Operator Panel Description

4.4 Collet Replacement
The ER20 chuck is compatible with 99% standard cutting tools. Follow these steps to replace collets:
- Loosen the collet nut using a wrench.
- Remove the old collet and insert the new one.
- Tighten the collet nut securely.


5. Wiring Diagram and Connections
Correct wiring is crucial for safe and proper operation. Ensure all connections are tight and secure.
5.1 Main Circuit Terminal Description (VFD)
| Symbol | Function Description |
|---|---|
| R S T | Input terminal of AC line power. (220V class, for both single/three phase, single phase connected to any two phases) |
| U V W | Output terminal of the inverter to the spindle motor. |
| P+ Pr | Connector for braking resistor (optional) |
| E | Ground terminal: the third method of grounding for 220V and special grounding for 380V of electrical engineering regulations. |
5.2 Control Terminal Description (VFD)
| Terminal Symbol | Description |
|---|---|
| NC | NOTCONNECTED |
| MO | Triode output |
| FWD | Forward |
| REV | Reverse |
| X1, X2, X3, X4 | Multi-function input 1-4 |
| XGND | Common terminal of digital control signal |
| XVCC | External input 15V |
| GND | Analog control signal common terminal |
| VI1 | Analog current frequency command |
| 10V | Power supply for speed setting |
| 13V | External power supply |
| AO | Analog output |
| NC1 | Relay normally closed contact |
| NO1 | Relay normally open contact |
| CM1 | Relay common terminal |
5.3 Wiring Diagrams
Ensure correct wiring between the VFD and the spindle motor. Refer to the diagrams below for specific connections based on your voltage and control type.



5.4 External Terminal Control Wiring
The VFD supports various external control methods. Below are common wiring configurations:
5.4.1 Panel Control Wiring

5.4.2 Three-Wire Control Wiring

5.4.3 High, Medium, and Low Multi-Speed Control Wiring

5.4.4 Analog Quantity Control Wiring

5.4.5 External Potentiometer with Switch Control Wiring

6. Operation
6.1 Trial Run
Before operating the VFD and spindle, perform the following checks:
- Verify that the power supply is correctly connected to the N/L terminals, not the U.V.W terminals.
- Ensure no metal chips or wires are remaining on the inverter substrate or wiring terminals that could cause short circuits.
- Confirm all screws are tightly locked and connectors are secure.
- Check that the output part has no short circuit or ground fault.
Each time you press the STOP button, the cooling fan will run for about 30 seconds to allow you to observe its working status.
6.2 Parameter Setting Method
To set parameters on the VFD:
- Press the PRGM key until the inverter displays "Pyy.xx" to enter the parameter setting state. (yy = parameter group number, xx = parameter number).
- Use the ▲ or ▼ keys to select the desired parameter group and number.
- Press the SET key to enter the parameter value setting state.
- Use the ▲ or ▼ keys to modify the parameter value.
- Press the SET key again to save the modified parameter value.
- Press the PRGM key to exit the parameter setting state.
Note: Parameters can only be modified when the inverter is stopped (RUN light is off). If the parameter table is locked (P00.13=1), parameters can only be viewed, not modified.
6.3 VFD Parameter Table
The following table lists key parameters for the VFD. Refer to the full PDF manual for a complete list and detailed descriptions.
| Parameter Number | Name | Setting Range and Meaning | Factory Default |
|---|---|---|---|
| P00.00 | Main digital frequency | 0.0-600.0HZ | 400.0HZ |
| P00.01 | Start/stop command source | 0: Operate by panel; 1: External terminal (STOP effective); 2: External terminal (STOP invalid); 3: Modbus RS485 | 0 |
| P00.04 | VF curve: maximum output frequency | 1.0-600.0HZ | 400.0HZ |
| P00.05 | VF curve: output frequency at maximum voltage | 5.0-600.0HZ | 400.0HZ |
| P00.13 | Parameter recovery/locking/read and write | 0: Allow set; 1: Forbid set (locked); 10: Restore factory defaults | 0 |
| P03.09 | Panel potentiometer, upper limit of frequency setting | 0-120HZ (400HZ) | 400Hz |
| P07.07 | 8th section frequency setting | 0.0-600.0HZ | 400.0HZ |
Note: If you need to restore factory settings, set P00.13 to 10, press the confirm key, then turn off the power supply and wait for the inverter lights to go out before powering on. Otherwise, the restoration will be unsuccessful.
If you need to modify parameters, you must set the inverter in a non-working state (RUN light is off). After setting, turn off the power and wait for the inverter lights to go out before powering on, otherwise the setting will be unsuccessful.
7. Maintenance
7.1 Cooling System
The spindle motor features an eddy current air cooling system for continuous operation. The VFD also has a cooling fan.
- Fan Operating Mode (P12.11):
- Start the fan when the motor is running; after the motor stops, turn off the fan with a delay of about 1 minute.
- When the temperature is higher than the fan action temperature point (P12.12), the fan will be started immediately; when the temperature is lower than the fan action temperature point, the fan will be turned off after a delay of about 1 minute.
- Unconditionally force the fan to start.
- The fan does not work.
- Heat Sink Over Temperature Protection Point (P12.08): Default is 80.

7.2 General Maintenance Tips
- Regularly check for loose connections and tighten them as necessary.
- Keep the spindle motor and VFD clean and free from dust and debris.
- Inspect the bearings periodically. Bearings have a service life and may need replacement after 0.5 to 1 year depending on frequency and intensity of use.
8. Troubleshooting
This section provides common fault information and troubleshooting methods. If the issue persists, contact technical support.
| Error Code/Fault | Phenomenon | Analysis and Solutions |
|---|---|---|
| Er.00 | Power failure, power supply voltage is lower than 140VAC | 1. Check input power voltage (150-250V). Too high voltage damages inverter. 2. For large inertia load, increase deceleration time. |
| Er.01 | Power supply voltage is higher than 290VAC, or internal bus voltage is too high | 1. Inaccurate voltage detection by inverter (requires maintenance). 2. For large inertia load during deceleration, consider external braking resistor. |
| Er.02 | The current is too large | Check for motor short-circuit, correct connection, or excessive mechanical load. Maintenance may be required. |
| Er.03 | External PWM circuit error | Internal PWM circuit error. Turn off power for 1 minute, then retry. If persistent, maintenance is required. |
| Er.04 | IPM alarm (short circuit) | 1. Internal power unit module error. 2. Acceleration/deceleration time too short. 3. Inverter overcurrent/overheated. 4. Input voltage too high/low or fluctuates. 5. Inverter/motor power mismatch or incorrect star/delta wiring. 6. Incorrect DC braking parameters. 7. Incorrect VF parameters. 8. Cooling fan damaged/blocked. 9. Gate drive voltage too high/low. |
| Er.05 | External fault signal is input | Motor stops, displays code. Reset to clear. No maintenance required. |
| Er.06 | Internal data storage error | Error in internal data parameter storage. Turn off power for 1 minute, then test. |
| Er.07 | Over temperature | 1. Inverter internal temperature too high (>65°C). 2. Cooling fan not running. 3. Motor short-circuited or overloaded. 4. Poor heat conduction. |
| Er.08 | NTC temperature measurement error | Inverter internal temperature detection circuit or sensor faulty. Requires repair. |
| Er.10 | Power down prompt | Check input power voltage is within range. |
| Er.11 | RS485 communication is disconnected and error occurs, and the machine stops. | Related to parameters P03.03, P03.04. |
| Er.15 | Motor overheated | Refer to Er.07 solutions. |
9. User Tips
- Spindle Speed: This is a high-speed spindle. Avoid prolonged operation at low speeds. It is best to operate at or near its rated speed for optimal performance and longevity.
- VFD Parameter Adjustment: If you need to adjust VFD parameters, refer to the provided video demonstrations for guidance. Users have reported successful parameter adjustments for specific applications like aluminum alloy processing by following video instructions.
- Continuous Operation: The spindle is designed for continuous operation. If the ambient temperature is within the normal range (-10°C to +50°C) and the spindle surface temperature remains below 150°C, it can work continuously without interruption.
- Bearing Maintenance: If you notice abnormal sounds from the spindle, it is likely due to bearing issues. Bearings are wear-and-tear components and typically need replacement every 0.5 to 1 year, depending on usage frequency and intensity.
- Power Supply: Ensure your power supply (110V, 220V, or 380V) matches the VFD and spindle requirements. The kit is designed for plug-and-play use in various regions.
10. Warranty and Support
10.1 Warranty Information
The VFD comes with a 1-year warranty from the date of purchase.
10.2 Braking Resistor Policy
Please select the resistance and frequency of use specified by our company. If you use braking resistors and brake modules not provided by our company, and this causes damage to the inverter or other equipment, our company will not be held responsible.
10.3 Customer Support
For any further questions, technical assistance, or to inquire about specific braking resistor configurations, please contact your local dealer or the HLTNC Official Store.