COXO CX207-F

COXO Dental LED High Speed Handpiece User Manual

Model: CX207-F Series

1. Introduction

This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your COXO Dental LED High Speed Handpiece, CX207-F series. Please read this manual thoroughly before initial use and keep it for future reference.

Product Overview

The COXO Dental LED High Speed Handpiece (CX207-F series) is a professional dental instrument manufactured by the COXO factory under the YUSENDENT brand. It features a self-powered air turbine with integrated LED illumination, designed for precision dental procedures. Key features include German-made air turbine bearings for low noise and durability, a well-balanced cartridge/rotor, and a convenient push-button bur changing mechanism.

Available Models

  • CX207-F-SP-B2: Standard head and Borden 2-hole connection
  • CX207-F-SP-M4: Standard head and Midwest 4-hole connection
  • CX207-F-TP-B2: Torque head and Borden 2-hole connection
  • CX207-F-TP-M4: Torque head and Midwest 4-hole connection
Four COXO Dental LED High Speed Handpieces showing different head types and connector configurations (2-hole and 4-hole), along with detailed views of the cartridge dimensions and connector types.
Figure 1: Overview of COXO Dental LED High Speed Handpiece models and components.

2. Safety Information

This device is intended for use by qualified healthcare professionals only. Adhere to all local and national regulations regarding dental equipment operation and sterilization.

  • Always wear appropriate personal protective equipment (PPE) during operation.
  • Ensure the handpiece is securely connected to the dental unit before use.
  • Do not operate the handpiece if it shows signs of damage or malfunction.
  • Follow proper sterilization protocols before and after each patient use.
  • Use only compatible dental burs and ensure they are correctly inserted and locked.

3. Setup and Installation

Unpacking

Carefully unpack the contents of the box. The packing list includes:

  • 1 x COXO Dental LED High Speed Handpiece (CX207-F series)
  • 1 x Storage Box
  • 1 x Wrench Part (for maintenance/bur changing if not push-button)

Connecting the Handpiece

  1. Identify the correct connector type on your dental unit (2-hole Borden or 4-hole Midwest).
  2. Align the handpiece connector with the corresponding port on the dental unit hose.
  3. Push firmly until the handpiece is securely seated. For 2-hole and 4-hole connections, ensure the air and water lines are correctly aligned.
Close-up view of a 2-hole Borden type connector on the dental handpiece.
Figure 2: 2-Hole Borden Connector.
Close-up view of a 4-hole Midwest type connector on the dental handpiece.
Figure 3: 4-Hole Midwest Connector.

Bur Insertion

  1. Ensure the handpiece is disconnected from the air supply or the foot pedal is not engaged.
  2. Press the push-button cap at the back of the handpiece head.
  3. Insert the dental bur fully into the chuck.
  4. Release the push-button cap to lock the bur in place. Gently pull on the bur to confirm it is securely locked.
Close-up view of the handpiece head with the push-button cap for bur insertion/removal.
Figure 4: Handpiece head with push-button for bur insertion.

4. Operating Instructions

Initial Check

  • Before each use, verify that the bur is securely fastened.
  • Check for proper air and water spray function. The handpiece features 6 sprays (3 air, 3 water) for optimal cooling and debris removal.
  • Confirm the LED light is functioning. The handpiece has a built-in electric generator that powers the LED using air pressure.
Close-up of the handpiece head showing the integrated LED light.
Figure 5: Handpiece head with LED illumination.

Operation

  1. Activate the dental unit's foot pedal to initiate air flow to the handpiece.
  2. The handpiece will begin to rotate, and the LED light will illuminate.
  3. Adjust air pressure and water flow as needed via the dental unit controls.
  4. Apply gentle, controlled pressure during dental procedures.
  5. After use, release the foot pedal to stop rotation and turn off the LED.

5. Maintenance and Sterilization

Cleaning

  1. Immediately after each use, remove the bur.
  2. Wipe the exterior of the handpiece with a soft cloth dampened with a suitable disinfectant solution.
  3. Clean the spray nozzles with a cleaning wire if necessary to prevent clogging.

Lubrication

  • Lubricate the handpiece regularly according to the manufacturer's recommendations for dental handpiece oils.
  • Apply lubricant to the air drive tube and the bur chuck.
  • Run the handpiece briefly after lubrication to distribute the oil.

Sterilization

The handpiece is designed for steam sterilization (autoclaving). Follow these steps:

  1. Clean and lubricate the handpiece as described above.
  2. Place the handpiece in a sterilization pouch.
  3. Autoclave according to the sterilizer manufacturer's instructions (typically 135°C / 275°F for 20 minutes).
  4. Allow the handpiece to cool completely before handling or storage.

Cartridge/Rotor Replacement

The handpiece cartridge/rotor is a precision component balanced by a German balancing machine. If replacement is necessary due to wear or damage, use only genuine replacement parts.

Image of a standard rotor cartridge for the dental handpiece, showing its internal components.
Figure 6: Rotor Standard Cartridge.

6. Troubleshooting

Problem Possible Cause Solution
Handpiece not rotating No air supply; clogged air line; damaged turbine. Check dental unit air supply; clean air line; contact service for turbine replacement.
Weak or no water spray Clogged water line/nozzles; insufficient water pressure. Clean spray nozzles with cleaning wire; check dental unit water supply.
LED light not working Insufficient air pressure for generator; faulty generator/LED. Ensure adequate air pressure; contact service if problem persists.
Excessive noise or vibration Worn bearings; unbalanced rotor; bent bur. Lubricate handpiece; replace bur; contact service for cartridge replacement.
Bur not locking securely Damaged chuck; incorrect bur size. Ensure correct bur size (standard FG burs); contact service for chuck repair/replacement.

7. Specifications

Feature Detail
Brand YUSENDENT (manufactured by COXO)
Model Series CX207-F
Head Type Options Standard (SP), Torque (TP)
Connection Type Options Borden 2-hole (B2), Midwest 4-hole (M4)
Spray System 6 Spray (3 Air, 3 Water)
Illumination Integrated LED, self-powered by electric generator (air pressure)
Bearings German-made air turbine bearings
Cartridge Balancing Germany balancing machine
Bur Changing Mechanism Push-button cap
Certification CE
Origin Mainland China
Package Dimensions (approx.) Length: 18 cm, Width: 8 cm, Height: 3 cm
Package Weight (approx.) 0.2 kg

8. User Tips

  • Regular lubrication is crucial for extending the lifespan of your handpiece and maintaining optimal performance.
  • Always ensure the bur is fully seated and locked to prevent accidents during operation.
  • If experiencing reduced spray, check and clean the spray nozzles thoroughly before assuming a larger issue.
  • Store the handpiece in its protective box when not in use to prevent damage.

9. Warranty and Support

The handpiece cartridge/rotor comes with a one-year warranty. For warranty claims, technical support, or service, please contact your authorized dealer or the manufacturer directly. Ensure you retain your proof of purchase.

Disclaimer: This item may be intended for use by professional health care providers only. The seller may ask you to provide evidence that you are a qualified health care provider and are entitled to buy and use certain items in your country.

Related Documents - CX207-F

Preview COXO CX207 High-Speed Dental Turbine Handpiece User Manual
This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of the COXO CX207 series high-speed dental turbine handpiece. It covers technical specifications, assembly, usage guidelines, and warranty information.
Preview COXO CX235 Serie Håndstykker - Betjeningsmanual
Omfattende betjeningsmanual for COXO CX235 serien af dentale håndstykker, der dækker installation, brug, vedligeholdelse, fejlfinding og sikkerhedsprocedurer for professionelle tandplejere.
Preview COXO CX235 Series Contra Angle Operation Manual
Comprehensive operation manual for COXO CX235 Series Contra Angle dental handpieces. Includes technical specifications, usage instructions, maintenance, lubrication, sterilization, and troubleshooting.
Preview COXO C-SMART Mini User Manual - Dental Endo Motor
Comprehensive user manual for the COXO C-SMART Mini wireless endodontic motor. Includes operating instructions, features, safety guidelines, and electromagnetic compatibility (EMC) specifications according to IEC 60601-1-2.
Preview COXO CX235 Contra Angle Operation Manual - Dental Handpiece Guide
Comprehensive operation manual for the COXO CX235 Contra Angle dental handpiece, covering specifications, usage, maintenance, sterilization, and troubleshooting.
Preview COXO C-Smart Nova Endo Motor User Manual - Dental Equipment Guide
Comprehensive user manual for the COXO C-Smart Nova dental endo motor. Learn about safety, operation, maintenance, troubleshooting, and EMC compliance for this professional dental instrument.