1. Product Overview

The XYS3580 is a high-quality electronic component module designed for DIY electronic projects, industrial control equipment, portable devices, and precision electronic products. It features a compact size, stable performance, easy installation, and low power consumption.

This voltage Buck-Boost power supply integrates analog adjustment with digital control, allowing real-time viewing of preset voltage/current, input/output voltage, current, power, capacity, energy, and operation time. The output voltage remains stable whether the input voltage is lower than, equal to, or higher than the output voltage. It offers simple operation, high precision, stable performance, and a wide range of applications.

XYS3580 DC-DC Buck Boost Converter front view with display
Front view of the XYS3580 DC-DC Buck Boost Converter, showing the digital display and control knob.

2. Safety Warnings

⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

  • Professional operation is recommended. Avoid touching circuit pins or interfaces during operation to prevent electric shock or module damage.
  • Ensure input voltage/current matches the module's rated parameters. Do not overload or exceed the maximum rated value.
  • Keep away from water, moisture, high temperature, flammable materials, and strong electromagnetic interference sources.
  • Do not disassemble, modify, or repair the module without permission. Disconnect all power supplies before wiring or maintenance.
  • Avoid short circuits of pins or interfaces. Reverse connection of positive and negative poles may cause burnout or fire hazard.
  • For battery-related applications: Use only compatible battery types (e.g., Li-ion) to avoid explosion or leakage.

3. Installation & Wiring

3.1. Pin & Interface Definition

Interface/PinLabelFunction
VIN+VIN+Input Voltage Positive
VIN-VIN-Input Voltage Negative
OUT+OUT+Output Voltage Positive
OUT-OUT-Output Voltage Negative
XYS3580 DC-DC Buck Boost Converter rear view showing fan and terminals
Rear view of the module, highlighting the input (VIN) and output (OUT) terminals and cooling fan.

3.2. Wiring Steps

Follow these steps for safe installation and wiring (professional operation recommended):

  1. Disconnect all power supplies before wiring to avoid electric shock or module damage.
  2. Connect the power supply, load, or battery to the corresponding pins/interfaces according to the pin definition (avoid reverse connection).
  3. Check wiring carefully to ensure no short circuit, reverse connection, or loose contact.
  4. After confirming the wiring is correct, connect the power supply; the module will work normally.

3.3. Dimensions

XYS3580 DC-DC Buck Boost Converter dimensions diagram
Dimensions of the XYS3580 module (approx. 79mm x 42mm x 22mm).

4. Operation

4.1. General Usage Guidelines

  • Do not exceed the module's rated parameters (voltage, current, power) during use to avoid damage.
  • Keep the module in a well-ventilated environment; slight heating during operation is normal (if overheated, disconnect power immediately).
  • Use the module in corresponding scenarios based on its function (e.g., as a power supply, battery charger, or LED driver).

4.2. Interface and Key Functions

Product structure and features diagram
Diagram showing the HD LCD display, encoding potentiometer, ON/OFF button, integrated frosted panel, cooling fan, and output filtering.
Power main interface display details
Detailed view of the main display interface, indicating output voltage, current, power, temperature, CV/CC mode, ON/OFF status, and set voltage/current.
  • ON/OFF Button: Short press to toggle power output. Long press for 2 seconds to rotate the screen 360° (four-way rotation).
  • Encoding Potentiometer: Turn to quickly navigate pages.
  • Parameter Setting:
    • Short press the potentiometer key to activate the parameter (voltage/current) to be set.
    • Short press again to switch between full selection and bit selection.
    • When 'all' is selected, the blue display will be reversed; rotate the encoder to switch the set voltage/current.
    • After bit selection, the corresponding bit will be displayed in reverse blue; rotate the encoder to set parameters.
    • Long press the potentiometer key for 2 seconds or more, or wait for automatic exit after no key operation, to save settings.

4.3. Special Features

4.3.1. Temperature Measurement

Temperature measurement display (Celsius and Fahrenheit)
The display shows temperature in Celsius or Fahrenheit. Ambient temperature is measured when idle, module temperature when operating.

4.3.2. Night Rest Screen Mode

Night rest screen mode display
The module supports a night rest screen mode, indicated by a moon icon. The screen can be set to turn off after 1-10 minutes and wake up with any key press.

4.3.3. Voltage Current Curve Interface

Voltage current curve interface display
The display can show a voltage/current curve, with each grid representing 0.1V/0.01A.

4.3.4. Capacity Recording Interface

Capacity recording interface display
The capacity recording interface displays accumulated capacity (AH), energy (WH), time, input voltage, output voltage, and output current.

4.3.5. System Parameter Setting Interface

System parameter setting interface display
The system parameter setting interface allows adjustment of brightness (BL0-BL5), night mode rest time, Celsius/Fahrenheit switch, temperature correction value, and theme background/foreground colors.
Detailed view of the system parameter setting interface
Detailed view of the system parameter setting interface, showing options for brightness, night mode, temperature correction, and theme colors.

4.4. Application Examples

4.4.1. Common Voltage Regulator

The XYS3580 can be used as a common voltage Buck-Boost power supply with built-in over-voltage, over-current, over-power, over-temperature, and under-voltage protection.

XYS3580 used as a common voltage regulator
Example setup using the XYS3580 as a voltage regulator, connected to a CNC power supply and a USB smart load.

4.4.2. Battery Charger

The product has a constant current function, allowing it to charge rechargeable batteries within the 0.6V~36V range.

Charging Steps:

  1. Determine the floating charge voltage and charging current of your rechargeable battery (e.g., 4.2V for a 3.7V lithium battery, ~14V for a 12V rechargeable battery).
  2. Under no-load condition, set the output voltage to the determined floating charge voltage.
  3. Set the charging current (constant current value) directly.
  4. Connect the battery for charging.

Note: When charging the battery, ensure the positive and negative poles are not connected in reverse, as this can damage the product!

XYS3580 used as a battery charger
Example setup using the XYS3580 to charge a rechargeable battery.

4.4.3. LED Driver

The product's constant current function can directly drive 0.6-30V, 0-15W LED lamps. It can adjust the constant current value (between 0 - working current) to achieve stepless dimming without stroboscopic effects.

LED Driving Steps:

  1. Determine the working current and maximum working voltage of the LED you need to drive.
  2. Under no-load condition, set the voltage and current values to reach the LED's maximum working voltage and current. (Note: Calculate the power when setting the current; operate within the power range to avoid protection mode).
  3. Connect the LED and test the setup.
XYS3580 used for LED dimming
Example setup using the XYS3580 to drive and dim an LED lamp.

4.5. Data Group Function

Power parameter setting interface display
Power parameter setting interface, showing options for storage data groups, setting voltage/current, and various protection parameters.

The module can save 10 sets of data groups (M0-M9). M0 is saved by default. Long press the encoding potentiometer key for 2 seconds on any interface to quickly recall M1/M2 data groups. The current data group's serial number will be displayed at the interface index.

  • In the power parameter setting interface, select the data group and rotate the encoding potentiometer to recall the corresponding data group.
  • After modifying parameters within a data group and exiting, the changes will be stored in the current data group by default.
  • Note: Power output is off by default after data group switching.

4.6. Protection Settings

The XYS3580 includes several protection mechanisms:

  • Input Undervoltage Protection (LVP): Default 4.8V (user-settable).
  • Output Overvoltage Protection (OVP): Default 37V (user-settable).
  • Output Over-current Protection (OCP): Default 5.2A (user-settable).
  • Output Over Power Protection (OPP): Default 81W (user-settable).
  • Maximum Operation Time (OHP): If not set to 0, this function turns off output when operation reaches the set time.
  • Maximum Capacity (OAH): If not set to 0, this function turns off output when accumulated capacity reaches the set parameter.
  • Maximum Energy (OWH): If not set to 0, this function turns off output when accumulated energy reaches the set parameter.

The OHP / OAH / OWH functions enable precise timing and quantitative power supply control.

5. Maintenance

To ensure the longevity and optimal performance of your XYS3580 module, follow these maintenance guidelines:

  • Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Ensure adequate ventilation around the module, especially during prolonged operation, to prevent overheating.
  • Regularly inspect wiring connections for tightness and integrity to prevent intermittent operation or damage.
  • Store the module in a dry, cool environment away from direct sunlight and extreme temperatures.

6. Troubleshooting

  • No function/output: Check power supply, wiring connection, pin definition, and input parameters.
  • Unstable performance: Ensure input voltage is stable, avoid overload, poor contact, and electromagnetic interference.
  • Module overheating: Reduce load, improve ventilation, or check for short circuits.
  • Abnormal noise/indicator: Keep away from interference sources, check wiring tightness, and module damage.
  • Module stops working: Disconnect power first, check wiring and parameters, then restart after troubleshooting.

7. Specifications

ParameterValue
Model NumberXYS3580
Brand NameLiludin
TypeVoltage Regulator
PackageSMD
Input VoltageDC 6.0V ~ 36V (limit low 5.5V, limit high 38V)
Output VoltageDC 0.6V ~ 36V
Output Current0.000A ~ 5.000A
Output Power80W
Input Current LimitMax 7A
Voltage Resolution0.01V
Current Resolution0.001A
Voltage Accuracy±0.3% + 1 byte
Current Accuracy±0.4% + 3 bytes
Capacity Range0 - 999999AH
Energy Range0 - 999999WH
Time Range0 - 1000 hours
Is CustomizedYes
Dissipation PowerStandard
Supply VoltageAdjustable
ApplicationComputer
OriginMainland China
ConditionNew
Operating TemperatureStandard

8. Warranty & Contact

8.1. Warranty Information

The product comes with a 12-month warranty, covering manufacturing defects only. This warranty excludes man-made damage, overload, improper use, or operation errors.

8.2. Manufacturer Contact

  • Telephone: 86-13147003747
  • Email: jiaweinuokeji@163.com
  • Address: 2C056B, Zhonghang Road Metropolitan Electronic City, Huaqiangbei Street, Futian District, Shenzhen, Shenzhen Guangdong Province, China, Postcode: 518000

8.3. EU Authorized Representative (Compliance Responsible Person)

  • Company: APEX CE SPECIALISTS LIMITED
  • Telephone: 353-2066339
  • Email: INFO@APEX-CE.COM
  • Address: UNIT 3D NORTH POINT HOUSE NORTH POINT BUSINESS PARK NEW MALLOW ROAD CORK T23 AT2P, IRELAND

8.4. Additional Resources

A detailed user manual in PDF format is available for download. This document provides comprehensive instructions and specifications for the XYS3580 module. You can access it via the following link: XYS3580 User Manual (PDF).

9. User Tips

  • Adjustability: The module features an adjustable and variable output, making it versatile for various projects requiring precise voltage and current control.
  • Battery Charging Safety: Always double-check the polarity when connecting batteries for charging. Incorrect polarity can lead to immediate damage to the module.
  • Power Calculation: When setting current for loads like LEDs, always calculate the required power and ensure it stays within the module's rated power range to prevent the device from entering protection mode.
  • Short Circuit Prevention: Be extremely careful to avoid accidental short circuits, as the module can be sensitive to such events.