RuoShui 4090

RuoShui 4090 Digital LCR Meter User Manual

Model: 4090 Series

Brand: RuoShui

1. Introduction

The RuoShui 4090 series desktop LCR meter is a high-precision instrument designed for measuring capacitance, resistance, impedance, and inductance. It features a 3.5-inch TFT display, a user-friendly interface, and a variety of measurement parameters. This device is ideal for laboratories, factories, radio hobbyists, and educational settings, offering remote control capabilities via USB and RS232, as well as component sorting functions. With a basic accuracy of 0.2%, it provides reliable and precise measurements for various electronic components.

RuoShui Benchtop Digital LCR Meter with key features highlighted

Figure 1: RuoShui Benchtop Digital LCR Meter with key features.

2. Key Features

  • Measurement frequency up to 100kHz.
  • Adjustable test level from 100mV to 2000mV.
  • Supports measurement of DC resistance and electrolytic capacitors.
  • Internal bias voltage output (1mV-1500mV).
  • Automatic identification of component types for measurement.
  • 3.5-inch TFT display with 5 and a half digits resolution.
  • USB and RS232 communication interfaces for remote control.
  • Handler interface for component sorting.
  • Data recording function (maximum, minimum, and average values).
  • Supports SCPI communication protocol.
  • Customizable system settings including language, buzzer, and screen brightness.
  • Basic accuracy of 0.2%.
  • Manual and automatic ranging.
  • Open circuit and short circuit correction functions.
  • Comparator with sorting and alarm functions.
  • Multiple test ports for versatile connections.

3. Package Contents

Upon unpacking, please verify that all items listed below are present and in good condition:

  • Digital LCR Meter (Main Unit)
  • Three-core Power Cord
  • Four-terminal Pair Kelvin Test Cable
  • Product Manual
  • Fuse
Packaging accessories for the LCR meter

Figure 2: Included packaging accessories.

4. Product Overview

4.1. Front Panel

Front panel of the LCR meter with labeled controls

Figure 3: Front Panel Layout.

  1. 3.5-inch TFT Display: Shows measurement results and settings.
  2. Switch Key: Used for navigating menus and changing settings.
  3. Arrow Keys: For navigation and value adjustment.
  4. Basic Measurement Function Keys: Buttons for various measurement modes (e.g., AUTO, COMPARE, SAVE, TOL%, HOLD, DCR, MAX, MIN, AVG).
  5. Power Switch Key: Turns the device on/off.
  6. Ground Port: For grounding the instrument.
  7. Test Clip Jacks: Connectors for Kelvin test cables.

4.2. Rear Panel

Rear panel of the LCR meter showing Handler, RS-232, USB interfaces, Voltage jack, and Voltage selection switch

Figure 4: Rear Panel Layout.

  1. HANDLER Interface: For connecting to external sorting devices.
  2. RS-232 Interface: For serial communication with a computer.
  3. USB Interface: For USB communication and software upgrades.
  4. Voltage Jack: Power input connector.
  5. Voltage Selection Switch: To select between 110V and 220V power input.

4.3. Dimensions

Front view of the LCR meter with dimensions

Figure 5: Device Dimensions.

The approximate dimensions of the LCR meter are 265mm (width) x 305mm (depth) x 105mm (height).

5. Setup

5.1. Adjusting the Handle

To adjust the handle, hold the handles on both sides of the unit and pull them outward. Then, rotate the handle to the desired position for optimal viewing or portability.

Image demonstrating how to adjust the handle of the LCR meter

Figure 6: Handle Adjustment.

5.2. Power Connection

Connect the provided three-core power cord to the voltage jack on the rear panel. Ensure the voltage selection switch is set to the correct voltage (110V or 220V) for your region before powering on the device.

5.3. Connecting Test Leads

Plug the Kelvin test cables into the corresponding color-coded ports on the front panel. Ensure a secure connection for accurate measurements.

5.4. Calibration

Before taking measurements, it is crucial to perform open circuit and short circuit calibrations for accuracy.

5.4.1. Open Circuit Calibration

  1. Ensure no test clips are connected to each other or to any component.
  2. Press the AUTO/R/C/L/Z button to select the desired measurement mode.
  3. Press and hold the CAL button for 3 seconds to initiate open circuit calibration. The display will show "OPEN" during this process.

5.4.2. Short Circuit Calibration

  1. Clip the test clips together as shown in the diagram, ensuring the two test clips are placed on the same side of the wired connection.
  2. Press and hold the CAL button for 3 seconds to initiate short circuit calibration. The display will show "SHORT" during this process.

Video 1: How to Use RuoShui 4090 LCR Meter (Demonstrates test wire connection, open/short circuit calibration, and measurements).

5.5. Backlight Brightness Setting

To adjust the display backlight brightness:

  1. Turn on the device and enter the measurement display interface.
  2. Press the SET key to enter the system setting interface.
  3. Use the Up and Down arrow keys to navigate the cursor to "Brightness Adjustment".
  4. Use the Left and Right arrow keys to switch the backlight brightness (options: 30%, 50%, 70%, 100%).
Instructions for backlight brightness setting on the LCR meter

Figure 7: Backlight Brightness Setting.

6. Operation

6.1. Basic Measurement

After proper setup and calibration, connect the component to be measured using the Kelvin test clips. The device will automatically identify the component type and display the primary and secondary parameters on the 3.5-inch TFT screen.

6.2. Measurement Speeds

The LCR meter offers three measurement speeds to suit different needs:

  • FAST: 10 times/second
  • MID: 5 times/second
  • SLOW: 2 times/second
Image showing quick measurement speeds: Fast, Mid, Slow

Figure 8: Measurement Speed Options.

6.3. Data Logging Function

The instrument includes a data recording function that allows you to capture maximum, minimum, and average measurement values. This feature can operate with automatic or locked ranges.

Image illustrating the data logging function (MAX, MIN, AVG)

Figure 9: Data Logging Function.

6.4. Automatic Component Recognition

The LCR meter automatically identifies the type of component being measured, simplifying the measurement process. It also supports comparator sorting and list scanning for efficient component management.

Image showing automatic component recognition and calibration functions

Figure 10: Automatic Component Recognition.

7. Communication Interfaces

The RuoShui 4090 LCR Meter offers versatile communication options for integration with computers and other systems.

  • RS232 Interface: Supports SCPI communication protocol for remote control and data transfer.
  • USB Interface: Allows for plug-and-play USB storage device connectivity, software upgrades, and communication with a computer for remote control.
  • Handler Interface: Facilitates connection to external sorting devices for automated component testing and classification.
Image showing the USB computer connection and RS232 communication

Figure 11: Bridge and Computer Connection.

Image illustrating USB software upgrade and remote control capabilities

Figure 12: USB Software Upgrade and Remote Control.

8. Specifications

FeatureVC4090AVC4090BVC4090CVC4091AVC4091C
DigitsMain parameter: 5 digits; secondary parameter: 5 digits
Measurement ParameterMain parameter: L/C/R/Z; secondary parameter: X/D/Q/θ/ESR
Measurement Range (L)0.001μH - 9999H
Measurement Range (C)0.001pF - 9999μF
Measurement Range (R)0.0001Ω - 99.99MΩ
Basic Accuracy0.10%
Test Frequency (Hz)100~10kHz100~20kHz100~100kHz10~10kHz10~100kHz
10 points12 points16 pointsContinuously adjustable (1Hz)
Measurement Speed2 times/second (slow), 5 times/second (medium), 10 times/second (fast)
Internal Bias0-1500mV adjustable, 1mV stepping
Test Level100mV, 300mV, 600mV, 1000mV, 1500mV, 2000mV0.1V~2V Continuously adjustable (1mV)
Correction FunctionOpen circuit correction, short circuit correction
Screening FunctionThe screening limit can be set from -100% to +100%
with fixed points of 10%, 25%, 50%
Selection of ComparatorFive gear sorting, third gear qualified, one gear failed, one ancillary gear
Communication InterfaceStandard configuration: USB, RS232 (or 485), Handle interface;
Optional: GPIB, USB Host
OtherSupport DCR, electrolytic capacitor measurement mode, adjustable backlight brightness, optional in English and Chinese
PowerAC 200-240V 50-60Hz
FuseAC 250V 500mA
Working Environment(0-40)℃, relative humidity <80%
Storage Environment-10-50℃, relative humidity <80%
Size (W x D x H)265mm x 305mm x 105mm
Weight<2kg
Power Consumption<10W

9. Maintenance

To ensure the longevity and optimal performance of your RuoShui 4090 Digital LCR Meter, please follow these maintenance guidelines:

  • Cleaning: Regularly clean the exterior of the instrument with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the casing or display.
  • Storage: Store the device in a clean, dry environment within the specified storage temperature and humidity ranges (-10-50℃, relative humidity <80%).
  • Power: Always ensure the correct voltage is selected (110V/220V) before connecting to power.
  • Fuses: The device uses an AC 250V 500mA fuse. If the fuse needs replacement, ensure you use a fuse with the identical specifications.
  • Batteries: This device is mains-powered and does not use internal batteries for operation, thus no battery maintenance is required.
  • Handling: Handle the instrument with care to prevent physical damage.

10. Troubleshooting

This section provides solutions to common issues you might encounter with your LCR meter.

  • No Power:
      - Check if the power cord is securely connected to both the instrument and the power outlet.
      - Verify that the voltage selection switch on the rear panel matches your local power supply (110V/220V).
      - Check the fuse. If blown, replace it with a fuse of the same rating (AC 250V 500mA).
  • Inaccurate Measurements:
      - Ensure that open circuit and short circuit calibrations have been performed correctly before measurement.
      - Check that the Kelvin test cables are properly connected and not damaged.
      - Make sure the component is securely connected to the test clips.
      - Verify that the measurement frequency and test level settings are appropriate for the component being tested.
  • Display Issues:
      - If the display is too dim or bright, adjust the backlight brightness through the system settings (refer to Section 5.5).
      - If the display is blank or frozen, try restarting the instrument.
  • Communication Problems (USB/RS232):
      - Ensure the correct drivers are installed on your computer.
      - Check the physical cable connections.
      - Verify that the communication settings (e.g., baud rate) on both the instrument and the computer are correctly configured.

If you encounter an issue not listed here or if the problem persists after attempting these solutions, please contact customer support.

11. Warranty and Support

11.1. Warranty Information

RuoShui (Victor) instruments are guaranteed to be 100% genuine and original. All products come with a 1-year warranty from the date of receipt. Accessories are covered by a 3-month warranty. This warranty does not cover items damaged due to misuse or improper handling.

Defective items must be reported and returned within the warranty period, preferably in their original packaging.

11.2. Customer Support

Should you encounter any problems with your RuoShui 4090 Digital LCR Meter, please contact our customer support team. We are committed to providing the best possible solution to ensure your satisfaction.

12. User Tips

  • For highly accurate measurements, always perform both open circuit and short circuit calibrations before testing components, especially when changing test leads or measurement frequencies.
  • Utilize the data logging function (MAX, MIN, AVG) for analyzing component stability or variations over time.
  • When measuring very small or very large values, consider using the appropriate measurement speed (FAST for quick checks, SLOW for higher precision).
  • Keep the instrument's communication interfaces (USB, RS232) clean and protected when not in use to ensure reliable connectivity.

Related Documents - 4090

Preview Ruoshui 4091C 10Hz-100kHz LCR Meter - Technical Specifications and Product Information
Detailed specifications, features, and product information for the Ruoshui 4091C 10Hz-100kHz LCR Meter, a versatile instrument for electrical measurements.
Preview RuoShui 6801 Digital Thermometer Operation Manual
This manual provides detailed information on the operation, features, and specifications of the RuoShui 6801 digital thermometer, a 3 1/2 digit K-type thermocouple thermometer.
Preview Alphacool Eisblock Aurora Geforce RTX 4090 Strix/TUF Water Cooler - Technical Data & Compatibility
Detailed specifications, compatibility list, and scope of delivery for the Alphacool Eisblock Aurora water cooler designed for ASUS Geforce RTX 4090 Strix and TUF graphics cards. Features chrome-plated copper, optimized fin structure, and digital aRGB illumination.
Preview Módulo Endereçável Individual Simplex 4090-9007 IDNet para Sinalização de Alarme de Incêndio
Este documento técnico detalha o Módulo Endereçável Individual (IAM) Simplex 4090-9007 IDNet, projetado para fornecer sinalização adicional em painéis de controle de alarme de incêndio Simplex séries 4007ES, 4008, 4010ES, 4100ES e 4100U. Inclui características, recursos de supervisão, detalhes de operação, especificações elétricas e mecânicas, requisitos de fiação e informações de montagem para otimização de sistemas de alarme de incêndio.
Preview Módulo Direccionable Individual Simplex 4090-9007 IAM de Señal para Paneles de Alarma de Incendios
Descubra el Módulo Direccionable Individual (IAM) de Señal Simplex 4090-9007, un periférico IDNet para paneles de control de alarma de incendios 4007ES, 4008, 4010ES, 4100ES y 4100U. Proporciona señalización selectiva, supervisión de NAC, control de audio y cumple con UL, ULC, CSFM y FM.
Preview Alphacool Eisblock Aurora GeForce RTX 4090 AMP with Backplate Water Cooler
Detailed information on the Alphacool Eisblock Aurora water cooler for the GeForce RTX 4090 AMP Extreme AIRO, Trinity OC, and Trinity graphics cards. Features include optimized fin structure, chrome-plated copper, digital aRGB illumination, and high-performance thermal paste.