1. Introduction and Overview
This manual provides detailed instructions for the setup, operation, and maintenance of the HX711 Load Cell AD Intelligent Weight Pressure Sensor Module with Display. This 24-bit high-precision module is designed for various weighing display applications, including weighing indicators, process control instruments, and tensile testing machines.
The module can display the weight sensor's analog signal and maintain communication with a computer or PLC, meeting automatic control requirements. It is suitable for weighing, mechanical strength tests, and other measurement occasions.
The A/D, memory, and communication chips used are selected from top electronic device manufacturers, ensuring strong anti-interference ability, powerful functions, simple operation, strong versatility, small temperature drift, and high linearity. It can be widely used in industrial weighing applications.

2. Safety & Warnings
- Warning: Keep the device and its cord out of reach of children under 3 years old.
- Keep away from children unless supervised by an adult.
- Do not use this product for purposes other than its intended use.
- Inspect the product before each use; do not use if damaged.
- Follow installation and operation guidelines to avoid injury.
- Do not expose to water or moisture.
3. Product Information
- Product Name: HX711 Load Cell AD Intelligent Weight Pressure Sensor Module with Display 24-bit Weighing Instrument Electronic Scale 4P Cable
- Model: HX711 Load Cell AD Intelligent Weight Pressure Sensor Module with Display 24-bit Weighing Instrument Electronic Scale 4P Cable
- Batch/Serial Number: 1005001593599693
4. Setup & Installation
4.1. Wiring Diagram
Proper connection of the HX711 module to the load cell is crucial for accurate measurements. Refer to the wiring diagram below for correct connections.

4.2. Power Supply
The module supports power supply via a Micro Android interface or a 3.5mm plug (DC3.5mm power line). Ensure a 5VDC power supply is used.

4.3. Initial Calibration
Upon first power-up, calibration is required for accurate weight display. Without calibration, the weight display will be inaccurate.
Watch the video below for a visual guide on the calibration process.
5. Operating Instructions
5.1. Key Functions
- Setting Key: Used for parameter setting. In the setting state, it stores the new setting value and moves to the next parameter.
- Shift Key: In the setting state, press to set the corresponding value. In the working state, press and hold for 3 seconds to perform tare (peel) function.
- Add Key: Increases the set value in the setting state. In the working state, press and hold for 3 seconds to calibrate full-scale.
- Decrease Key: Decreases the set value in the setting state. In the working state, press and hold for 3 seconds to calibrate the zero point.
5.2. Parameter Setting
To enter parameter setting mode, use the Setting key. The following parameters can be configured:
- dot (Decimal point position): Range 0-3. For example, if the sensor range is 0-20Kg, it can be set to 2. Default: 1.
- ad-h (Acquisition speed): Range 1-100 times/second. Default: 20.
- ts (Regular data send interval): Range 0-10.0 seconds. If set to 0, data is sent when the weight changes, as fast as 3 times per second. Default: 0.5 seconds.
- en-b (Calibration entry): When set to ON, press the calibration key for 3 seconds to enter calibration. When set to OFF, press for 10 seconds. Default: ON.
- ini (Restore factory settings): Default is OFF. When set to ON, factory settings are restored. Default: OFF.
5.3. Calibration Procedures
Calibration is essential for accurate measurements. For example, if calibrating a 100kg sensor:
- Zero Calibration: Press and hold the Decrease Key for 3 seconds. The screen will display "-PL-". Release the key. Ensure no weight is on the scale. Input "0" on the module and press the Setting Key to confirm. The display will show "-End" when zero calibration is complete.
- Full-Scale Calibration: Press and hold the Add Key for 3 seconds. The screen will display "-PH-". Release the key. Place a known standard weight (e.g., 5kg, 20kg, up to 100kg) on the scale. Input the exact weight value (e.g., "5.00" for 5kg) on the module and press the Setting Key to confirm. The display will show "-End" when full-scale calibration is complete.
- Tare (Peeling): To tare, ensure the zero point is calibrated first. In the working state, press and hold the Shift Key for 3 seconds. This will set the current weight as zero, effectively removing the weight of the container or initial load.
Note on Zero Point Calibration: Zero point calibration does not necessarily refer to a true zero load. It can be calibrated with a tare weight. For instance, if the sensor range is 100kg and there's an unknown tare weight, you can calibrate PL=0.0Kg. If a known tare weight of 3Kg is present, you can calibrate PL=3.0Kg. After adding a 35kg load, calibrate PH=35.0Kg (or 38.0Kg if tare was 3Kg).
6. Maintenance & Care
To ensure optimal performance and longevity of your HX711 module, follow these maintenance guidelines:
- Implement routine maintenance protocols to uphold product standards.
- Periodic inspections are encouraged to ensure ongoing compliance with quality expectations.
- Store the module in a dry place.
- Keep the module away from children.
- Avoid exposing the module to extreme temperatures, humidity, or vibration.
- Protect against electromagnetic interference, static electricity, and pulse groups.
7. Troubleshooting
- Inaccurate Weight Display: Ensure the module has been properly calibrated (zero and full-scale). If not calibrated, the weight display will be inaccurate. Re-perform the calibration steps as described in Section 5.3.
- No Display/Power Issues: Verify that the power supply is correctly connected and providing 5VDC. Check the Micro Android interface or 3.5mm plug connection.
- Unstable Readings: Check for any external vibrations or electromagnetic interference in the environment. Ensure the load cell is securely mounted and not experiencing any mechanical stress other than the intended load.
- Communication Issues: If connecting to a computer or PLC, ensure the serial port settings (baud rate, etc.) match the module's configuration.
8. Specifications
| Feature | Description |
|---|---|
| Type | Voltage Regulator |
| Condition | New |
| Application | Computer, Weighing Indicator, Process Control, Tensile Testing |
| Display | 4 digital tubes (decimal point settable, automatic displacement) |
| Keyboard | 4 keys |
| Power Supply | 5VDC (Micro Android interface or 3.5mm plug) |
| Measurement Signal Range | ± 19mV |
| Temperature Coefficient | ≤100ppm / ℃ |
| A/D Conversion Rate | 6.25 ~ 100Hz (default 30) |
| Operating Temperature Range | -40 ℃ ~ + 70 ℃ |
| Storage Temperature Range | -60 ℃ ~ + 90 ℃ |
| Dimensions (L×W×D) | 55 × 35 × 12 mm |
| Number of Sensors Supported | 4 x 350Ω load cells |
| Dissipation Power | Low |
| Package | Module |
| is_customized | Yes |
9. User Tips
- This module offers digital output and customization options, making it versatile for various projects.
- It functions as both a weight sensing and pressure sensor, belonging to the acceleration sensor category.
- The module can be used with multiple load cells in a bridge configuration, supporting a total weight of up to 200 kg.
- It is compatible with various sensor capacities, such as 50kg sensors, allowing for flexible application.
- Remember that the HX711 chip can be either built-in or external, depending on the module variant. Both types are shown in the demonstration video.


10. Compliance Information
10.1. CE Marking
This product conforms to the following EU Directives:
- 2014/35/EU (Low Voltage Directive)
- 2014/30/EU (Electromagnetic Compatibility Directive)
10.2. RoHS Declaration
This product is in compliance with Directive 2011/65/EU and its amendment (EU) 2015/863, concerning the restriction of hazardous substances (Pb, Cd, Hg, etc.) in electrical and electronic equipment.
11. Manufacturer & Support
11.1. Manufacturer Information
- Company Name: Shenzhen ZhengYi Electronic Technology Co., Ltd
- Full Address: Jia An Road XA 41 D3-6F, Bao An District, ShenZhen, Guangdong Province, China
- Email: 1020636662@qq.com
11.2. EU Authorized Representative
- Company Name: eVatmaster Consulting GmbH
- Full Address: Raiffeisen Street2 B11, 63110 Rodgau, Hessen, Germany
- Email: contact@evatmaster.com
11.3. Disclaimer & Support
The manufacturer assumes no liability for outcomes resulting from non-compliance with these instructions, improper use, or unauthorized modifications. Specifications are subject to change without prior notice.
For further details, consult the official documentation or contact our support team.