JUNCTEK DPS3806

Contents

JUNTEK DPS-3806 DC Buck-Boost Power Supply Module

Model: DPS3806 | Brand: JUNCTEK

1. Introduction and Overview

The DPS3806DC-DC NC BOOST Buck Module is a compact, high-power, and highly efficient digital control module designed for precise voltage and current regulation. It features a digital display and is stable across various input voltage conditions, whether the input is lower, higher, or equal to the output voltage.

Utilizing advanced microprocessors, the module accurately adjusts output voltage and current. It includes 10 groups of storage locations for saving and recalling parameters, enhancing convenience. The four high-brightness LED digital display provides real-time information on voltage, current, power, and capacity. The device also offers automatic output and parameter display functions, which can be toggled as needed.

Key Characteristics:

  • Precise output voltage and current regulation using advanced microprocessors.
  • Memory function to store and recall 10 parameter groups.
  • User-friendly all-digital display.
  • Supports both constant voltage (CV) and constant current (CC) operating modes.
  • Four high-brightness LED displays for real-time output voltage, current, power, and capacity.
  • Automatic or manual switching of displayed parameters.
  • Indicators for OUT (output), CV (constant voltage), and CC (constant current) to show real-time status.
  • Configurable automatic output upon power-up.
  • One-key function to save current voltage and current settings.

2. Package Contents and Inspection

Upon receiving your DPS3806 DC-DC NC BOOST Buck Module, please follow these steps to inspect the package and its contents:

  1. Check for transport damage: If the packaging (cartons or bubble bags) appears severely damaged, retain all packaging materials until the module and accessories have been thoroughly tested.
  2. Verify package completeness: The standard package includes:
    • DPS3806 DC-DC NC BOOST Buck Module (1 unit)
    • User Manual (PDF version) (1 copy)
    If any items are missing or do not match the description, please contact your vendor or the manufacturer.
  3. Inspect the machine: If the instrument shows any physical damage, does not function correctly, or fails initial tests, please contact your vendor or the manufacturer for assistance.

3. Technical Specifications

ItemParameter
Modular NatureNon-isolated buck
Input Voltage10V~40V
Input Current0~8A
Output Voltage0~38V
Output Current0~6A
Conversion EfficiencyUp to 80%
Working Frequency150KHz
Short Circuit ProtectionConstant Current
Operating Temperature-40°C ~ +85°C
Control MethodDigital Control + Digital Display
Voltage Regulator / Display Resolution0.01V
Power Display Minimum Resolution0.001W
Current Regulation / Display Resolution0.001A
Capacity Display Minimum Resolution0.001AH
Output Ripple≤50mV
Product Weight116g
External Dimensions (L×W×H)100×80×29mm
Package Weight170g
Package Dimension155×100×50mm

4. Module Overview and Components

The DPS3806 module features a clear layout with labeled input/output terminals, a digital display, and control buttons. Refer to the diagram below for component identification.

Front view of the DPS-3806 DC Buck-Boost Power Supply Module showing the digital display, control buttons, and input/output terminals.
Figure 4.1: Front view of the DPS-3806 Module
LabelDescription
1Positive electrode of input (IN+)
2Negative electrode of input (IN-)
3DC socket
4+12V Fan Interface
5Positive electrode of output (OUT+)
6Negative electrode of output (OUT-)
7Digital Display and Indicators
8Operation Buttons (SET, UP, DOWN, OK)

5. Setup and Connections

Before operating the module, ensure all connections are made correctly and securely. Incorrect polarity can damage the module.

  1. Input Connection: Connect your DC power source to the input terminals (IN+ and IN-). Ensure the input voltage is within the specified range of 10V to 40V. The maximum input current is 8A. Reversing the polarity will damage the module.
  2. Output Connection: Connect your load to the output terminals (OUT+ and OUT-). The module can provide an output voltage from 0V to 38V and an output current from 0A to 6A.
  3. Fan Connection (Optional): If enhanced heat dissipation is required, connect a +12V fan to the dedicated fan interface. This is particularly recommended for output currents above 5A.

6. Operation

The DPS3806 module offers two operating modes: Simple Mode (default) and Full Function Mode. The following instructions detail how to use both modes.

6.1 Simple Mode Instructions

  1. Initial Display: After power-on, the module defaults to displaying the voltage value (e.g., "00.00"). The decimal point for voltage is in the second decimal place.
  2. Switching Display: Press the SET button to toggle the display between voltage and current. When displaying current, the format will be "0.000", with the decimal point in the first decimal place.
  3. Adjusting Values: Use the UP (▲) and DOWN (▼) buttons to adjust the displayed voltage or current value. A short press provides fine adjustment, while a long press enables rapid adjustment.
  4. Saving Settings: After adjusting the desired voltage or current, press the SET button again. The display will briefly show "----" to indicate that the current settings have been saved to the default storage location (M0).
  5. Initiating Output: Once settings are saved, press the OK button to enable the output.
  6. Adjusting Output During Operation: While the output is active, you can still adjust the output voltage or current using the UP (▲) and DOWN (▼) buttons.
  7. Cycling Display During Output: In the output state, a short press of the OK button will cycle through displaying voltage, current, power, and capacity. A long press (3 seconds) of the OK button will activate automatic cycling of these parameters; press again to cancel.
  8. Turning Off Output: To turn off the output, press the SET button while in the output state.

6.2 Full Function Mode Instructions

The module has three special functions that are disabled by default. To enable them:

  1. Enabling Functions: Press and hold the OK button while powering up the module. The digital display will cycle through "--0-", "--1-", "--2-". Release the OK button when the desired function is displayed to toggle it on or off.
    • "--0-": Function 0 (Automatic output after power-on)
    • "--1-": Function 1 (Save/transfer parameters, display power and capacity)
    • "--2-": Function 2 (Automatic rotation of output parameters)
    The display will show "--y-" if the function is enabled, and "--n-" if it is disabled.
  2. Function 0: Automatic Output on Power-up: If enabled, the module will automatically start outputting with the last saved settings when powered on.
  3. Function 1: Parameter Storage and Recall: This function allows you to save and recall up to 10 groups of voltage and current parameters (M0-M9). Each storage location is independent.
    Example: To save 10V, 1.5A to storage location 1:
    • Set the voltage to 10.00V, then press SET to save.
    • Set the current to 1.500A, then press SET to save.
    • Press SET to cycle to "SA.-0" (Save Parameter). Use the UP/ DOWN buttons to change it to "SA.-1" (Save to location 1), then press OK.
    • To recall parameters from location 1, press SET to cycle to "Lo.-0" (Load Parameter). Use the UP/ DOWN buttons to change it to "Lo.-1" (Load from location 1), then press OK.
  4. Function 2: Automatic Parameter Rotation: If enabled, the output display will automatically cycle through voltage, current, power, and capacity without manual intervention.

6.3 Operation Demonstration Video

Video 6.1: Demonstration of the DPS-3806 module's operation and display functions.

7. Precautions

  • Always connect the input and output correctly, ensuring proper polarity. Reversing the polarity will permanently damage the module.
  • For output currents exceeding 5A, it is crucial to enhance heat dissipation. Consider using a cooling fan connected to the +12V fan interface.
  • When operating the module in boost mode or with high-power electrical appliances, if the output is not normal, first turn off any automatic output function. Then, press the OK button to enable voltage output before connecting the electrical appliances.

8. User Tips

  • For prolonged use at higher currents (above 5A), active cooling (e.g., a fan) is highly recommended to maintain optimal performance and module longevity.
  • Familiarize yourself with both Simple and Full Function modes to leverage the module's full capabilities, especially the parameter storage feature for recurring tasks.

9. Troubleshooting

  • No Output/Incorrect Voltage: Double-check all input and output wiring for correct polarity and secure connections. Ensure the input voltage is within the 10V-40V range. Verify that the output is enabled (press OK in Simple Mode).
  • Module Not Powering On: Confirm the input power source is active and connected correctly. Check for any signs of physical damage.
  • Overheating: If the module feels excessively hot, especially during high current operation, ensure adequate ventilation and consider adding a cooling fan, particularly if operating above 5A.
  • Display Issues: If the display is blank or erratic, try power cycling the module. If issues persist, refer to the full PDF manual for more detailed diagnostics.

10. Maintenance

To ensure the longevity and optimal performance of your DPS3806 module:

  • Keep the module clean and free from dust and debris.
  • Avoid exposing the module to excessive moisture or extreme temperatures outside its operating range (-40°C to +85°C).
  • Regularly inspect connections for looseness or corrosion.
  • Ensure proper ventilation, especially when operating at higher power levels.

11. Warranty and Support

11.1 Warranty Conditions

This instrument is covered by a one-year warranty from the date of shipment. During this period, the manufacturer will repair or replace the instrument as deemed appropriate. For service, please send the product to the manufacturer.

The following conditions are not covered under warranty:

  • Damage resulting from user operation error or improper maintenance.
  • Issues arising from unauthorized modifications to the instrument.

11.2 Contact Information

For technical support or warranty claims, please use the following contact details:

12. Full User Manual (PDF)