1. Product Overview
The SINOTIMER SVP-915A is an automatic over-voltage and under-voltage protector designed for single-phase AC 230V, 50/60Hz systems, with a rated working current of up to 63A or 80A (adjustable). It is primarily intended for residential household box entry or for protecting single-phase electrical equipment on distribution lines against over-voltage, under-voltage, or over-current conditions.
When the circuit experiences over-voltage, under-voltage, or over-current issues, the device instantaneously cuts off the power supply to protect electrical equipment from damage. It automatically restores power once the circuit voltage returns to normal levels.
The device features an LCD display that shows voltage, current, and energy (kWh) measurements. A green indicator signifies normal power supply, while a red indicator signals over-voltage or under-voltage conditions.

2. Key Features
- Over-voltage protection
- Under-voltage protection
- Over-current protection
- Automatic recovery function
- Real-time voltage display (voltage measurement)
- Real-time current display (current measurement)
- Energy (kWh) display (power consumption measurement)
- Adjustable over-voltage protection value
- Adjustable over-voltage recovery value
- Adjustable over-voltage protection action time
- Adjustable under-voltage protection value
- Adjustable under-voltage recovery value
- Adjustable under-voltage protection action time
- Adjustable over-current protection value
- Adjustable over-current protection action time
- Adjustable fault recovery delay time
- Adjustable power-on delay time
- Reset mode selection (Automatic/Manual)
- Fault inquiry function
- Factory settings restore option
3. Installation and Setup
3.1 Physical Installation
The SVP-915A is designed for 35mm DIN rail installation. Ensure the device is securely mounted in a suitable electrical enclosure.
3.2 Wiring Diagram
Connect the device according to the following wiring diagram. Ensure all connections are tight and correct to prevent electrical hazards.

3.3 Initial Power-On
When you first connect the product, you must wait approximately 1 minute. The device will initialize, and once the red indicator light turns off, the product will begin normal operation.
4. Operating Instructions
4.1 Setting Parameters
To adjust the protection parameters, follow these steps:
- Press and hold the SET button for 3 seconds to enter the setting mode.
- Continuously press the SET button to cycle through the adjustable parameters.
- Use the ▲ (Up) or ▼ (Down) buttons to adjust the value of the currently displayed parameter.
- Once you have finished adjusting all desired parameters, continue pressing SET until the LCD displays "END".
- Press SET one more time to save the settings. The device will exit the setting state and return to normal operation, displaying the current voltage.
4.2 Parameter Settings Table
| Step | LCD Display Content | Setting Item | Adjustable Range (Default) |
|---|---|---|---|
| 1 | SET and Uvo | Over-voltage protection value | 221V-300V-OFF (280V) |
| 2 | Uvor | Over-voltage recovery value | 221V-299V (250V) |
| 3 | Tdr | Over-voltage protection action time | 0.1s-10s (0.1s) |
| 4 | SET and Uvu | Under-voltage protection value | 150V-219V-OFF (160V) |
| 5 | Uvur | Under-voltage recovery value | 151V-219V (180V) |
| 6 | Tdr | Under-voltage protection action time | 0.1s-10s (0.2s) |
| 7 | 63 (or 80) | Over-current protection value | 1-63A or 1-80A (63A or 80A) |
| 8 | 5.0 | Over-current protection action time | 0.1s-512s (5.0s) |
| 9 | 60 | Recovery delay time | 2s-120s (60s) |
| 10 | 2 | Power-on delay time | 2s-10s (2s) |
| 11 | AU/HA | Reset mode selection | "AU" (Automatic Reset) / "HA" (Manual Reset) |
| 12 | E | Fault inquiry | Displays last 5 faults (Uov, Uvu, Io, IR) |
| 13 | END | End of settings | Press SET to save and exit. |
4.3 Switching Display Values
In the normal operating state (not in setting mode), press the ▲ or ▼ buttons to cycle through the displayed values (Voltage, Current, kWh).
5. Specifications
| Parameter | Value |
|---|---|
| Model Number | SVP-915A |
| Power Supply | 230VAC 50/60Hz |
| Max. Loading Current | 1~63A or 1~80A (Adjustable) |
| Rated Voltage | 220V |
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc |
| Certification | CE |
| Display | LCD Display (Voltage, Current, kWh) |
| Poles | 2 Poles |
| Installation | 35mm DIN rail |
| Dimensions | 36*65*83mm |
| Power Consumption | <2W |
| Electric Machinery Life | 100,000 times |
| Over-voltage protection value range | 221V~300V~OFF (Default: 280V) |
| Over-voltage recovery voltage range | 220V~299V (Default: 250V) |
| Over-voltage protection action time | 0.1s~10s (Default: 0.1s) |
| Under-voltage protection value range | 219V~150V~OFF (Default: 160V) |
| Under-voltage recovery voltage range | 151V~220V (Default: 180V) |
| Under-voltage protection action time | 0.1s~10s (Default: 0.1s) |
| Over-current adjustment range | 1-63A or 1-80A (Default: 63A or 80A) |
| Over-current action range | 0.1s~512s (Default: 5.0s) |
| Recovery delay time | 2s~120s (Default: 60s) |
| Power-on delay time | 2s~10s (Default: 2s) |
6. Maintenance
6.1 Restoring Factory Settings
To restore the device to its default factory settings:
- Press and hold both the ▲ and ▼ buttons simultaneously for 3 seconds.
- The LCD screen will flash once, indicating that the default parameter values have been restored.
7. Troubleshooting
7.1 Fault Inquiry
The device can display the last 5 fault events. To inquire about faults:
- Enter the setting mode by pressing and holding SET for 3 seconds.
- Cycle through the settings using the SET button until "E" is displayed on the LCD.
- Press the ▲ button to view the last 5 recorded faults.
Fault codes and their meanings:
- Uov: Over-voltage event
- Uvu: Under-voltage event
- Io: Over-current event
- IR: Bad load event (if applicable to model variant)
8. User Tips
- Initial Connection Delay: Remember to wait approximately 1 minute after initial power-on for the device to stabilize and the red indicator light to turn off before expecting normal operation.
- Customizing Protection: Take advantage of the adjustable parameters for over-voltage, under-voltage, and over-current protection to tailor the device's response to your specific electrical system and connected equipment.
- Monitoring: Regularly check the LCD display for real-time voltage, current, and kWh readings to monitor your electrical consumption and system health.
9. Warranty and Support
For detailed information regarding warranty, service, and technical support, please refer to the official documentation provided by SINOTIMER. A user manual in PDF format is available for further reference: