1. Introduction
Thank you for choosing the S4A RFID Metal Access Control Keypad (Model SA-0103). This device provides a secure and convenient solution for managing access to your premises. Featuring a robust metal construction, support for RFID keytags/cards, and PIN code entry, it is designed for reliable operation. When installed outdoors, the included rainproof cover offers additional protection against environmental elements. This manual will guide you through the installation, operation, and maintenance of your access control system.
2. Specifications
| Feature | Description |
|---|---|
| Brand Name | S4A |
| Model Number | SA-0103 |
| Size | 120mm x 56mm x 18mm |
| Work Voltage | DC 12V |
| Static Current | ≤30mA |
| Reading Range | 3cm ~ 8cm |
| Capacity | 2000 users |
| Ambient Temperature | -25°C ~ 60°C |
| Ambient Humidity | 10% ~ 90% |
| Electric Lock Output | ≤3A |
| Alarm Output | ≤20A |
| Output Short Circuit Protection Time | ≤100μS |
| Open Time | 0 ~ 99 seconds (adjustable) |
Rainproof Housing Dimensions:
- Outer size: 150mm x 104mm x 90mm
- Inner size: 135mm x 89mm x 84mm



3. Package Contents
Your S4A RFID Metal Access Control Keypad package typically includes the following items:
- 1x S4A RFID Metal Access Control Keypad (Model SA-0103)
- 7x RFID Keytags or Thin Cards (quantity and type may vary based on purchase option)
- 1x Rainproof Housing (for outdoor installation)
- Mounting screws and wall plugs
- User Manual (this document)


4. Product Overview
The SA-0103 access control keypad is designed for durability and ease of use. Its metal casing provides enhanced security and longevity. The keypad features backlit buttons for visibility in low-light conditions, and LED indicators to show the system's status. A built-in doorbell function adds convenience.

5. Setup and Installation
Proper installation is crucial for the optimal performance and security of your access control system. It is recommended that installation be performed by a qualified technician.
5.1. Mounting the Keypad
- Choose a suitable mounting location near the door, ensuring it is easily accessible and within reach of necessary wiring.
- If installing outdoors, first mount the rainproof housing. The keypad is surface waterproof, but the housing provides additional protection against direct rain and harsh weather.
- Use the keypad dimensions (120mm x 56mm) and the rainproof housing dimensions (150mm x 104mm) as a guide for placement.
- Mark the drilling points on the wall using the keypad's backplate as a template.
- Drill holes and insert wall plugs if necessary.
- Secure the keypad to the wall using the provided screws.


5.2. Wiring Diagram
The keypad requires a DC 12V power supply and connects to an electric lock, an exit button, and optionally a doorbell. Follow the wiring diagrams carefully.


Wiring Connections:
- +12V and GND: Connect to a stable DC 12V power supply.
- LOCK: Connect to the electric lock. Ensure compatibility with your lock type (Normally Open - NO or Normally Closed - NC).
- REX/BL: Connect to the exit button.
- BELL1 and BELL2: Connect to an external doorbell.
- AUX_IN and AUX_OUT: Auxiliary input/output for advanced functions (refer to specific programming instructions for details).
- COM, NO, NC: These terminals are for connecting various types of electric locks. COM is common, NO (Normally Open) means the circuit is open when the lock is de-energized, and NC (Normally Closed) means the circuit is closed when the lock is de-energized. Choose the appropriate connection based on your lock's requirements.
Warning: Incorrect wiring can damage the device or connected components. Always ensure power is disconnected before performing any wiring.
6. Operating Instructions
The SA-0103 keypad supports multiple access methods and programming options.
6.1. Basic Operation
- Access with RFID: Present a programmed RFID keytag or card to the keypad. The door will unlock for the set open time.
- Access with PIN: Enter your programmed PIN code followed by the '#' key. The door will unlock for the set open time.
- Doorbell Function: Press the bell icon button on the keypad to activate the connected doorbell.
6.2. Programming Mode
To enter programming mode, you typically need to enter a master code. The default master code is often 123456 or 999999, but please refer to the specific programming guide that came with your unit for the exact default code and programming steps.
General Programming Steps (may vary slightly):
- Enter Programming Mode: Enter the Master Code, then press
#. The LED indicator will change (e.g., from red to green or flash). - Add User (RFID Card/Keytag):
- While in programming mode, enter the command for adding a user (e.g.,
1). - Present the new RFID card/keytag to the keypad.
- The keypad will beep to confirm successful addition.
- While in programming mode, enter the command for adding a user (e.g.,
- Add User (PIN Code):
- While in programming mode, enter the command for adding a user (e.g.,
2). - Enter the desired PIN code (4-6 digits), then press
#. - Re-enter the PIN code, then press
#again to confirm. - The keypad will beep to confirm successful addition.
- While in programming mode, enter the command for adding a user (e.g.,
- Delete User:
- While in programming mode, enter the command for deleting a user (e.g.,
3). - To delete by RFID: Present the RFID card/keytag to be deleted.
- To delete by PIN: Enter the PIN code to be deleted, then press
#. - The keypad will beep to confirm deletion.
- While in programming mode, enter the command for deleting a user (e.g.,
- Change Master Code:
- While in programming mode, enter the command for changing the master code (e.g.,
8). - Enter the new Master Code, then press
#. - Re-enter the new Master Code, then press
#again to confirm.
- While in programming mode, enter the command for changing the master code (e.g.,
- Adjust Open Time:
- While in programming mode, enter the command for adjusting open time (e.g.,
9). - Enter the desired open time in seconds (0-99), then press
#.
- While in programming mode, enter the command for adjusting open time (e.g.,
- Exit Programming Mode: Press
*or wait for a timeout.
Note: Always refer to the specific programming instructions provided with your device for exact commands and sequences.
7. Maintenance
- Cleaning: Wipe the keypad surface with a soft, damp cloth. Avoid using abrasive cleaners or solvents, as these can damage the finish and electronic components.
- Outdoor Protection: If installed outdoors, regularly check that the rainproof cover is securely in place and free from cracks or damage. Ensure no water can accumulate around the keypad.
- Wiring Inspection: Periodically inspect all wiring connections to ensure they are secure and free from corrosion or damage.
- Functionality Check: Test the keypad's functionality (RFID, PIN, doorbell, exit button) regularly to ensure it is operating correctly.
8. Troubleshooting
- Keypad is unresponsive: Check the power supply connection. Ensure the DC 12V power adapter is functioning and properly connected to the keypad's +12V and GND terminals.
- Door does not unlock after valid entry:
- Verify that the user's RFID card/PIN is correctly programmed.
- Check the wiring to the electric lock. Ensure it matches the lock type (NO/NC) and is securely connected.
- Confirm the 'Open Time' setting is not set to 0 or an extremely short duration.
- RFID card/keytag is not being read: Ensure the card is presented within the 3-8cm reading range. Check if the card is damaged or if it's a compatible type.
- Doorbell button does not work: Inspect the wiring to the external doorbell (BELL1 and BELL2 terminals). Ensure the doorbell itself is functional.
- Keypad beeps continuously or shows an error: This may indicate a tamper alarm or a system error. Refer to the specific programming guide for error codes or reset procedures. Disconnecting and reconnecting power can sometimes resolve temporary glitches.
- Keypad is not backlit: Check power supply and wiring. If the issue persists, there might be an internal fault.
9. User Tips
- Secure Your Master Code: Always change the default master code immediately after installation and keep the new code in a secure, memorable location.
- Outdoor Protection: For outdoor installations, even though the keypad is surface waterproof, always utilize the provided rainproof cover. This significantly extends the lifespan of the device by protecting it from direct exposure to rain and harsh weather conditions.
- Test Regularly: Periodically test all access methods (RFID, PIN) and the exit button to ensure the system is functioning as expected.
- Backup Access: Consider having a backup method of entry in case of power failure or system malfunction.
10. Warranty and Support
This S4A RFID Metal Access Control Keypad comes with a 2-year guarantee, ensuring quality and reliability. For technical assistance, troubleshooting beyond this manual, or to inquire about warranty claims, please contact your original vendor or the S4A customer support channel.