GEYA THC-822

Contents

GEYA THC-822 Conversational Programmable Timer Instruction Manual

Digital Timer Switch with 2 Channel Changeover Contacts

1. Product Overview

The GEYA THC-822 is a versatile conversational programmable digital timer switch designed for precise control of electrical circuits. It features two independent changeover contacts, a large LCD display, and supports programming for up to 44 ON/OFF events or pulse programs, and 18 cycle programs per week. The timer includes a built-in lithium battery to maintain settings during power outages.

Front view of GEYA THC-822 timer showing display and buttons with language options

Figure 1: Front view of the THC-822 timer, highlighting language selection and special functions.

2. Safety Information

Before installation or operation, please read this manual carefully. Ensure the power supply is disconnected before performing any wiring. Installation should be carried out by a qualified electrician in accordance with local electrical codes and regulations. Do not expose the device to moisture or extreme temperatures.

3. Installation and Wiring

3.1 Mounting

The GEYA THC-822 is designed for Din Rail mounting. Securely attach the timer to a standard 35mm DIN rail within an appropriate enclosure.

3.2 Wiring Diagrams

Ensure all connections are tight and correct to prevent malfunction or damage.

Wiring diagram for connecting a single load to the THC-822 timer

Figure 2: Wiring diagram for connecting a single load (e.g., a light bulb) to the timer. Connect the AC220V Live (L) and Neutral (N) to the timer's input terminals. The load is connected between the timer's output (C1, 1) and Neutral (N).

Wiring diagram for connecting two independent loads to the THC-822 timer

Figure 3: Wiring diagram for two independent loads. Each channel (C1, 1 and C2, 4) can control a separate load. Note: This is a special case, for reference only. Consult a professional for complex installations.

4. Initial Setup and Basic Operation

4.1 First Time Use (Reset)

When using the timer for the first time, or if the display is blank/unresponsive, press the 'RES' button (located in a small recess, may require a pointed object like a toothpick) to turn on the timer and reset all settings. This will clear all previous programs and reset the date/time.

4.2 Language Selection

  1. After resetting, the display will show 'ENGLISH'.
  2. Use the '+' or '-' buttons to cycle through the available languages: English, Portuguese, Italian, Spanish, German, French.
  3. Press the 'OK' button to confirm your desired language.
Instructions for choosing language and setting date on the THC-822 timer

Figure 4: Visual guide for language selection and initial date setting.

4.3 Setting Date and Time

  1. After selecting the language, the display will show '2007' (or the current year).
  2. Use the '+' or '-' buttons to adjust the year.
  3. Press 'OK' to confirm the year.
  4. Repeat this process for setting the month, day, hour, and minute.

4.4 Understanding the Display and Buttons

Detailed explanation of THC-822 timer display indicators and button functions

Figure 5: Detailed view of the LCD display and button functions.

  • Black Stripe Indicator: Indicates that the contacts are ON 24 hours a day.
  • 'AUTO' Display: Means the timer operates ON/OFF as programmed.
  • Internal Power Source Indicator: A specific icon indicates the timer uses its own power source (no output conversion).
  • External Power Source Indicator: A specific icon indicates the timer uses an external power source.
  • Menu Options: Includes 'PROGRAM', 'DATE/TIME', and 'MANUAL'.
  • 'Res' Button: Resets the date/time.
  • 'OK' Button: Confirms selection or enters the program key.
  • '+' Button: Adds value or changes options.
  • '-' Button: Reduces value or changes options.
  • Indicators: Icons for Daylight Saving Time, Winter Time, and Day of the Week.

5. Programming Instructions

The THC-822 offers various programming options for flexible control.

5.1 General Program Setting (ON/OFF)

The timer supports up to 44 ON/OFF programs with a minimum interval of 1 minute.

  1. Press the 'Menu' button once.
  2. Press 'OK' to confirm. The display will show 'CHANNEL 1'.
  3. Press 'OK' again. The display will show 'TIME ON'.
  4. Press 'OK' to enter the time setting.
  5. Use the '+' or '-' buttons to set the desired ON time (hour and minute), pressing 'OK' after each segment.
  6. Next, set the day(s) of the week for this program using '+' or '-' to select, then press 'OK'.
  7. The display will then show 'TIME OFF'. Repeat steps 4-6 to set the OFF time and day(s).
  8. Continue to set additional programs or exit by pressing 'Menu'.

5.2 Pulse and Cycle Programs

  • Up to 44 pulse programs can be set with a minimum interval of 1 second.
  • Up to 18 cycle programs can be set.

For detailed instructions on setting Pulse and Cycle programs, please refer to the comprehensive manual or contact customer support.

5.3 Summer and Winter Time Settings

  1. Press the 'Menu' button twice.
  2. Press 'OK' continuously until the display shows 'SUM/WIN'.
  3. Press 'OK'. The display will show 'NO SU/WI' or 'WITH S/W'.
  4. Use the '+' or '-' buttons to select 'WITH S/W'.
  5. Press 'OK' to confirm.
  6. Use the '+' or '-' buttons to select your region (there are 5 types to choose from).
  7. Press 'OK' to confirm your selection.

5.4 Special Functions

The THC-822 includes several special functions:

  • PULSE: For short, timed activations.
  • RANDOM: Randomizes ON/OFF times within a set window.
  • HOLIDAY: Allows for temporary program suspension during holidays.
  • CYCLE PROGRAM: Repeats ON/OFF cycles.
  • OVERRIDE: Temporarily overrides the current program to force ON or OFF.
  • PERM ON/OFF: Sets the output to permanently ON or OFF, ignoring programs.

For detailed setup of these functions, consult the full product manual.

Instructions for Summer/Winter time settings and general program setting on THC-822 timer

Figure 6: Visual guide for Summer/Winter time settings and general program setting.

5.5 Product Demonstration Video

Video 1: A demonstration of basic programming and reset functions of the GEYA THC-822 timer.

6. Maintenance

6.1 Battery Life

The built-in lithium battery can maintain the timer's settings for approximately four years at room temperature (20°C) without external power. While the control program remains active, the contact state will not change without external power. The battery is not user-replaceable.

6.2 Cleaning

Clean the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents.

6.3 Full Reset

Pressing the 'RES' button will perform a full reset, clearing all programmed settings, including date and time. This action cannot be undone.

7. Troubleshooting

7.1 Timer Not Responding / Blank Display

  • Ensure the timer is correctly wired and receiving power (AC220V or 110V, depending on model).
  • Press the 'RES' button to perform a hard reset.

7.2 Programs Not Activating

  • Verify that the current time and date are set correctly.
  • Check that the timer is in 'AUTO' mode, not 'PERM ON/OFF' or 'OVERRIDE'.
  • Ensure the program settings (ON/OFF times, days) are correctly entered and confirmed.
  • Confirm that the load is correctly wired and functional.

7.3 Language Issues

  • If the language is incorrect or difficult to understand, follow the language selection steps in Section 4.2.

8. Specifications

FeatureSpecification
Model NumberTHC-822 Timer Switch
TypeMini Digital Timer
Rated VoltageAC220V+10%~-15% or 110V
Rated Frequency50/60Hz
Power ConsumptionMax 7.5VA
Contact Capacity16A AC250V (cos Φ=1), 10A AC250V (cos Φ=0.6)
Switching Contact2 Changeover Switch (2NO2NC)
DisplayLCD
Maximum Programs44 (ON/OFF or Pulse)
Minimum Setting Time1 minute (ON/OFF), 1 second (Pulse)
Cycle ProgramsUp to 18
Storage Power (Battery)Lithium battery, approx. 4 years retention at 20°C
Ambient Temperature-10°C to +50°C
Storage Temperature-20°C to +65°C
Timing Accuracy±1 second per day (at 20°C)
MountedDin Rail
Supported LanguagesEnglish, Portuguese, Italian, Spanish, German, French
CertificationCE
Dimensions (H x W x D)86mm x 35.5mm x 65.5mm
Weight0.22 kg
Dimensions diagram of the GEYA THC-822 timer

Figure 7: Physical dimensions of the THC-822 timer.

9. User Tips

  • The timer is generally intuitive to operate, even without extensive manual reading.
  • The two independent channels offer great versatility for controlling different loads.
  • Ensure you press the 'RES' button upon first use to activate the timer and initialize settings.
  • Take advantage of the multiple language options for easier programming.

10. Frequently Asked Questions (FAQ)

Q: Can each contact be programmed independently?
A: Yes, each of the two channels can be programmed independently.
Q: What type of timer is this?
A: It is a Mini Digital Programmable Timer.
Q: What is the brand of this product?
A: The brand of this product is GEYA.

11. Warranty and Support

This product is CE certified, indicating compliance with European safety, health, and environmental protection requirements.

For a comprehensive manual, technical support, or any further assistance, please contact GEYA customer support through their official channels.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.