1. Introduction
The LILYTECH ZL-7802A Thermoregulator is a versatile device designed for precise control of both temperature and humidity. Its advanced features make it suitable for a wide range of applications requiring environmental parameter management.
Applications include:
- Cages, brooders, and other animal housing facilities
- Terrariums
- Greenhouses
- Vegetable storage
- Grow boxes
By simultaneously measuring temperature and humidity, the ZL-7802A acts as a unique and efficient controller. Please note that the firmware version may differ from "CO2" and "CO3" versions. Always check your device's firmware before configuration.
2. Key Features
- Simultaneous and highly accurate control of temperature and humidity.
- Operates in heating, humidifying, and dehumidifying modes.
- Additional timer function on a separate channel for controlling ventilation, watering, egg turning in incubators, or other custom tasks.
- Equipped with a new ultra-fast and accurate SHR04 series sensor.
- Includes an alarm output.
Differences from Model ZL-7801:
- Temperature Control Modes: Allows selection between PID algorithm (with adjustable parameters) or "Relay" mode via the deep settings menu.
- Independent Relay Inputs: Relays responsible for humidity regulation (R2) and timers (R1, R4+R5) have separate inputs. This simplifies connecting devices with different power voltages (e.g., 12V DC or 220V AC).
- Removable Terminal Blocks: Wires are attached to removable terminal blocks for easier installation and maintenance.
- Connectorized Sensor: The sensor connects via a dedicated connector, not individual wires.
- Included Fuse: A fuse for the heating element is included in the package.
- Heating Only: This model operates only in heating mode.
3. Setup and Installation
3.1 Physical Installation
The controller is designed for panel mounting. Ensure the cutting size for installation is 71 x 29 mm.
111.jpg)
3.2 Sensor Connection
The SHR04 temperature and humidity sensor connects to a dedicated port on the controller. Ensure the connector is securely seated.

3.3 Wiring Diagrams
The ZL-7802A features removable terminal blocks for easy wiring. The main terminal block is labeled for general connections, while a separate port is for the sensor, and a fuse holder is integrated for the heating element.

Below are fundamental electrical wiring diagrams for various applications:
Simplified Connection Diagram

Incubator Wiring with All 220V AC Elements (Figure 1 from original description)

- Relay 1 (Timer 1): Controls the ventilation fan motor (220V AC).
- Relay 2 (Humidity Sensor): Controls the humidifier fan motor (220V AC).
- Relay 3 (Timer 2 & 3): Controls a single-phase AC capacitor motor for egg turning, switching the capacitor winding to change rotation direction.
- Temperature-Humidity Sensor: Connects to its dedicated port.
- Right Terminal Block (Triac): Controls the heating element (TEN) power circuit. A fuse is included in this circuit for protection against overloads.
Incubator Wiring with Mixed 220V AC and 12V DC Power (Figure 2 from original description)

4. Operating Instructions
4.1 Initial Power-Up and Firmware Check
Upon initial power-up, the device will display its current readings. Before configuring, it is crucial to verify the firmware version, as settings may vary between versions (e.g., "CO2" and "CO3"). Refer to the detailed instruction manual for specific firmware configuration steps.
4.2 Setting Temperature and Humidity
The ZL-7802A allows precise setting of temperature and humidity parameters. The temperature setting range is -20°C to +120°C with a 0.1°C step, and the humidity setting range is 0% to 100% RH with a 0.1% step.
4.3 Temperature Control Modes (PID vs. Relay)
Through the deep settings menu, you can select the temperature control algorithm:
- PID Algorithm: Proportional-Integral-Derivative control offers precise and rapid temperature regulation. This mode allows for fine-tuning of PID parameters for optimal performance.
- Relay Mode: A simpler on/off control based on set thresholds.
The ZL-7802A utilizes a triac regulator for the heating element (TEN), enabling precise dosing of electrical power through pulse width modulation (PWM). This results in smooth and linear heat regulation. The triac works only with AC circuits, as its turn-off mechanism relies on the current passing through it becoming zero during an AC half-period.
4.4 Timer Function
An additional timer function is available on a separate channel. This can be configured for various tasks such as controlling ventilation fans, irrigation systems, or automatic egg turning in incubators.
4.5 Alarm Output
The device includes an alarm output to signal when parameters deviate from the set ranges, providing an alert for critical environmental changes.
5. Maintenance
- Keep the controller clean and free from dust and moisture. The front panel has an IP65 water resistance rating, but the entire unit is not waterproof.
- Regularly check all wiring connections for tightness and signs of wear.
- Ensure the sensor is clean and unobstructed for accurate readings. Avoid placing the sensor in direct contact with water or extreme temperatures beyond its operating range.
- If the heating element fuse blows, replace it with a fuse of the same rating (included in the package). This protects the internal triac from overload.
6. Troubleshooting
- No Power: Check the power supply (185-245V, 50Hz) and ensure all connections are secure. Verify the fuse for the heating element is intact.
- Inaccurate Readings: Ensure the SHR04 sensor is properly connected and not damaged. Check for any obstructions or extreme environmental conditions affecting the sensor.
- Control Malfunction: If the heating or humidity control is not working as expected, review the selected control mode (PID or Relay) and its parameters in the deep settings menu. Check the wiring of the controlled devices.
- Alarm Triggered: Identify which parameter (temperature or humidity) is outside its set range. Adjust settings or address the environmental condition causing the deviation.
- Triac Failure: If the heating element is not receiving power despite correct settings and an intact fuse, the internal triac might be damaged due to overload. Consult a specialist for repair.
7. Specifications
| Parameter | Value |
|---|---|
| Temperature Setting Range | -20 to +120 ℃ (0.1 ℃ step) |
| Humidity Setting Range | 0% to 100% RH (0.1% step) |
| Operating Temperature | -20 to +45 ℃ |
| Operating Humidity | 10 - 90% (non-condensing) |
| Water Resistance (Front Panel) | IP65 |
| Power Supply | 185 - 245 V AC, 50Hz |
| Load Current (Relays) | R1, R2: 2 x 5 A; R4+R5: 1 x 3 A |
| Load Current (Temperature Output) | 7 A (resistive load) |
| Dimensions | 78 x 35 x 71 mm |
| Accuracy | ±1 ℃ / ±3% RH |
| Sensor Type | SHR04 (2-in-1 temperature and humidity sensor) |
| Sensor Cable Length | 1.5 meters |
| Installation Cutout Size | 71 x 29 mm |
8. Package Contents
- LILYTECH ZL-7802A Thermoregulator
- SHR04 Temperature and Humidity Sensor
- Instruction Manual
- Fuse for heating element
9. User Tips
While no specific user reviews or Q&A were provided for this product, general tips for similar thermoregulators include:
- Calibration: If you suspect inaccurate readings, check the manual for any calibration options.
- Sensor Placement: Position the sensor away from direct heat sources, drafts, or areas where moisture might condense directly on it, to ensure the most accurate environmental readings.
- Power Backup: For critical applications like incubators, consider connecting the thermoregulator to an uninterruptible power supply (UPS) to maintain stable operation during power fluctuations or outages.
- Wiring Safety: Always ensure proper insulation and secure connections for all wiring, especially for 220V AC circuits. If unsure, consult a qualified electrician.
10. Support