KKMOON HT107D

Contents

KKmoon HT107D 90-250V Outlet Socket Tester User Manual

Automatic Electric Circuit Polarity Voltage Detector Breaker Finder

1. Introduction

The advanced KKmoon Socket Tester is designed to rapidly detect the correct wiring and connection polarity of electrical sockets. It also features a leakage tripping test function (RCD/GFCI) for enhanced safety. This professional tool helps ensure the safety of your electrical installations by identifying common wiring faults.

This manual provides detailed instructions for the HT107B (US Plug), HT107D (EU Plug), and HT107E (UK Plug) models.

Three KKmoon Socket Tester models: HT107B (US Plug), HT107D (EU Plug), HT107E (UK Plug)

Figure 1.1: Available Plug Types (US, EU, UK)

2. Safety Information

WARNING: Always exercise extreme caution when working with electricity. Improper use can lead to electric shock, injury, or death.

  • Ensure the tester is suitable for the voltage and current of the circuit you are testing.
  • Do not use the tester if it appears damaged or is not functioning correctly.
  • Keep hands and other body parts away from live electrical contacts.
  • When performing the RCD/GFCI test, be aware that it will trip the circuit breaker. Ensure all connected devices can safely handle a power interruption.
  • This device is for testing purposes only and should not be used as a substitute for professional electrical inspection.
  • The voltage displayed is for reference only and is not a high-accuracy digital measurement.

3. Product Overview

The KKmoon Socket Tester is a compact and lightweight device designed for ease of use. It features a clear LCD display and a series of LED indicators to provide immediate feedback on socket wiring status.

Key Components:

  • LCD Display: Shows L-N voltage, N-E voltage, and GFCI/RCD current.
  • LED Indicators: Six red LED lights indicate various wiring conditions.
  • RCD/GFCI Test Button: Used to test the functionality of residual current devices or ground fault circuit interrupters.
  • Plug Type: Available in US, EU, and UK plug configurations.
KKmoon Socket Tester HT107B (US Plug) showing LCD display and LED indicators

Figure 3.1: Front View of the Socket Tester (US Plug Model)

4. Specifications

FeatureDescription
Brand NameKKmoon
ColorBlack
ModelHT107B (US) / HT107D (EU) / HT107E (UK)
MaterialFlame Retardant ABS
Operating Voltage90~250V AC
Phase Voltage90~250V
Leakage Voltage0~99V
Accuracy± (2.0%+2)
RCD Test (EU/UK Plug)>30mA
RCD Working Voltage220V±20V
GFCI Test (US Plug)>5mA
GFCI Working Voltage110V±20V
Working Environment0℃ ~ 40℃, 20% ~75%RH
Storage Environment-10℃ ~ 50℃, 20% ~80%RH
Item Size68 * 65 * 60mm / 2.7 * 2.6 * 2.4in
Item Weight74g / 2.6oz
Package Includes1 * Electric Socket Tester

5. Setup

The KKmoon Socket Tester is designed for plug-and-play operation. No complex setup or calibration is required.

  1. Select the Correct Model: Ensure you have the appropriate plug type (US, EU, or UK) for your region.
  2. Inspect the Device: Before each use, visually inspect the tester for any signs of damage, such as cracks in the casing or frayed wires. Do not use if damaged.
  3. Prepare the Socket: Ensure the socket you intend to test is easily accessible and free from obstructions.

6. Operating Instructions

6.1 Basic Wiring Test

  1. Plug the KKmoon Socket Tester directly into the electrical outlet you wish to test.
  2. Observe the LED indicators on the front panel. The pattern of illuminated LEDs will indicate the wiring status of the socket. Refer to Section 7, "Interpreting Results," for a detailed explanation of each pattern.
  3. The LCD display will show the L-N (Live-Neutral) voltage, N-E (Neutral-Earth) voltage, and GFCI/RCD current (if applicable).

6.2 GFCI / RCD Test

The GFCI (Ground Fault Circuit Interrupter) or RCD (Residual Current Device) test function is crucial for verifying the safety features of your electrical system. This test simulates a ground fault to ensure the circuit breaker trips as expected.

KKmoon Socket Tester HT107B in use, highlighting the GFCI test button

Figure 6.1: Performing a GFCI/RCD Test

  1. Plug the tester into the socket.
  2. Ensure the wiring test (Section 6.1) shows a 'CORRECT' indication before proceeding with the GFCI/RCD test.
  3. Press the RCD/GFCI Test Button located on the front of the tester.
  4. If the GFCI/RCD is functioning correctly, the circuit breaker should trip, cutting power to the socket. The tester's lights will turn off.
  5. If the circuit breaker does not trip, the GFCI/RCD is faulty and should be inspected by a qualified electrician.
  6. To restore power, reset the circuit breaker.

Important: Do not touch the RCD/GFCI button unnecessarily, as it will trigger the leakage protection switch and cut power to the circuit.

7. Interpreting Results

The socket tester uses a combination of red LED indicators to display the wiring status. The patterns are typically labeled on the back of the device for quick reference.

Diagram showing LED indicator patterns for different wiring faults

Figure 7.1: LED Indicator Reference for Wiring Status

LED PatternWiring StatusAction Required
Two rightmost LEDs ONCORRECTWiring is correct.
Middle and rightmost LEDs ONOPEN GROUNDGround wire is disconnected. Consult an electrician.
Leftmost and rightmost LEDs ONOPEN NEUTRALNeutral wire is disconnected. Consult an electrician.
Leftmost and middle LEDs ONLIVE/GRD REVERSELive and Ground wires are reversed. Consult an electrician.
All three LEDs ONLIVE/NEU REVERSELive and Neutral wires are reversed. Consult an electrician.
Leftmost LED ONLIVE/GRD REVERSE; MISSING GRDLive and Ground wires are reversed, and ground is missing. Consult an electrician.

8. Troubleshooting

  • No lights or display when plugged in: Ensure the socket has power. Check the circuit breaker. If other devices work in the socket, the tester might be faulty.
  • Inconsistent readings: Ensure the tester is fully inserted into the socket. Try testing another known good socket to verify tester functionality.
  • GFCI/RCD test does not trip the breaker: If the wiring is indicated as 'CORRECT' but the GFCI/RCD test fails to trip the breaker, the GFCI/RCD outlet or breaker itself is faulty and requires immediate attention from a qualified electrician.
  • Voltage readings seem off: Remember that the voltage displayed on the LCD is for reference only and may not be highly accurate. For precise voltage measurements, use a dedicated multimeter.
Notice regarding voltage display accuracy on the socket tester

Figure 8.1: Important Notice on Voltage Display Accuracy

9. Maintenance

  • Cleaning: Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the tester in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Inspection: Periodically inspect the tester for any physical damage.
  • No User-Serviceable Parts: Do not attempt to open or repair the device. This will void any warranty and could lead to safety hazards.

10. Warranty and Support

KKmoon is committed to providing quality products. We strictly control quality problems before shipping to prevent outflow. If you encounter any product quality problems, you may be eligible for repair or exchange under the original condition.

If the product is damaged during transit, please contact the seller before opening any dispute or leaving negative feedback. The seller will endeavor to resolve the issue.

For further support or warranty claims, please refer to the contact information provided by your retailer or the official KKmoon support channels.

© 2023 KKmoon. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.