MESTEK IR05B

Contents

Mestek Dual Laser Infrared Thermometer User Manual

Model: IR05B

Brand: MESTEK

1. Introduction

The MESTEK IR05B is a high-precision dual-laser infrared thermometer designed for non-contact temperature measurement. It offers a wide temperature range, quick response time, and supports K-type thermocouple measurements for enhanced versatility. This manual provides essential information for the safe and effective use of your device.

Video: Product demonstration of the Mestek Infrared Thermometer.

2. Safety Information

WARNING: AVOID EXPOSURE. LASER RADIATION IS EMITTED FROM THIS APERTURE. DO NOT STARE INTO BEAM. CLASS 2 LASER PRODUCT.

Dual laser indication with caution label

Image: Close-up of the thermometer's laser apertures with a safety warning.

  • Do not aim the laser directly at eyes or indirectly through reflective surfaces.
  • Do not measure through transparent surfaces such as glass or plastic, as this will result in inaccurate readings.
  • If the ambient temperature changes significantly, allow the thermometer to acclimate for at least 30 minutes before use to ensure accuracy.
Product parameters table and precautions

Image: Product parameters table including important precautions.

3. Setup

3.1 Battery Installation

  1. Locate the battery compartment on the handle of the thermometer.
  2. Open the battery compartment cover.
  3. Insert two 1.5V AA batteries (not included), ensuring correct polarity.
  4. Close the battery compartment cover securely.
Quick measurement steps including battery installation

Image: Diagram showing battery installation and initial measurement steps.

4. Operating Instructions

4.1 Display Overview

Panel functions diagram with numbered labels

Image: Detailed diagram of the thermometer's display and button functions.

  1. Emissivity
  2. Measurement indication
  3. Laser indication
  4. Battery undervoltage indication
  5. Data locking (HOLD)
  6. Irradiation measurement temperature value
  7. Temperature unit (°C/°F)
  8. Maximum lock (MAX)
  9. Minimum lock (MIN)
  10. Average (AVG)
  11. Temperature difference value (DIFF)
  12. Alarm indication
  13. High alarm (HI)
  14. Low alarm (LOW)
  15. K-type thermocouple temperature

4.2 Basic Temperature Measurement

Point the thermometer at the target object. Press and hold the trigger to activate the laser and begin measurement. The current temperature will be displayed. Release the trigger to hold the reading on the screen.

One-click temperature measurement in an industrial setting

Image: Demonstrating one-click temperature measurement with quick response.

4.3 Distance-to-Spot (D:S) Ratio

The D:S ratio for this device is 50:1. This means that at a distance of 50 units, the measurement spot diameter will be 1 unit. For accurate readings, ensure the target object completely fills the measurement spot.

Distance-to-Spot ratio diagram

Image: Diagram illustrating the 50:1 Distance-to-Spot ratio for accurate positioning.

4.4 Celsius/Fahrenheit Switching

To switch between Celsius (°C) and Fahrenheit (°F) temperature units, press the dedicated °C/°F button on the control panel. This allows for real-time conversion based on your preference.

C/F switching buttons on the thermometer display

Image: Visual guide for switching between Celsius and Fahrenheit units.

4.5 Emissivity Adjustment

The emissivity (ε) can be adjusted from 0.1 to 1.0 to match the surface properties of the object being measured, ensuring higher precision. The default emissivity preset is 0.95.

To adjust emissivity: Press the SET button until the emissivity setting is active, then use the up/down arrow buttons to change the value. Short press the trigger to exit setup mode.

Adjustable emissivity feature with comparison table

Image: Emissivity adjustment feature and a comparison table for common materials.

Emission Rate Comparison Table
Substance Emissivity Substance Emissivity Substance Emissivity
Aluminium0.30Concrete0.95Iron0.70
Asbestos0.95Copper0.95Lead0.50
Asphalt0.95Oil sludge0.94Limestone0.98
Basalt0.70Frozen food0.90Paint0.93
Brass0.50Hot food0.93Paper0.95
Brick0.90Glass (board)0.85Plastics0.95
Carbon0.85Ice0.98Rubber0.95
Ceramics0.95Oil0.94Steel0.80

4.6 High and Low Temperature Alarm

The thermometer features configurable high and low temperature alarms. When the measured temperature exceeds the set high alarm value or falls below the set low alarm value, an alarm indicator will appear on the display.

To set alarm values: Long press the SET button to enter high temperature setting mode. Use the up/down arrow buttons to adjust the value. Gently press SET again to enter low temperature setting mode and adjust. Short press the trigger to exit setup mode.

Thermometer measuring food with high/low alarm active

Image: Example of the high and low temperature alarm in action while measuring food.

4.7 Measurement Value Modes (MAX/MIN/AVG/DIFF)

The device supports various measurement value modes including Maximum (MAX), Minimum (MIN), Average (AVG), and Temperature Difference (DIFF). You can toggle between these modes by lightly pressing the MIN/MAX button to view different statistical measurements of your readings.

Display showing Max, Min, Avg, Diff modes

Image: Display highlighting the Max, Min, Avg, and Diff measurement modes.

4.8 K-type Thermocouple Measurement

For contact temperature measurements, insert the K-type thermocouple plug into the designated socket on the thermometer. Ensure the thermocouple probe makes direct contact with the object to be measured. The K-type temperature range is -10~500°C (14~932°F).

K-type thermocouple connected to thermometer

Image: Demonstrating K-type thermocouple temperature measurement.

4.9 Sleep Mode (Automatic Shutdown)

To conserve battery life, the thermometer will automatically enter a sleep state after approximately 35 seconds of no operation.

Thermometer entering sleep mode after 35 seconds

Image: Illustration of the thermometer's automatic sleep mode feature.

4.10 Measurement Precautions

When measuring boiling liquids, avoid direct contact with smoke or steam. Maintain a measurement angle of approximately 45° to 60° in the temperature sensing area to prevent inaccurate readings and potential damage.

Correct and incorrect methods for measuring liquid temperature

Image: Visual guide for correct water/oil temperature measurement to avoid steam interference.

5. Maintenance

  • Keep the thermometer lens clean. Use a soft, damp cloth to wipe the surface. Do not use abrasive cleaners or solvents.
  • Store the device in a dry, cool environment when not in use.
  • Remove batteries if the device will not be used for an extended period to prevent leakage.

6. Troubleshooting

  • Device not powering on: Check if batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
  • Inaccurate readings: Verify the emissivity setting matches the material being measured. Ensure the measurement distance is appropriate for the 50:1 D:S ratio. Allow the device to acclimate to ambient temperature if there's been a sudden change.
  • Laser not working: Check battery level. If the issue persists, contact customer support.

7. Specifications

Product parameters table for IR05B

Image: Detailed product parameters table for the IR05B model.

Parameter Value
ModelIR05B
Temperature range-40~2000°C (-40~3632°F)
Accuracy-40°C~800°C (±1.5%), 800°C~2000°C (±3%)
K-type range-10°C~500°C (14°F~932°F)
K-type accuracy±(1.5%+2°C/4°F)
DisplayVA reverse display color screen
D:S50:1
Spectral response8-14um
Resolving power0.1°C/0.1°F
Emissivity0.10~1.00 adjustable
Laser<1mW / 620-690nm Level 2
Response time<0.5s
Automatic shutdownAbout 35 seconds
Usage environment0~50°C / 10%~90%RH
Storage temperature-20°C~60°C
Size180x120x60mm
Power source2x1.5V AA battery
WeightApproximately 265g (excluding battery)

7.1 Industrial Grade Components

The IR05B is built with high-quality industrial-grade components, including high-precision laser indication, high-precision sensors, an aluminum alloy sensing housing, and a high-speed intelligent chip, ensuring reliable performance and stability.

Diagram of industrial grade components

Image: Internal view highlighting the industrial-grade components of the thermometer.

7.2 Application Scope

This thermometer is suitable for a wide range of applications where surface temperature measurement is required, including:

  • Industrial processes (e.g., welding, mold/laser applications)
  • Steel/Smelting/Chemical industry
  • Glass/Ceramic field
  • Electric/mechanical temperature measurement
  • Heating/Ventilation/Air Conditioning (HVAC)
  • Kitchen and barbecue cooking
Various application scenarios for the thermometer

Image: Examples of various applications where the thermometer can be used.

8. User Tips

  • Humidity Measurement: This thermometer is designed for surface temperature measurement and does not measure humidity.
  • Effective Range: Always refer to the Distance-to-Spot (D:S) ratio (50:1) to ensure the target object is adequately covered by the measurement spot for accurate readings.
  • Audible Alarm: The device features high and low temperature alarms with on-screen indications, but it does not emit an audible beep or sound.
  • Measuring Electric Cables: Yes, it can measure the surface temperature of electric cables. Always ensure safety precautions are followed when working near electrical components.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the MESTEK Official Store or your authorized dealer. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.