1. Product Overview
The Lokey Smart 32S Ant BMS (Battery Management System) is designed to protect and manage Lithium, LiFePO4, and LTO battery packs ranging from 10S to 32S configurations. It features a common port design and includes Bluetooth App connectivity for monitoring and control. This BMS is available in various current ratings, with all 150A, 200A, and 300A models sharing the same compact size.

Figure 1: Main product view of the BMS board, showing its size (190x70x25mm) and compatibility with 10S-32S Lithium/Lifepo4/LTO batteries, and Bluetooth App support.
2. Specifications
| Attribute | Value |
|---|---|
| Brand Name | Lokey |
| Model Number | 32s 100-300A BMS |
| Accessory Type | Battery Accessories |
| Origin | Mainland China |
| Certification | CE |
| Compatible Cells | 10S to 32S Lithium, LiFePO4, LTO |
| Dimensions (L*W*T) | 190mm * 70mm * 25mm |
| Feature | Common port, Bluetooth App |
| Peak Current (BMS) | 150A / 200A / 300A |
| Continuous Current (Approx.) | 80A (for 200A peak), 100A (for 250A peak), 120A (for 300A peak) |
| Power Consumption (Standby) | 0.8 mAh |
| Power Consumption (Operational) | 2 mAh |
| Charger Included | No |
| Battery Included | No |

Figure 2: Physical dimensions of the BMS board (19cm length, 7cm width, 2.5cm thickness, 10cm wire length).
3. Setup and Wiring
Proper wiring is crucial for the safe and correct operation of the BMS. Please follow the diagrams carefully. Ensure all connections are secure and insulated to prevent damage to the board or battery pack.
3.1 General Wiring Diagram (32S Example)

Figure 3: Detailed 32S wiring diagram for the BMS, illustrating connections for load controller, charger, and individual cell balance wires (B+, B-, 1-32).
3.2 Specific Wiring Diagrams for Different Cell Counts
The BMS supports various cell counts from 10S to 32S. Below are examples for common configurations. Always ensure the balance wires are connected to the correct cell terminals (B- to the negative terminal of the first cell, B+ to the positive terminal of the last cell, and intermediate wires to corresponding cell positives).

Figure 4: Wiring diagram for a 10S battery configuration.

Figure 5: Wiring diagram for a 12S battery configuration.

Figure 6: Wiring diagram for a 13S battery configuration.

Figure 7: Wiring diagram for a 14S battery configuration.

Figure 8: Wiring diagram for an 8S battery configuration.
3.3 Display Screen Connection (Optional)
If you have an optional display screen, connect it as shown below. The power supply range for the display is 24V-150V. Ensure the black line is connected to the negative pole of the power supply and cannot be connected incorrectly.

Figure 9: Instructions for connecting an optional display screen, detailing power supply range and polarity.
Important: After all wires are connected, press and hold the switch to start up. The screen should show information after startup. Ensure proper insulation for all connections to prevent damage.
4. Operating Instructions
4.1 Bluetooth App
The BMS supports a Bluetooth App for monitoring and control. Once the BMS is powered on, connect to it via the dedicated Bluetooth application on your Android or Apple device. The app allows you to view battery status, cell voltages, and other parameters.
4.2 Indicator Lights and Power Consumption

Figure 10: Diagram explaining BMS operational indicators, including Bluetooth light behavior and power consumption.
- Working State: The BMS will always be 'on' when working.
- Standby State: The Bluetooth light flashes once every 4 seconds when the BMS is in standby mode.
- Transition: The Bluetooth light goes out when the BMS enters the charging and discharging mode, canceling standby.
- Power Consumption: 0.8 mAh in standby, 2 mAh during operational use.
5. Maintenance
To ensure the longevity and reliable performance of your Smart 32S Ant BMS, consider the following:
- Insulation: Always ensure all wiring connections are properly insulated to prevent short circuits and electrical damage.
- Environment: Operate the BMS within its specified temperature and humidity ranges. Avoid exposure to extreme conditions, moisture, or corrosive substances.
- Cleaning: Keep the BMS board clean and free from dust and debris. Use a soft, dry cloth for cleaning.
6. Troubleshooting
- BMS Not Powering On: Ensure all wires are correctly connected and insulated. Verify the power supply range (24V-150V for display, if applicable) and correct polarity. Press and hold the switch to initiate startup.
- Bluetooth Connectivity Issues: Check if the BMS is powered on and the Bluetooth light is flashing (indicating standby) or off (indicating active charging/discharging). Ensure your device's Bluetooth is enabled and within range.
- Board Damage: Any contact with electricity without proper insulation can damage the board. Always ensure all connections are insulated.
7. User Tips
- Insulation is Key: Always double-check and ensure all exposed wires and connections are properly insulated. This is critical for preventing short circuits and protecting the BMS.
- Optional Modules: Remember that UART box, 485 box, GPRS module (iron/plastic) are sold separately and are not included with the BMS. Plan your purchase accordingly if these features are desired.
- Current Ratings: Be aware that the advertised 150A/200A/300A ratings are peak currents. The continuous working current is lower (e.g., 80A for 200A peak BMS). Match the BMS to your battery pack's continuous discharge requirements.
8. Warranty and Support
For any technical assistance, warranty claims, or support inquiries, please contact the seller directly. Ensure you provide your purchase details and a clear description of the issue to facilitate a quick resolution.